Influence of the test voltage function over lightning impulse response parameters measured by long cable

被引:0
|
作者
Sato S. [1 ]
Nishimura S. [2 ]
Shimizu H. [2 ]
Ikeda H. [3 ]
机构
[1] Graduate School of Engineering, Utsunomiya University, 7-1-2, Yoto, Utsunomiya, Tochigi
[2] UHV Laboratory, Nippon Institute of Technology, Gakuendai 4-1, Miyashiro-Machi, Saitama
[3] School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo
来源
IEEJ Transactions on Power and Energy | 2018年 / 138卷 / 03期
关键词
IEC; 60060-1; Lightning impulse response; Long measuring cable; Test voltage function;
D O I
10.1541/ieejpes.138.242
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The test voltage function or k-factor was newly introduced in IEC 60060-1:2010. With the k-factor combined with base curve technique, lightning impulse parameters have been evaluated much easily and stably than with the old method defined in IEC 60060-1:1989. Now there has been a report in IEC TC 42 committee that front time evaluated from recorded curve of a smooth waveform at the end of a long measuring cable becomes much larger by IEC 60060-1:2010 definition than with IEC 60060-1:1989 description. Authors could not only confirm this phenomenon and found reasons to cause but also propose a technique to circumvent this difficulty. In the paper, details of the counter measures and arrangement of the measuring system, which eliminates erroneous front time evaluation, are introduced. © 2018 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:242 / 248
页数:6
相关论文
共 50 条
  • [41] Overvoltage Produced by Lightning Impulse in High Power Transformers - Parameters that Influence their Transmission
    Nitu, Maria-Cristina
    Nicola, Marcel
    Nicola, Claudiu-Ionel
    Aciu, Ancuta-Mihaela
    Ocoleanu, Daniel
    Salceanu, Cristian Eugeniu
    2021 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE), 2021,
  • [42] Research on injection charge characteristics of long streamer under positive lightning impulse voltage
    Geng, Yinan
    AIP ADVANCES, 2020, 10 (02)
  • [43] Study on Influence Factors of Lightning Impulse Test Waveform of UHV GIS Equipment
    Meng, Jiadong
    Chen, Tianxiang
    Chen, Dajin
    Wang, Rongquan
    Wang, Lei
    2018 2ND INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING (ICPEE 2018), 2018, 192
  • [44] Proposal for the Lightning Impulse Voltage Parameters Evaluation Procedure in IEC 60060-1:2010
    Sato, Shuji
    Nishimura, Seisuke
    Shimizu, Hiroyuki
    Iked, Hisatoshi
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 650 - 662
  • [45] Oscillating Lightning Impulse Voltage Withstand Test and Partial Discharge Detection Technology for Power Transformers
    Zhang X.
    Wang H.
    Hu Y.
    Zhou Y.
    Li J.
    Han X.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (12): : 5032 - 5041
  • [46] Influence of meteorological parameters on lightning flashes over Indian region
    Pramod Kumar Yadava
    Ajay Sharma
    Swagata Payra
    R K Mall
    Sunita Verma
    Journal of Earth System Science, 132
  • [47] Influence of meteorological parameters on lightning flashes over Indian region
    Yadava, Pramod Kumar
    Sharma, Ajay
    Payra, Swagata
    Mall, R. K.
    Verma, Sunita
    JOURNAL OF EARTH SYSTEM SCIENCE, 2023, 132 (04)
  • [48] Influence accretions of front of time lightning impulse on withstand voltage of real lines and stations systems of high voltage
    Mackiewicz, Marcin Maciej
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 272 - 275
  • [49] Research on over-voltage induced by lightning on directly-buried communication coaxial cable
    Zhang, Shuiping
    He, Jingliang
    Wang, Hongxin
    Song, Zeqing
    Zhu, Wenbing
    Hu, Weibing
    Gaodianya Jishu/High Voltage Engineering, 2002, 28 (11):
  • [50] Discharge Process on Long Rod-Rod Electrodes Under Positive Lightning Impulse Voltage
    Guerlek, Akif
    Shirvani, Ali
    Hoshmeh, Abdullah
    Schufft, Wolfgang
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 843 - 854