Micro-CT scanners for biomedical applications: An overview

被引:0
|
作者
Wang, G. [1 ]
Vannier, M. [1 ]
机构
[1] Department of Radiology, Department of Biomedical Engineering, University of Iowa, Iowa City, IA, United States
关键词
Biomedical engineering - Charge coupled devices - Computer aided diagnosis - Image analysis - Medical imaging - Scanning;
D O I
暂无
中图分类号
学科分类号
摘要
The functioning and construction of micro-computerized tomography (CT) scanners, used in biomedical imaging, is discussed. The features of a typical micro-CT scanner include an X-ray microfocused source; a detector array; an object stage; a system control mechanism; and computing resources for image reconstruction. Micro-CT scanners can be used for bone analysis, to identify phenotypes of small animals, in assessing and monitoring tumours in small animals, and in studies of vascular structures.
引用
收藏
页码:18 / 27
相关论文
共 50 条
  • [21] Micro-CT in drug delivery
    Wang, Yiwei
    Wertheim, David F.
    Jones, Allan S.
    Coombes, Allan G. A.
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2010, 74 (01) : 41 - 49
  • [22] Spectral optimization for micro-CT
    Hupfer, Martin
    Nowak, Tristan
    Brauweiler, Robert
    Eisa, Fabian
    Kalender, Willi A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3229 - 3239
  • [23] Micro-CT performance testing
    Eloot, L.
    Buls, N.
    Willekens, I.
    Lahoutte, T.
    de Mey, J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 154 - 157
  • [24] State of art micro-CT
    Sassov, A
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 515 - 520
  • [25] Standardization of mineral density maps of physiologic and pathologic biominerals in humans using cone-beam CT and micro-CT scanners
    Srirangapatanam, Sudarshan
    Kang, Misun
    Ellenikiotis, Yianni
    Jheon, Andrew
    Kapila, Sunil
    Swana, Hubert S.
    Stoller, Marshall L.
    Seo, Youngho
    Ho, Sunita P.
    DENTAL MATERIALS, 2022, 38 (06) : 989 - 1003
  • [26] Laser scanners: From industrial to biomedical applications
    Duma, Virgil-Florin
    8TH IBEROAMERICAN OPTICS MEETING AND 11TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND APPLICATIONS, 2013, 8785
  • [27] Micro-CT as a guide for clinical CT development
    Ritman, Erik L.
    Eaker, Diane R.
    Jorgensen, Steven M.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [28] Effect of experimental parameters on X-ray Micro-CT imaging for Spectral CT applications
    Lima, Mateus Gruener
    Jussiani, Eduardo Inocente
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [29] Implementation of interior micro-CT on a carbon nanotube dynamic micro-CT scanner for lower radiation dose
    Gong, Hao
    Lu, Jianping
    Zhou, Otto
    Cao, Guohua
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [30] E15.5 Mouse Embryo Micro-CT Using a Bruker Skyscan 1172 Micro-CT
    Astanina, Elena
    Petrillo, Sara
    Genova, Tullio
    Mussano, Federico
    Bussolino, Federico
    BIO-PROTOCOL, 2023, 13 (09):