Protection method for high-impedance grounding fault in neutral isolated system based on comparative phase analysis of fault phase voltage and zero-sequence current

被引:0
|
作者
Wang, Pengwei [1 ]
Xu, Bingyin [1 ,2 ]
Wang, Chao [2 ]
Chen, Heng [1 ,2 ]
机构
[1] School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo,255000, China
[2] Shandong Kehui Electric Power Automation Co.,Ltd., Zibo,255000, China
关键词
Project supported by the Science and Technology Program of Headquaters of State Grid Corporation of China\uFF085500-202221138A\u20111\u20111\u2011ZN\uFF09;
D O I
10.16081/j.epae.202408015
中图分类号
学科分类号
摘要
24
引用
收藏
页码:148 / 156
相关论文
共 50 条
  • [31] A Simple High Impedance Fault Detection Method based on Phase Displacement and Zero Sequence Current for Grounded Distribution Systems
    Myint, Shwe
    Wichakool, Warit
    Santiprapan, Phonsit
    2018 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2018,
  • [32] Induction Motor Fault Diagnosis Based on Zero-Sequence Current Analysis
    Duda, Arkadiusz
    Drozdowski, Piotr
    ENERGIES, 2020, 13 (24)
  • [33] Protection scheme based on the fault transient component of zero-sequence voltage under the stator ground fault of generators
    Bi, Da-Qiang
    Wang, Xiang-Heng
    Gui, Lin
    Wang, Wei-Jian
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (11): : 39 - 44
  • [34] A Single-Phase-to-Ground Fault Detection Method Based on the Ratio Fluctuation Coefficient of the Zero-Sequence Current and Voltage Differential in a Distribution Network
    Liang, Huamin
    Li, Haifeng
    Wang, Gang
    IEEE ACCESS, 2023, 11 : 7297 - 7308
  • [35] Fault Line Selection Method for High-Impedance Grounding Fault of Resonant Grounded System Based on Change Rate of Virtual Energy
    Wang Z.
    Wu S.
    Luan X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (03): : 137 - 146
  • [36] Protection Principle of Single-Phase High Resistance Fault for Distribution Network Based on Zero-Sequence Power Variation
    Long Y.
    Ouyang J.
    Xiong X.
    Ma G.
    Yang M.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (17): : 3687 - 3695
  • [37] High Impedance Grounding Fault Protection for Low-resistance Grounding System Based on the Ratio of Phase Active Power Variation
    Guo, Liang
    Yu, Dongbin
    He, Hongru
    Lu, Weitian
    Liang, Huamin
    Li, Haifeng
    2023 6TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY AND POWER ENGINEERING, REPE 2023, 2023, : 76 - 81
  • [38] High Resistance Ground Fault Protection of Low Resistance Grounding System Based on Zero Sequence Current Projection Coefficient
    Yang F.
    Liu X.
    Shen Y.
    Xue Y.
    Zhou Z.
    Xu B.
    Dianwang Jishu/Power System Technology, 2020, 44 (03): : 1128 - 1133
  • [39] Zero-Sequence Current Suppression Method for Fault-Tolerant OW-PMSM Drive With Asymmetric Zero-Sequence Voltage Injection
    Zhang, Chong
    Gan, Chun
    Ni, Kai
    Yu, Zhiyue
    Chen, Yu
    Shi, Haochen
    Qu, Ronghai
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (03) : 2351 - 2362
  • [40] Ground-fault protection based on active component of zero-sequence current in resistance neutral grounded distribution systems
    Mu, LH
    Meng, QH
    2002 IEEE REGION 10 CONFERENCE ON COMPUTERS, COMMUNICATIONS, CONTROL AND POWER ENGINEERING, VOLS I-III, PROCEEDINGS, 2002, : 1897 - 1900