Study on the influence of fire source location on cable tunnel detection and alarm system

被引:0
|
作者
Lei, Lei [1 ,2 ]
Wang, Zeyu [1 ]
Liang, Zihao [3 ]
机构
[1] China Peoples Police Univ, Sch Fire Protect Engn, Langfang 065000, Hebei, Peoples R China
[2] Univ Sci & Technol China, Hefei 230000, Anhui, Peoples R China
[3] Qingdao Univ, Rizhao 276825, Shangdong, Peoples R China
关键词
Cable tunnel; Fire source location; Intelligent active suction detection method; Response time;
D O I
10.1016/j.csite.2024.105507
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to study the fire detection method of cable tunnel. We carried out physical experiments in the cable tunnel test section, using the heater pyrolyze PVC so that its pyrolysis as the ignition source obtained a total of 17 fire source location points in the horizontal and vertical directions of seven different fire detectors, and only processed the response time data of the alarm detector obtained the response time and the analysis results were drawn. With the increase of the distance from the fire source, the response time of each type of detector increases in different forms. It is found that the detection distance of the grating fiber temperature sensor is shorter, and the response time near the fire source is more stable. The detection performance of the point pyrolytic particle detector is more affected by the detection distance, which is advantageous for the detection point to have better response performance. The intelligent active suction detector is also affected by the detection distance, which is less affected than the point detector, the response time curve is more stable, and the detection performance is better at each test point. Clc number: X Document Identification Code; A.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Study on the influence of the longitudinal position of fire source and tunnel width on the maximum ceiling gas temperature
    He, Lu
    Liao, Ke
    Zhu, Guoqing
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 52
  • [22] Experimental study on fire performance of optical cables used in utility tunnel: Influence of cable spacing and heat flux
    An, Weiguang
    Sun, Xiaoxiao
    Tang, Yanhua
    Wang, Tao
    Wang, Zhe
    FIRE AND MATERIALS, 2023, 47 (07) : 884 - 891
  • [23] Design of Wireless Fire Detection and Alarm System Based on ZigBee Technology
    Chen, Bo
    Hu, Ze
    Ge, Liang
    Li, Junlan
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 3662 - 3665
  • [24] Studies on system of fire detection and alarm based on ultrasonic and temperature sensor
    Wang, HP
    Kang, JL
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A and B, 2004, 4 : 1283 - 1286
  • [25] Information fusion technology based on wireless fire detection and alarm system
    Niu Linghui
    Hu Zhuge
    ADVANCES IN MECHATRONICS, AUTOMATION AND APPLIED INFORMATION TECHNOLOGIES, PTS 1 AND 2, 2014, 846-847 : 883 - +
  • [26] Experimental investigation on the influence of longitudinal fire location on critical velocity in a T-shaped tunnel fire
    Chen, Changkun
    Jiao, Weibing
    Zhang, Yulun
    Shi, Congling
    Lei, Peng
    Fan, Chuangang
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 134
  • [27] Study of the Transducer Fault Diagnosis Module for Fire Alarm System
    Liu Minlin
    Liu Boyun
    PROGRESS IN MECHATRONICS AND INFORMATION TECHNOLOGY, PTS 1 AND 2, 2014, 462-463 : 45 - 50
  • [28] Experimental study on fire characteristics in cable compartment of utility tunnel with natural ventilation
    Bai, Z. P.
    Yao, H. W.
    Zhang, H. H.
    PLOS ONE, 2022, 17 (04):
  • [29] Two dimensional source location system for rock fall detection by using cable sensor and mobile multimedia network
    Ujihira, M.
    Ogawa, K.
    Suzuki, S.
    Hosoya, S.
    Saeki, H.
    Komazaki, M.
    International Journal of Rock Mechanics and Mining Sciences, 1997, 34 (3-4): : 1 - 315
  • [30] A computational study on effects of fire location on smoke movement in a road tunnel
    Wang, Feng
    Wang, Mingnian
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2016, 51 : 405 - 413