Evaluation of the force sensing application pressure mapping system

被引:6
|
作者
机构
[1] Dey, Zita Ranajoy
[2] Nair, Nadia R.
[3] Shapcott, Nigel
来源
Dey, Z.R. (zita.dey@wales.nhs.uk) | 1600年 / Informa Healthcare卷 / 37期
关键词
Accuracy - Calibration method - Calibration process - Calibration techniques - Calibration tests - Optimal calibration - Pressure mapping - Sensitive application;
D O I
10.3109/03091902.2013.765517
中图分类号
学科分类号
摘要
Pressure mapping techniques are used in wheelchair and seating services to assess posture and assist in the prevention and treatment of pressure ulcers. The Force Sensitive Application (FSA) pressure mapping systems in Wales have a high clinical use and frequent calibration is required. This project aimed to assess the performance of the systems and develop a calibration strategy. Testing of the systems was spilt into three stages. The pilot stage compared different calibration techniques (manual, automated and with new software) to determine the optimal calibration frequency. The second stage, longer term, was like the pilot stage with the best calibration method tested over 10 weeks. The third test was a simple before-and-after calibration test, conducted to determine the effect of calibration. It was concluded that the calibration process is essential to maintain the reliability of the mats and it was decided that the systems in Wales should be calibrated every 2 months to provide a more consistent output. © 2013 Informa UK Ltd.
引用
收藏
相关论文
共 50 条
  • [21] Evaluation of a force plate system for measuring center of pressure in railroad ballast
    Xu, Hang
    Merryweather, Andrew
    Bloswick, Donald
    GAIT & POSTURE, 2016, 46 : 179 - 183
  • [22] Evaluation of a master slave system with force sensing using pneumatic servo system for laparoscopic surgery
    Tadano, Kotaro
    Kawashima, Kenji
    Kagawa, Toshiharu
    PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-8, 2007, : 2862 - 2865
  • [23] Investigating gripping force during lifting tasks using a pressure sensing glove system
    Zhou, Guoyang
    Lu, Ming-Lun
    Yu, Denny
    APPLIED ERGONOMICS, 2023, 107
  • [24] Flexible Force-sensing System for Wearable Exoskeleton Using Liquid Pressure Detection
    Zhu, Yanhe
    Zhang, Guoan
    Xu, Weiming
    Zhao, Jie
    SENSORS AND MATERIALS, 2018, 30 (08) : 1655 - 1664
  • [25] Comparison between the force application point determined by portable force plate system and the center of pressure determined by pressure insole system during alpine skiing
    Nakazato K.
    Scheiber P.
    Müller E.
    Sports Engineering, 2013, 16 (04) : 297 - 307
  • [26] Evaluation of Force Feedback for Palpation and Application of Active Constraints on a Teleoperated System
    Psomopoulou, Efi
    Persad, Raj
    Koupparis, Anthony
    Abeywardena, Sajeeva
    Sani, Mohammad Fattahi
    Melhuish, Chris
    Dogramadzi, Sanja
    XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019, 2020, 76 : 1571 - 1580
  • [27] Development of a micromanipulation system with force sensing
    Khan, Shahzad
    Nergiz, Ahmet Ozcan
    Sabanovic, Asif
    Patoglu, Volkan
    2007 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-9, 2007, : 291 - 296
  • [28] Application of Sensing Techniques to Cellular Force Measurement
    Li, Bin
    Wang, James H. -C.
    SENSORS, 2010, 10 (11) : 9948 - 9962
  • [29] Remote sensing mapping of soil and plants as basis for a variable rate nutrient application system
    Bennedsen, BS
    Christensen, LK
    Pedersen, A
    Jensen, LS
    Nielsen, NE
    MONITORING FOOD SAFETY, AGRICULTURE, AND PLANT HEALTH, 2004, 5271 : 212 - 217
  • [30] A portable electrical impedance tomography based pressure mapping sensor and force localisation validation system
    Ellingham, Richie
    Holder-Pearson, Lui
    Pretty, Chris
    Giffney, Tim
    HARDWAREX, 2025, 21