One-step preparation of silver-polyaniline nanotube composite for non-enzymatic hydrogen peroxide detection

被引:0
|
作者
Lorestani, Farnaz [1 ]
Shahnavaz, Zohreh [1 ]
Nia, Pooria Moozarm [1 ]
Alias, Y. [1 ]
Manan, Ninie S.A. [1 ]
机构
[1] Department of Chemistry, University Malaya, Kuala Lumpur,50603, Malaysia
关键词
Silver compounds - Oxidation - Metal nanoparticles - Scanning electron microscopy - Nanocomposites - Nanotubes - Polyaniline - Yarn - Glass membrane electrodes - Signal to noise ratio - Silver nanoparticles - Ammonia - Size distribution;
D O I
暂无
中图分类号
学科分类号
摘要
A modified glassy carbon electrode with silver nanoparticles-polyaniline nanotubes (AgNPs-PANINTs) composite is used as a non-enzymatic nanobiosensor for detecting hydrogen peroxide (H2O2). The electrocatalytic activity for the reduction was strongly affected by the concentration of silver ammonia solution in the nanocomposites, with the best electrocatalytic activity observed for the composite of 6:1 volume ratios of PANI to Ag(NH3)2OH (0.04M). Field emission scanning electron microscope images and their size distribution diagrams indicated that using the silver ammonia complex instead of silver nitrate caused uniform distribution of nanometer-sized silver nanoparticles with a narrow size distribution in the composite. The corresponding calibration curve for the current response showed a linear detection range of 0.1-90mM (R2=0.9986), while the limit of detection was estimated to be 0.2μM at the signal to noise ratio of 3. © 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:816 / 823
相关论文
共 50 条
  • [41] One-step preparation of a composite consisting of graphene oxide, Prussian blue and chitosan for electrochemical sensing of hydrogen peroxide
    Gong, Heqing
    Sun, Muhua
    Fan, Runhua
    Qian, Lei
    MICROCHIMICA ACTA, 2013, 180 (3-4) : 295 - 301
  • [42] Layer-by-layer chitosan-decorated pristine graphene on screen-printed electrodes by one-step electrodeposition for non-enzymatic hydrogen peroxide sensor
    Zhu, Qin
    Liang, Bo
    Cai, Yu
    Cao, Qingpeng
    Tu, Tingting
    Huang, Bobo
    Fang, Lu
    Ye, Xuesong
    TALANTA, 2018, 190 : 70 - 77
  • [43] Non-enzymatic amperometric detection of hydrogen peroxide in human blood serum samples using a modified silver nanowire electrode
    Thirumalraj, Balamurugan
    Zhao, Duo-Han
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2016, 470 : 117 - 122
  • [44] One-step hydrothermal synthesis of CuS/MoS2 composite for use as an electrochemical non-enzymatic glucose sensor
    Sharma, Krishna Prasad
    Shin, Miyeon
    Awasthi, Ganesh Prasad
    Cho, Soonhwan
    Yu, Changho
    HELIYON, 2024, 10 (02)
  • [45] A Non-enzymatic Hydrogen Peroxide Sensor Based on CuO Nanoparticles/polyaniline on Flexible CNT Fiber Electrode
    Song, Min-Jung
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2023, 61 (02): : 196 - 201
  • [46] One-step hydrothermal green synthesis of silver nanoparticle-carbon nanotube reduced-graphene oxide composite and its application as hydrogen peroxide sensor
    Lorestani, Farnaz
    Shahnavaz, Zohreh
    Mn, Pooria
    Alias, Yatimah
    Manan, Ninie S. A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 389 - 398
  • [47] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Yu Zhang
    Chengyan Wang
    Feng Jia
    Microchimica Acta, 2012, 176 : 389 - 395
  • [48] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [49] Preparation of polyaniline-palladium composite microflakes by one-step interface polymerization method
    Li, Liang
    Yan, Guoping
    Wu, Jiangyu
    Yu, Xianghua
    Guo, Qingzhong
    Ma, Zhibin
    Huang, Zhiliang
    JOURNAL OF POLYMER RESEARCH, 2009, 16 (04) : 421 - 426
  • [50] Non-enzymatic electrochemical sensor based on Cu2O/AuCu/Cu composite for hydrogen peroxide detection
    Liang, Xiaoyu
    Li, Weixiang
    Han, Hongliang
    Ma, Zhanfang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 834 : 43 - 48