Simulation method of column behavior on long gap free arc in air

被引:4
|
作者
Tanaka, Shin-Ichi [1 ,2 ]
Matsumura, Toshiro [1 ]
机构
[1] Department of Electrical Engineering and Computer Science, Nagoya University Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
[2] Electric Power Engineering Research Lab., Central Research Institute of Electric Power Industry, 2-6-1 Nagasaka, Yokosuka 240-0196, Japan
关键词
D O I
10.1541/ieejpes.129.921
中图分类号
学科分类号
摘要
A simulation model for the column behavior on the long gap free arcs in air was constructed. In this model, the current path of the arc column was assumed to be a string of many nodes separated by very short intervals. Concerning the operation of the nodes, we considered the continuous motion due to the Lorentz force and the instantaneous motion due to the partial shorting, and introduced two special parameters to control them. One parameter was used to control the velocity of the continuous motion of the arc column, while the other was used to control the occurrence frequency of the partial shorting on the arc column. To evaluate the validity of the constructed simulation model, the column behaviors on DC free arcs with currents of 100, 500 and 2000 A respectively on a gap length of 1. 6 m were simulated with giving various values to two special parameters. Consequently, it was proved that the simulation results with certain suitable values on two special parameters showed similar column behaviors to the actual characteristics and that the constructed simulation model was valid. © 2009 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:921 / 928
相关论文
共 50 条
  • [1] Internal voltage gradient and behavior of column on long-gap DC free arc
    Tanaka, SI
    Sunabe, KY
    Goda, Y
    ELECTRICAL ENGINEERING IN JAPAN, 2003, 144 (03) : 8 - 16
  • [2] Long arc in free air elongation effects modeling and simulation
    Terzija, VV
    Koglin, HJ
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2002, 12 (06): : 419 - 425
  • [3] Resistance characteristics of arc in long air gap
    Yu, Zhanqing
    Yu, Junjie
    Zeng, Rong
    Chen, He
    Peng, Xiang
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (08): : 1881 - 1885
  • [4] Movement simulation of long electric arc along the surface of insulator string in free air
    Gu, SQ
    He, JL
    Zhang, B
    Xu, GZ
    Han, SJ
    IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (04) : 1359 - 1362
  • [5] Long arc in free air: laboratory testing, modelling, simulation and model-parameters estimation
    Terzija, VV
    Koglin, HJ
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2002, 149 (03) : 319 - 325
  • [6] Testing, modeling and simulation of long arc in still air
    Terzija, VV
    Koglin, HJ
    2001 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-3, 2001, : 1140 - 1145
  • [7] DIELECTRIC RECOVERY OF HEAVY-CIRCUIT ARC IN A LONG AIR GAP
    TERASE, H
    SADAMOTO, K
    HASHIMOT.Y
    ELECTRICAL ENGINEERING IN JAPAN, 1968, 88 (07) : 80 - &
  • [8] Dynamic characters research of air arc at low current in long gap
    Yan, Xianglian
    Chen, Weijiang
    Wang, Chengyu
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2009, 24 (11): : 165 - 171
  • [9] BEHAVIOR OF THIN ARC PLASMA IN A SELF-CROWBAR AIR GAP
    IKUTA, K
    UENO, I
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1983, 22 (08): : 1299 - 1301
  • [10] Laboratory testing and dynamic modeling of long arc in free air
    Terzija, VV
    Koglin, HJ
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 897 - 902