Design of parallel flat-field gratings in soft X-ray region

被引:0
|
作者
Wang, Qingbo [1 ,2 ]
Liu, Zhengkun [1 ]
Chen, Huoyao [1 ]
Wang, Yu [1 ]
Fu, Shaojun [1 ]
机构
[1] National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei,Anhui,230029, China
[2] Department of Precision Machinery and Precision Instrumentation, School of engineering Science, University of Science and Technology of China, Hefei,Anhui,230027, China
来源
Guangxue Xuebao/Acta Optica Sinica | 2014年 / 34卷 / 08期
关键词
Holography - Aberrations - Genetic algorithms;
D O I
10.3788/AOS201434.0805001
中图分类号
学科分类号
摘要
In order to broaden the wavelength range of flat-field holographic concave grating (FHCG), the optimization method of parallel flat-field holographic concave gratings (PFHCGs) is proposed. Two flat-field gratings working in different wavebands, one for 2~5 nm and the other for 5~30 nm, are designed on the same substrate based on genetic algorithm, and the two gratings can work simultaneously because of the same working structure. Theoretical spectral resolution of PFHCGs is studied via ray-tracing method, which is pretty the same as that of existing commercial FHCG. Based on the optical path function theory, the recording optical path of PFHCGs is given. The results demonstrate the line density deviation is less than ±1 line/mm between theoretical value and optimization value. Simulation results show that the waveband of HPFCGs is broaden and the resolution is also ensured, so it is suitable for recording wider waveband of soft X-ray.
引用
收藏
相关论文
共 50 条
  • [21] Design method of convex master gratings for replicating flat-field concave gratings
    Zhou, Qian
    Li, Li-Feng
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2009, 29 (08): : 2281 - 2285
  • [22] Design Method of Convex Master Gratings for Replicating Flat-Field Concave Gratings
    Zhou Qian
    Li Li-feng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (08) : 2281 - 2285
  • [23] Optimum design of a holographic parallel flat-field grating
    Wang Qing-bo
    Liu Zheng-kun
    Chen Huo-yao
    Fu Shao-jun
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: IMAGING SPECTROMETER TECHNOLOGIES AND APPLICATIONS, 2013, 8910
  • [24] Calibration for 5 FW X-ray film using flat-field spectrometer
    Li, Ruxin
    Lu, Peixiang
    Fan, Pinzhong
    Xu, Zhizhan
    Wang, Xiaofang
    Li, Yaolin
    Lu, Haihe
    Zhang, Zhengquan
    Guangxue Xuebao/Acta Optica Sinica, 1994, 14 (01): : 68 - 72
  • [25] Limitations to flat-field correction methods when using an X-ray spectrum
    Davidson, DW
    Fröjdh, C
    O'Shea, V
    Nilsson, HE
    Rahman, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 146 - 150
  • [26] The concept of a stigmatic flat-field X-ray spectrograph based on conical diffraction
    Kolesnikov, A. O.
    Ragozin, E. N.
    Shatokhin, A. N.
    QUANTUM ELECTRONICS, 2022, 52 (05) : 491 - 496
  • [27] Performance of a flat-field grating spectrometer for tender x-ray emission spectroscopy
    Imazono, Takashi
    Ukita, Ryuichi
    Nishihara, Hiroaki
    Sasai, Hiroyuki
    Nagano, Tetsuya
    APPLIED OPTICS, 2018, 57 (27) : 7770 - 7777
  • [28] Development of soft X-ray multilayer laminar-type plane gratings and varied-line-spacing spherical grating for flat-field spectrograph in the 1-8 keV region
    Koike, Masato
    Ishino, Masahiko
    Imazono, Takashi
    Sano, Kazuo
    Sasai, Hiroyuki
    Hatayama, Masatoshi
    Takenaka, Hisataka
    Heimann, Philip A.
    Gullikson, Eric M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (08) : 756 - 760
  • [29] Comparison of mechanically ruled versus holographically varied line-spacing gratings for a soft-x-ray flat-field spectrograph
    Yamazaki, T
    Gullikson, E
    Miyata, N
    Koike, M
    Harada, Y
    Mrowka, S
    Kleineberg, U
    Underwood, JH
    Yanagihara, MM
    Sano, K
    APPLIED OPTICS, 1999, 38 (19) : 4001 - 4003
  • [30] Design of soft x-ray high diffraction efficiency and spectral flux Au/Ni bilayer coated laminar-type diffraction grating for objective soft x-ray flat-field spectrograph in a region of 250-550 eV
    Koike, M.
    Hatano, T.
    Pirozhkov, A. S.
    Murano, T.
    Oue, Y.
    Koshiya, S.
    Kakio, T.
    Kondo, K.
    Terauchi, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (12):