A Decoupling Control Method for Shunt Hybrid Active Power Filter Based on Generalized Inverse System

被引:82
|
作者
Li X. [1 ,2 ]
Li B. [2 ]
机构
[1] Key Laboratory of Optoelectronic Technology and Intelligent Control, Ministry of Education, Lanzhou Jiaotong University, Lanzhou
[2] School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou
来源
Li, Xin (lxfp167@163.com) | 1600年 / Hindawi Limited, 410 Park Avenue, 15th Floor, 287 pmb, New York, NY 10022, United States卷 / 2017期
基金
中国国家自然科学基金;
关键词
MATLAB;
D O I
10.1155/2017/5232507
中图分类号
学科分类号
摘要
In this paper, a novel decoupling control method based on generalized inverse system is presented to solve the problem of SHAPF (Shunt Hybrid Active Power Filter) possessing the characteristics of 2-input-2-output nonlinearity and strong coupling. Based on the analysis of operation principle, the mathematical model of SHAPF is firstly built, which is verified to be invertible using interactor algorithm; then the generalized inverse system of SHAPF is obtained to connect in series with the original system so that the composite system is decoupled under the generalized inverse system theory. The PI additional controller is finally designed to control the decoupled 1-order pseudolinear system to make it possible to adjust the performance of the subsystem. The simulation results demonstrated by MATLAB show that the presented generalized inverse system strategy can realise the dynamic decoupling of SHAPF. And the control system has fine dynamic and static performance. © 2017 Xin Li and Bo Li.
引用
收藏
相关论文
共 50 条
  • [21] A decoupling discrete-time control methodology applied to shunt active power filter
    Wang, Hui
    Duan, Yu-Bing
    Gong, Yu-Lei
    Li, Qing-Min
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (11): : 48 - 54
  • [22] Stability of hybrid shunt active power filter
    Tang, Ci
    Luo, An
    Zhao, Wei
    Shuai, Zhi-Kang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (06): : 42 - 48
  • [23] The Research on Hybrid Shunt Active Power Filter
    Zhong Tingjian
    Fan Youping
    Xie Youhui
    2009 INTERNATIONAL SYMPOSIUM ON WEB INFORMATION SYSTEMS AND APPLICATIONS, PROCEEDINGS, 2009, : 100 - 103
  • [24] Research on shunt active power filter based on a control method of PI conversation of energy
    Lu, Hao
    Song, Ming-Hua
    Xie, Qi
    Liang, Sheng-Jun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (12): : 68 - 72
  • [25] Sliding Mode Control Based Shunt Active Power Filter
    Skuriatin, Y., V
    Belousov, A., V
    Denysevych, N. A.
    PROBLEMELE ENERGETICII REGIONALE, 2018, (02): : 20 - 30
  • [26] Artificial Intelligence Based Control of a Shunt Active Power Filter
    Choudhary, Jayanti
    Singh, D. K.
    Verma, S. N.
    Ahmad, Kamil
    2ND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING, COMMUNICATION & CONVERGENCE, ICCC 2016, 2016, 92 : 273 - 281
  • [27] Disturbance Observer Based Control of Shunt Active Power Filter
    Kurak, Sevkuthan
    NEW TECHNOLOGIES, DEVELOPMENT AND APPLICATION IV, 2021, 233 : 549 - 562
  • [28] Passivity-based control of a three-phase shunt hybrid active power filter
    Lu, W., 1600, Editorial Department of Electric Machines and Control (18):
  • [29] Hybrid Control of Single Phase Shunt Active Power Filter Based on Interleaved Buck Converter
    Echalih, S.
    Abouloifa, A.
    Lachkar, I
    Hekss, Z.
    Aourir, M.
    Giri, F.
    2019 AMERICAN CONTROL CONFERENCE (ACC), 2019, : 3636 - 3641
  • [30] Control System Design of Shunt Active Power Filter Based on Active Disturbance Rejection and Repetitive Control Techniques
    Ge, Le
    Yuan, Xiaodong
    Yang, Zhong
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2014, 2014