Experimental study for laminated glass composed of tempered fire resistance glass exposed to standard heating

被引:0
|
作者
Suzuki K. [1 ,2 ]
Hisada T. [1 ,2 ]
Sato A. [3 ]
Ohmiya Y. [4 ]
机构
[1] Nippon Sheet Glass Co, Ltd.
[2] Nippon Sheet Glass Co., Ltd.
[3] Asahi Glass Co., Ltd.
[4] Faculty of Science and Technology, Tokyo University of Science
来源
关键词
Emissivity of Low-E glass; Interlayer; Laminated glass; Surface Compression Stress; Tempered fire resistance glass;
D O I
10.3130/aije.83.415
中图分类号
学科分类号
摘要
For the performance of laminated glass composed of tempered fire resistance glass, the temperature data of the glass were obtained by fire tests, and checked the breakage factor of the glass. Findings are as follows. 1. In the heated laminated glass, the intermediate film exhibits complicated behavior. 2. Tempered fire resistance glass used as laminated glass has a strong correlation between surface compression stress induced in a glass pane and temperature difference between glass surface temperature and glass edge temperature. 3. Temperature difference of laminated glass can be explained in consideration of the thermal influence of the interlayer. 4. Low -E type laminated IGU can be evaluated by considering it as the same as LowE IGU, regarding tempered fire resistance glass. © 2018 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:415 / 424
页数:9
相关论文
共 50 条
  • [21] Seismic Behaviour of Composite Panel Composed of Laminated Wood and Bearing Glass - Experimental Investigation
    Krstevska, Lidija
    Tashkov, Ljubomir
    Rajcic, Vlatka
    Zarnic, Roko
    STRUCTURAL HEALTH ASSESSMENT OF TIMBER STRUCTURES, 2013, 778 : 698 - 705
  • [22] Experimental study on fire resistance of prestressed laminated slabs
    Zhao K.
    Wei F.
    Gao W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (05): : 140 - 148
  • [23] Recent experimental results about the behaviour of laminated glass exposed to snowfall events
    Naessl, Andreas
    Bues, Martin
    Mensinger, Martin
    Bucak, Oemer
    STAHLBAU, 2012, 81 (03) : 197 - 202
  • [24] Experimental investigation into the fragment size of tempered glass
    Pourmoghaddam, N.
    Schneider, J.
    GLASS STRUCTURES & ENGINEERING, 2018, 3 (02) : 167 - 181
  • [25] Experimental investigation on the blast resistance of framed PVB-laminated glass
    Chen, Xing
    Chen, Suwen
    Li, Guo-Qiang
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2021, 149
  • [26] Testing Laminated Glass for Impact Resistance
    A. I. Shutov
    A. N. Frank
    I. A. Novikov
    A. S. Ostapko
    A. S. Bonchuk
    A. N. Burdov
    Glass and Ceramics, 2004, 61 : 67 - 69
  • [27] Testing of laminated glass for impact resistance
    Shutov, A.I.
    Frank, A.N.
    Novikov, I.A.
    Ostapko, A.S.
    Bonchuk, A.S.
    Burdov, A.N.
    Steklo i Keramika, 2004, (03): : 3 - 5
  • [28] Testing laminated glass for impact resistance
    Shutov, AI
    Frank, AN
    Novikov, IA
    Ostapko, AS
    Bonchuk, AS
    Burdov, AN
    GLASS AND CERAMICS, 2004, 61 (3-4) : 67 - 69
  • [29] Experimental study on fire performance of cross laminated timber structure exposed to compartment fire
    Zhang J.
    Sun Y.
    Wang Y.
    Lu C.
    Wang W.
    Wu L.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (09): : 115 - 127
  • [30] Determination of critical fallout condition of tempered glass in an enclosure fire
    Wang, Yu
    Rush, David
    FIRE SAFETY JOURNAL, 2018, 101 : 18 - 24