Experimental investigation of thermal performance of ground source heat pump system for summer and monsoon seasons of Himalayan region of India: A case study

被引:2
|
作者
Kumar, Satish [1 ]
Murugesan, Krishnan [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Roorkee 247667, India
基金
英国工程与自然科学研究理事会;
关键词
Ground source heat pump system; Borehole heat exchanger; Air-conditioning; Psychrometric process; Coefficient of performance; COOLING PERFORMANCE; U-TUBE; ENERGY; SIMULATION; EFFICIENCY; EXCHANGER;
D O I
10.1016/j.renene.2024.121842
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present experimental research work examines the thermal interactions of borehole heat exchangers on the ground side and psychrometric process involved inside the room during cooling mode operation using a ground source heat pump system (GSHP). An experimental facility of 17.5 kW cooling capacity GSHP system, consisting of five parallelly connected double U-tube borehole heat exchangers fitter with a commercially available heat pump system has been employed. The experiments were performed during peak summer and monsoon (rainy) seasons for space cooling applications for 45 hours of continuous operation in a city located in the Himalayan range of India. Analysis of results obtained indicate that during the summer season the hourly heat rejected to the ground is maximum for peak weather conditions due to high cooling load demand on the user side. On increasing the building load (increase in ambient temperature), there is a slight decrease in COPsys in both the seasons. During heavy rain season, the latent cooling load increases up to 1.5 times of the sensible cooling load. The average value of sensible heat factor is found to be 0.6 for the case of the peak summer season and 0.51 for the rainy season.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Performance analysis and optimization of photovoltaic thermal coupled ground source heat pump system
    Wei, Wenqi
    Yue, Han
    Huang, Jiguang
    Zhang, Heng
    Liu, Haowen
    Chen, Haiping
    Cheng, Chao
    ENERGY, 2025, 319
  • [42] The influence of soil thermal properties on the operation performance on ground source heat pump system
    Li, Biao
    Han, Zongwei
    Bai, Chenguang
    Hu, Honghao
    RENEWABLE ENERGY, 2019, 141 : 903 - 913
  • [43] Performance enhancement of a photovoltaic thermal (PVT) and ground-source heat pump system
    Abu-Rumman, Mohammad
    Hamdan, Mohammad
    Ayadi, Osama
    GEOTHERMICS, 2020, 85
  • [44] Experimental thermal performance of a solar source heat-pump system for residential heating in cold climate region
    Bakirci, Kadir
    Yuksel, Bedri
    APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) : 1508 - 1518
  • [45] Improved method and case study of thermal response test for borehole heat exchangers of ground source heat pump system
    Wang, Huajun
    Qi, Chengying
    Du, Hongpu
    Gu, Jihao
    RENEWABLE ENERGY, 2010, 35 (03) : 727 - 733
  • [46] Hybrid Solar Thermal and Ground Source Heat Pump System
    Rad, Farzin M.
    Fung, Alan S.
    Leong, Wey H.
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 253 - 260
  • [47] ENHANCED GROUND SOURCE HEAT PUMP SYSTEM WITH THERMAL STORAGE SYSTEM
    Taira, Hirotoshi
    Sato, Takashi
    Kakizaki, Takao
    Oguma, Masahito
    PROCEEDINGS OF THE ASME 12TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2018, 2018,
  • [48] Enhanced Ground Source Heat Pump System With Thermal Storage System
    Taira, Hirotoshi
    Sato, Takashi
    Kakizaki, Takao
    Oguma, Masahito
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2019, 141 (06):
  • [49] Experimental and computational investigation of the spiral ground heat exchangers for ground source heat pump applications
    Dehghan, Babak B.
    APPLIED THERMAL ENGINEERING, 2017, 121 : 908 - 921
  • [50] Case study of performance evaluation of ground source heat pump system based on ANN and ANFIS models
    Sun, Weijuan
    Hu, Pingfang
    Lei, Fei
    Zhu, Na
    Jiang, Zhangning
    APPLIED THERMAL ENGINEERING, 2015, 87 : 586 - 594