Seismic performance and risk assessment of self-centering steel braced frames considering failure of prestressed tendons

被引:0
|
作者
Ping Y. [1 ]
Fang C. [1 ,2 ]
Chen Y. [1 ,2 ]
机构
[1] College of Civil Engineering, Tongji University, Shanghai
[2] State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University, Shanghai
关键词
Collapse-resisting; Fragility analysis; Residual deformation; Risk assessment; Self-centering brace; SMA; Tendon failure;
D O I
10.14006/j.jzjgxb.2020.0658
中图分类号
学科分类号
摘要
This paper comprehensively discussed the performance of self-centering steel braced frames suffering failure of prestressed tendons. The performance of the structures with shape memory alloy (SMA) cable-based self-centering braces was also examined. Through theoretical analysis, the fundamental mechanism of tendon failure of typical single core and dual core self-centering braces is first introduced, and it is found that the dual core self-centering brace may suffer more abrupt failure, although its deformability is improved. Four prototype structures were designed, i.e., an ideal self-centering braced frame without considering the failure of prestressed tendons, single core and dual core self-centering braced frames considering the failure of prestressed tendons, as well as an SMA-based self-centering braced frame. Considering a random distribution of tendon failure strain, nonlinear time history analysis was carried out on the frames under far-field and near-field earthquakes. Furthermore, the collapse and residual deformation fragilities of the frames were evaluated, and risk assessment was conducted according to the site characteristics. The results show that the risk of collapse is significantly increased when considering the failure of the prestressed tendons. During their service life, the collapse probability is about five times that of the ideal case and the probability of exceedance of residual deformation is up to six times that of the ideal case when tendon failure is considered. The SMA self-centering brace has enhanced deformation capacity and enables additional energy dissipation, and hence performs better in mitigating both the risk of collapse and residual deformation. © 2022, Editorial Office of Journal of Building Structures. All right reserved.
引用
收藏
页码:1 / 10and20
页数:1019
相关论文
共 29 条
  • [21] Minimum design loads and associated criteria for buildings and other structures, (2017)
  • [22] FANG C, ZHONG Q, WANG W, Et al., Peak and residual responses of steel moment-resisting and braced frames under pulse-like near-fault earthquakes, Engineering Structures, 177, pp. 579-597, (2018)
  • [23] EROCHKO J A., Improvements to the design and use of post-tensioned self-centering energy-dissipative (SCED) braces, (2013)
  • [24] BANIBAYAT P., Experimental investigation of the mechanical and creep rupture properties of basalt fiber reinforced polymer (BFRP) bars, pp. 29-31, (2011)
  • [25] VAMVATSIKOS D, CORNELL C A., Incremental dynamic analysis, Earthquake Engineering & Structural Dynamics, 31, 3, pp. 491-514, (2002)
  • [26] YE Lieping, MA Qianli, MIAO Zhiwei, Study on earthquake intensities for seismic analysis of structures, Journal of Earthquake Engineering and Engineering Vibration, 29, 4, pp. 9-22, (2009)
  • [27] Seismic performance assessment of buildings: bolume 1:methodology:FEMA P58-1, (2018)
  • [28] Quantification of building seismic performance factors:FEMA P695, (2009)
  • [29] EADS L, MIRANDA E, KRAWINKLER H, Et al., An efficient method for estimating the collapse risk of structures in seismic regions, Earthquake Engineering & Structural Dynamics, 42, 1, pp. 25-41, (2013)