Cost-effective post-tensioned bridge pier with internal dissipation

被引:0
|
作者
Piras S. [1 ]
Palermo A. [1 ]
机构
[1] Department of Civil and Natural Resources Engineering, University of Canterbury, Christchurch
来源
Resilient Cities and Structures | 2022年 / 1卷 / 01期
关键词
Bridge engineering; Dissipation solution; Dissipative controlled rocking column; Low-damage; Replaceable hinge; Resilience-based seismic design;
D O I
10.1016/j.rcns.2022.03.003
中图分类号
学科分类号
摘要
This paper presents the development and testing of a novel internal dissipation connection for the use of post-tensioned rocking columns. The solution is one of the many referring to the dissipative controlled rocking (DCR) bridge design philosophy. The internal dissipaters are carefully designed to be cost-effective and reduce the overall construction cost. The dissipaters are fully threaded, Grade 300 bars connected to the permanent column and foundation longitudinal reinforcement with threaded couplers. In this research, a DCR column is subjected to subsequent earthquake events, and the dissipaters' strain design limits are chosen such that there is no need for replacing after a significant seismic event. The result is a recommended design strain limit of 1.5% for the dissipaters that guarantees the structural integrity of the DCR column after a seismic event. Additionally, a cumulated strain of 5% is recommended for the dissipaters before replacement is suggested. The proposed connection detailing with replaceable internal dissipaters, combined with post-tensioned high strength bars and well-confined concrete, provided self-centring capabilities (no residual displacement), dissipation capacity and significantly less damage in the bridge column than a traditional reinforced concrete solution. © 2022
引用
收藏
页码:33 / 43
页数:10
相关论文
共 50 条
  • [31] RAILWAY BRIDGE USING SMALL POST-TENSIONED CONCRETE BOX GIRDER
    Rhee, Inkyu
    BALTIC JOURNAL OF ROAD AND BRIDGE ENGINEERING, 2012, 7 (02): : 137 - 144
  • [32] Reliability analysis of a post-tensioned bridge using NLFEA and random fields
    Diaz, R. Sanabria
    Nova, S. Sarmiento
    Trautwein, L. Mouta
    de Almeida, L. C.
    Texeira da Silva, M. C. A.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, LIFE-CYCLE SUSTAINABILITY AND INNOVATIONS, 2021, : 3747 - 3754
  • [33] Improving seismic performance of segmental precast post-tensioned bridge piers
    Amini, Mehrshad
    Mirtaheri, Masoud
    Zandi, Amir Peyman
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2017, 170 (12) : 928 - 938
  • [34] Influence of Cracking on Effects of Restrained Deformations in a Post-tensioned Concrete Bridge
    Jalonen, Kimmo
    Tulonen, Joonas
    Laaksonen, Anssi
    NORDIC CONCRETE RESEARCH, 2018, 59 (02): : 95 - 110
  • [35] 9 m glass bridge with post-tensioned reinforcement at glasstec 2014
    Weller, Bernhard
    Engelmann, Michael
    Stahlbau, 2015, 84 (S1) : 455 - 464
  • [36] Durability study of a 35-year-old post-tensioned bridge
    Schupack, Morris
    Concrete International, 1994, 16 (02) : 54 - 58
  • [37] POST-TENSIONING THE CONNECTION REGION OF PRECAST POST-TENSIONED BRIDGE GIRDERS FOR CONTINUITY
    Taha, Mutaz M. M.
    Jia, Yanmin
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2018, 27 (01):
  • [38] Nondestructive evaluation of grout defects in internal tendons of post-tensioned girders
    Terzioglu, Tevfik
    Karthik, Madhu M.
    Hurlebaus, Stefan
    Hueste, Mary Beth D.
    Maack, Stefan
    Woestmann, Jens
    Wiggenhauser, Herbert
    Krause, Martin
    Miller, Patrick K.
    Olson, Larry D.
    NDT & E INTERNATIONAL, 2018, 99 : 23 - 35
  • [39] Adjacent box girders without internal diaphragms or post-tensioned joints
    Hanna, Kromel
    Morcous, George
    Tadros, Maher K.
    PCI JOURNAL, 2011, : 51 - 64
  • [40] Simulation of post-tensioned bridge columns under reversed-cyclic loads
    Laskar, Arghadeep
    Mo, Y. L.
    Hsu, Thomas T. C.
    MATERIALS AND STRUCTURES, 2016, 49 (06) : 2237 - 2256