Suppression of interferences for direct determination of arsenic in geological samples by inductively coupled plasma mass spectrometry

被引:0
|
作者
机构
[1] [1,Hu, Zhaochu
[2] 1,Gao, Shan
[3] Hu, Shenghong
[4] Yuan, Honglin
[5] Liu, Xiaoming
[6] Liu, Yongsheng
来源
Hu, Z. (zchu@vip.sina.com) | 1600年 / Royal Society of Chemistry卷 / 20期
关键词
Arsenic - Hydrides - Inductively coupled plasma - Interference suppression - Ionization - Ions - Rare earth elements - Reduction;
D O I
暂无
中图分类号
学科分类号
摘要
We have developed a method for direct determination of arsenic in geological samples using ICP-MS by reduction of interferences, without preconcentration, separation and use of the hydride generation technique. Concentrations of HNO3 have a significant effect on the arsenic signal. This type of interference cannot be corrected by internal standards (Rh and In) because the signal suppression due to HNO3 is apparently dependent on the first ionization potential of elements. Addition of 4% (v/v) ethanol to 1-10% (v/v) HNO3 was found to be an excellent method for reducing this type of matrix effect from 30-40% to less than 5% for high first ionization potential elements 75As (9.81 eV), 82Se (9.75 eV), and 126Te (9.01 eV). Direct determination of arsenic in geological samples by ICP-MS is often complicated by the presence of Nd 2+, Sm2- and Eu2+ interferences, in addition to the well known interference of ArCl+, and the high first ionization potential of As (9.81 eV) also results in relatively low analytical sensitivity in ICP-MS. It is shown that both problems can be overcome by a combination of a 4% ethanol matrix modifier with nebulizer gas flow rate adjustment. For example, the interference from doubly charged ions of a rare earth element (Ce2+) is reduced by a factor of 30 with the addition of 4% ethanol at a nebulizer gas flow rate of 1.00 1 min- and rf power of 1350 W. while the signal intensity of As is similar in both solutions. A nebulizer gas flow rate of 0.94 1 min-1, an rf power of 1350 W and 4% ethanol modifier were chosen in practical sample analysis. Under these conditions, the interference of doubly charged ions of the rare earth element (Ce2+) was reduced by a factor of 6.5 and the signal intensity of As was improved by a factor of 3 relative to that in 3% (v/v) HNO3 solution at the corresponding optimum nebulizer gas flow rate of 0.98 l min -1 and rf power of 1350 W. The arsenic equivalent concentration caused by ArCl+ interference was reduced by a factor of 10 under our given experimental conditions in the presence of 4% (v/v) ethanol. The developed method was applied to the direct determination of arsenic in a series of international geological reference materials. Most of the results were found to be in reasonable agreement with the reported values in the literature, particularly for those having recommended values. This simple method shows a great potential for the direct determination of arsenic in geological and environmental samples. © The Royal Society of Chemistry 2005.
引用
收藏
相关论文
共 50 条
  • [11] Elimination of interferences in the determination of arsenic and determination of arsenic in percolate waters from an industrial landfill by inductively coupled plasma mass spectrometry
    Van den Broeck, K
    Vandecasteele, C
    ANALYTICAL LETTERS, 1998, 31 (11) : 1891 - 1903
  • [12] Direct determination of total arsenic and arsenic species by ion chromatography coupled with inductively coupled plasma mass spectrometry
    Nam, SH
    Kim, JJ
    Han, SS
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (12) : 1805 - 1808
  • [13] Systems for the suppression of spectral interferences for inductively coupled plasma mass-spectrometry
    A. Yu. Leykin
    P. V. Yakimovich
    Journal of Analytical Chemistry, 2012, 67 : 677 - 686
  • [14] Systems for the suppression of spectral interferences for inductively coupled plasma mass-spectrometry
    Leykin, A. Yu.
    Yakimovich, P. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 67 (08) : 677 - 686
  • [15] Spectral Interferences of Some Polyatomic Ions in the Determination of Traces of Platinum Metals and Gold in Geological Samples by Inductively Coupled Plasma Mass Spectrometry
    Tyutyunnik, O. A.
    Nabiullina, S. N.
    Kubrakova, I. V.
    Anosova, M. O.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (14) : 2051 - 2058
  • [16] Determination of trace cadmium in geological samples by membrane desolvation inductively coupled plasma mass spectrometry
    He, Dong
    Zhu, Zhenli
    Miao, Xin
    Zheng, Hongtao
    Li, Xiuli
    Belshaw, Nicholas S.
    Hu, Shenghong
    MICROCHEMICAL JOURNAL, 2019, 148 : 561 - 567
  • [17] Determination of trace elements in geological samples by laser ablation inductively coupled plasma mass spectrometry
    Becker, JS
    Dietze, HJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05): : 429 - 434
  • [18] Determination of trace elements in geological samples by laser ablation inductively coupled plasma mass spectrometry
    J. S. Becker
    H.-J. Dietze
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 429 - 434
  • [19] DETERMINATION OF ARSENIC IN SAMPLES WITH HIGH CHLORIDE CONTENT BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    BRANCH, S
    EBDON, L
    FORD, M
    FOULKES, M
    ONEILL, P
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) : 151 - 154
  • [20] Determination of arsenic in biological samples by inductively coupled plasma mass spectrometry with selenium as an internal standard
    Park, CJ
    Song, HJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (05) : 436 - 440