Effect of contamination component on ac flashover performance of insulator string XP-160

被引:0
|
作者
机构
[1] Zhang, Zhijin
[2] Zhang, Dongdong
[3] 1,Yuan, Chao
[4] Jiang, Xingliang
[5] Liu, Xiaohuan
[6] Hu, Jianlin
来源
Zhang, Zhijin | 1970年 / Science Press卷 / 40期
关键词
Impurities - Pollution - Salt deposits - Calcium sulfate - Insulator contamination - Flashover;
D O I
10.13336/j.1003-6520.hve.2014.07.007
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Influence of Composite Insulator Shed Design on Contamination Flashover Performance at High Altitudes
    Zhang, Fuzeng
    Wang, Liming
    Guan, Zhicheng
    MacAlpine, Mark
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (03) : 739 - 744
  • [22] Equivalence of pollution simulation methods for AC flashover performance of iced composite insulator
    Jiang, Xing-Liang
    Zhang, Zhi-Jin
    Hu, Jian-Lin
    Yang, Jian-Lan
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (13): : 115 - 120
  • [23] Effect of inverted T arrangement on AC pollution flashover characteristics of insulator strings
    Jiang, Xingliang
    Ren, Xiaodong
    Wang, Han
    Han, Xingbo
    Bi, Conglai
    Li, Zhiyu
    Hou, Ledong
    HIGH VOLTAGE, 2019, 4 (02) : 97 - 104
  • [24] AC pollution flashover performance of insulator strings partially treated with semiconductive RTV coating
    Jia, Zhidong
    Hu, Yarong
    Guan, Zhicheng
    Wei, Xiaoxing
    Dianwang Jishu/Power System Technology, 2015, 39 (09): : 2633 - 2639
  • [25] EFFECT OF CONFIGURATION ON CONTAMINATED INSULATOR STRING PERFORMANCE
    FLUGUM, RW
    KARCIC, AJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (01): : 336 - &
  • [26] DC Flashover Performance of Insulator String with Fan-shaped Non-uniform Pollution
    Zhang, Zhijin
    Zhang, Dongdong
    Zhang, Wei
    Yang, Chao
    Jiang, Xingliang
    Hu, Jianlin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 177 - 184
  • [27] Effect of Environment Factors on AC Flashover Performance of 3 Units of Polluted Insulator Strings under Natural Fog Condition
    Dong, Bingbing
    Jiang, Xingliang
    Zhang, Zhijin
    Hu, Jianlin
    Hu, Qin
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) : 1926 - 1932
  • [28] DC flashover performance and voltage correction of iced XZP-160 insulator at low atmospheric pressure
    Wu, Lihui
    Jiang, Xingliang
    Xiong, Qixin
    Sima, Wenxia
    Sun, Caixin
    Gaodianya Jishu/High Voltage Engineering, 2002, 28 (10):
  • [29] AC flashover performance of iced insulators string structured with alternately large and small diameter sheds
    Jiang, Xing-Liang
    Lu, Jie
    Du, Yuan
    Yuan, Ji-He
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2009, 29 (10): : 12 - 16
  • [30] Influence of T-Type Arrangement on Icing Process and AC Flashover Performance of Insulator Strings
    Jiang X.
    Bi C.
    Wang H.
    Yang Z.
    Han X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (17): : 3713 - 3720