Performance of Gas-Steam Combined Cycle Cogeneration Units Influenced by Heating Network Terminal Steam Parameters

被引:0
|
作者
Xie G. [1 ]
Xue Z. [1 ]
Xiong B. [1 ]
Huang Y. [1 ]
Chen C. [1 ]
Liao Q. [1 ]
Yang C. [2 ]
Ma X. [2 ]
机构
[1] Zhongshan Jiaming Electric Power Co., Ltd, CNOOC Gas & Power Group, Zhongshan
[2] School of Electric Power, South China University of Technology, Guangzhou
关键词
cogeneration of heating and power; Gas-steam combined cycle; inverse problem; operating performance; steam network;
D O I
10.32604/ee.2024.047832
中图分类号
学科分类号
摘要
The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems. This paper investigated the coupling performance of a cogeneration heating and power system multidimensionally based on the operating characteristics of the cogeneration units, the hydraulic and thermodynamic characteristics of the heating network, and the energy loads. Taking a steam network supported by a gas-steam combined cycle cogeneration system as the research case, the interaction effect among the source-side prime movers, the heating networks, and the terminal demand thermal parameters were investigated based on the designed values, the plant testing data, and the validated simulation. The operating map softhe gas-steam combined cycle cogeneration units were obtained using THERMOFLEX, and the minimum source-side steam parameters of the steam network were solved using an inverse solution procedure based on the hydro-thermodynamic coupling model. The cogeneration operating maps indicate that the available operating domain considerably narrows with the rise of the extraction steam pressure and flow rate. The heating network inverse solution demonstrates that the source-side steam pressure and temperature can be optimized from the originally designed 1.11 MPa and 238.8°C to 1.074 MPa and 191.15°C, respectively. Under the operating strategy with the minimum source-side heating parameters, the power peak regulation depth remarkably increases to 18.30% whereas the comprehensive thermal efficiency decreases. The operation under the minimum source-side heating steam parameters can be superior to the originally designed one in the economy at a higher price of the heating steam. At a fuel price of $0.38/kg and the power to fuel price of 0.18 kg/(kW·h), the critical price ratio of heating steam to fuel is 119.1 kg/t. The influence of the power-fuel price ratio on the economic deviation appears relatively weak. © 2024, Tech Science Press. All rights reserved.
引用
收藏
页码:1495 / 1519
页数:24
相关论文
共 50 条
  • [21] Dynamic simulation model for gas-steam combined cycle thermodynamic system
    Wang, Bing-Shu
    Cui, Ning
    Zhang, Cong-Shi
    Ma, Jin
    Deng, Yong
    2008, Acta Simulata Systematica Sinica, Beijing, 100854, China (20):
  • [22] Optimization calculation of characteristic parameters of gas-steam combined cycle system combusting crude gas and purge gas
    Dong, Chen
    Zhou, Qulan
    Xu, Tongmo
    Hui, Shi'en
    Huang, Jibing
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 99 - 102
  • [23] A Gas-Steam Combined Cycle Powered By Syngas Derived From Biomass
    Fortunato, Bernardo
    Camporeale, Sergio M.
    Torresi, Marco
    4TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT 2013), THE 3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2013), 2013, 19 : 736 - 745
  • [24] COMBINED GAS-STEAM CYCLE STATIONS HELP SOLVE ENVIRONMENTAL PROBLEMS
    不详
    ELECTRICAL REVIEW, 1972, 191 (08): : 262 - &
  • [25] EXPERIENCE WITH GAS-STEAM COMBINED CYCLE TURBINES ON A NATURAL-GAS PIPELINE
    WRENN, KF
    HEARD, TC
    LANG, RP
    MECHANICAL ENGINEERING, 1977, 99 (07) : 92 - 92
  • [26] The investment required to implement the urban cogeneration plants with gas-steam combined cycle and its influence over the main technical-economic parameters
    Hoarə, Marius-Costel
    Athanasovici, Victor
    UPB Scientific Bulletin, Series C: Electrical Engineering and Computer Science, 2015, 77 77 (2 2): : 263 - 276
  • [27] Safety System Analysis on Gas-steam Combined Cycle Power Plant
    Zhang, Jinfeng
    Li, Zaixing
    Liu, Xin
    Sun, Zhongqiang
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 1458 - 1463
  • [28] THE INVESTMENT REQUIRED TO IMPLEMENT THE URBAN COGENERATION PLANTS WITH GAS-STEAM COMBINED CYCLE AND ITS INFLUENCE OVER THE MAIN TECHNICAL-ECONOMIC PARAMETERS
    Hoara, Marius-Costel
    Athanasovici, Victor
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2015, 77 (02): : 263 - 276
  • [29] COMBINED GAS-STEAM TURBINE POWER-STATION FOR DISTRICT HEATING IN UTRECHT
    GUBSER, HR
    BROWN BOVERI REVIEW, 1978, 65 (10): : 687 - 690
  • [30] Combined heat and power dispatching model based on gas-steam combined cycle unit
    Yang K.
    Xu D.
    Xie H.
    Ding Q.
    Hu L.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (08): : 137 - 144