The study described in this paper refers to seismic assessment and retrofit of an existing 10-storey reinforced concrete office building designed and built at the beginning of the 20 century. When this building with a height of 38.95 m was completed it was the highest in downtown Montreal. According to FEMA 547 classification, the typology of this building structure is associated to model building type C3. Consequently, this type of non-ductile frame building with an insignificant amount of masonry walls is relatively weak and unable to carry the seismic forces when subjected to ground motions from a potential earthquake magnitude. The main deficiencies of this structural system are: poor lateral confinement and shear resistance of columns, the location of lap splices and the number of reinforcing bars often inadequate, the lack of confinement and shear reinforcement in joints, poor anchorage of longitudinal reinforcement of beams into joints and shear resistance of beams. Due to lack of seismic detailing, the common retrofit measure recommended in ASCE/SEI 41–13 for this building is to add new lateral force-resisting systems designed according to current code and standard provisions. Hence, in this case, the most cost-effective retrofit solution is to add a steel structure designed to withstand seismic forces while responding to serviceability criteria required to preserve the non-reinforced masonry facades facing the main streets and the facades ornaments. © 2017 Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG, Berlin.
引用
收藏
页码:4522 / 4531
相关论文
共 50 条
  • [31] Characteristics of air pollutant dispersion around a high-rise building
    Zhang, Y.
    Kwok, K. C. S.
    Liu, X. -R
    Niu, J. -L.
    ENVIRONMENTAL POLLUTION, 2015, 204 : 280 - 288
  • [32] Sustainable building retrofit model for high-rise, high-density city: a case in Hong Kong
    He, Qiong
    Hossain, Md. Uzzal
    Ng, S. Thomas
    Augenbroe, Godfried
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING SUSTAINABILITY, 2021, 174 (02) : 69 - 82
  • [33] Energy Retrofit and Fire Protection in Existing High-Rise Residential Buildings: A Case Study in Modena (Italy)
    Guardigli, Luca
    Barbolini, Fausto
    SUSTAINABILITY IN ENERGY AND BUILDINGS 2022, 2023, 336 : 324 - 336
  • [34] Repair and retrofit of a modern high-rise curtain wall
    Weinstein, JS
    Del Rosso, AL
    WATER PROBLEMS IN BUILDING EXTERIOR WALLS: EVALUATION, PREVENTION, AND REPAIR, 1999, 1352 : 317 - 329
  • [35] Design & renovation of a high-rise retrofit eifs cladding
    French, W.R.
    Interface (Raleigh, North Carolina), 2000, 18 (11): : 4 - 15
  • [36] Wind interference effects of high-rise building on low-rise building with flat roof
    Chen, Bo
    Shang, Luxi
    Qin, Mengyi
    Chen, Xinzhong
    Yang, Qingshan
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2018, 183 : 88 - 113
  • [38] Structural vibration passive control and economic analysis of a high-rise building in Beijing
    Yongqi Chen
    Tiezhu Cao
    Liangzhe Ma
    Chaoying Luo
    Earthquake Engineering and Engineering Vibration, 2009, 8 : 561 - 568
  • [39] Wind-induced vibration control of high-rise building with random parameters
    Huang, B
    Qu, WL
    ADVANCES IN STOCHASTIC STRUCTURAL DYNAMICS, 2003, : 199 - 206
  • [40] Vibration Attenuation in a High-Rise Hybrid-Timber Building: A Comparative Study
    Chapain, Suvash
    Aly, Aly Mousaad
    APPLIED SCIENCES-BASEL, 2023, 13 (04):