Design and construction of long-span single-layer dome structures by direct analysis

被引:5
|
作者
Liu Y.P. [1 ]
Pan S.J. [2 ]
Leung S.W.K. [2 ]
Chan S.L. [1 ]
机构
[1] Department of Civil and Environmental Engineering, The Hong Kong Polytechnic University
[2] Building Construction, China State Construction Engineering (Hong Kong) Limited
关键词
construction sequence; dome structures; long-span structures; off-loading analysis; Second-order direct analysis;
D O I
10.1080/1023697X.2017.1409663
中图分类号
学科分类号
摘要
Long-span roofs are widely used worldwide as they provide large internal spaces without obstructions like columns. In designing long-span roofs, the traditional design method faces many difficulties, such as uncertainty in buckling effective length. The advanced second-order direct analysis (SODA) method for design shows and has many advantages for structural safety and cost saving. In this paper, the SODA considering P-Δ and P-δ effects as well as initial imperfections is proposed for designing of long-span roofs and the assumption of effective length is no longer required. The application of this concept of SODA to the design of practical structures appears to be new and unique, especially on the aspects of design at the construction stages. Key considerations for the construction of long-span structures by SODA are first reported. The planning of the lifting procedure, temporary support system (TSS) and off-loading sequences for load transfer from a TSS to permanent structure is guided by SODA such that an economic design and safe construction can be achieved. A constructed long-span single-layer roof structure in Macau is used to demonstrate the validity, practicality, accuracy and reliability of the proposed method and is taken as an example of successful joint work for advanced design by academicians and engineers in practice. © 2018 The Hong Kong Institution of Engineers.
引用
收藏
页码:29 / 43
页数:14
相关论文
共 50 条
  • [21] Economical design for long-span soil - Metal structures
    Mohammed, H
    Kennedy, JB
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1996, 23 (04) : 838 - 849
  • [22] Study on Construction Molding Technology of Long-Span Space Truss Suspended Dome Structure
    Liu, Mingliang
    Zhao, Junhai
    Jiao, Yongkang
    Hui, Cun
    Zhou, Chunjuan
    Yang, Xiao
    Zhang, Yupeng
    METALS, 2023, 13 (01)
  • [23] Energy-based seismic stability analysis of single-layer reticulated dome structures
    Xu, Jun
    Sun, Rui
    THIN-WALLED STRUCTURES, 2020, 154
  • [24] Wind-induced dynamic behavior and its load estimation of a single-layer latticed dome with a long span
    Uematsu, Y
    Kuribara, O
    Yamada, M
    Sasaki, A
    Hongo, T
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2001, 89 (14-15) : 1671 - 1687
  • [25] SEISMIC RESILIENCE ASSESSMENT OF A SINGLE-LAYER RETICULATED DOME DURING CONSTRUCTION
    Zhang, Tian-Long
    Zhao, Jun-Yan
    ADVANCED STEEL CONSTRUCTION, 2023, 19 (01): : 77 - 85
  • [26] Seismic response modification factors of single-layer diamatic dome structures
    Abdollahi, Ali
    Poursha, Mehdi
    Abedi, Karim
    ENGINEERING STRUCTURES, 2024, 310
  • [27] Analysis of Nonlinear Buckling of a Long-span Elliptic Paraboloid Suspended Dome Structure
    Jiang, Zhengrong
    Shi, Kairong
    Gao, Xiaonan
    Chen, Qingjun
    ADVANCES IN CIVIL INFRASTRUCTURE ENGINEERING, PTS 1 AND 2, 2013, 639-640 : 191 - 197
  • [28] Seismic response analysis of long-span arch shell steel dome structure
    Ren, De-Bin
    Zhao, Wen-Ting
    Ren, D.-B. (cedbren@sjzu.edu.cn), 1600, Tsinghua University (31): : 166 - 170
  • [29] Analysis on mechanical properties of long-span ellipsoidal cable-supported dome
    Feng, Yuan
    Xia, Xun
    Wang, Liwei
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (05): : 63 - 69
  • [30] The Investigation of Long-span Double-layer Reticulated Dome Greenhouse's Dynamic Characteristics
    Kong, Bo-Wen
    Qiao, Ke
    Yuan, Jun
    INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS ENGINEERING (ICMME 2014), 2014, : 338 - 343