Asymmetric combustion characteristics and NOx emissions of a down-fired 300MWe utility boiler at different boiler loads

被引:0
|
作者
School of Energy Science and Engineering, Harbin Institute of Technology, 92 West Dazhi Street, Harbin 150001, China [1 ]
机构
来源
Energy | 1600年 / 1卷 / 580-590期
关键词
Engineering Village;
D O I
暂无
中图分类号
学科分类号
摘要
Aerodynamic field - Asymmetric combustions - Boiler efficiency - Boiler loads - Down-fired boiler - Exhaust gas temperatures - Pulverized coals - Small-scale modeling
引用
收藏
相关论文
共 50 条
  • [31] Improving the combustion performance of a 660MWe down-fired utility boiler by adopting high efficiency combustion technologies
    Li, Zhengqi
    Liu, Guangkui
    Zhu, Qunyi
    Chen, Zhichao
    Ren, Feng
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [32] Effect of separated over-fire air angle on combustion and NOx emissions in a down-fired utility boiler with a novel combustion system
    Ma, Lun
    Yu, Shenghui
    Fang, Qingyan
    Zhang, Cheng
    Chen, Gang
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 138 : 57 - 66
  • [33] Numerical investigation on combustion and NOx emissions of a down-fired 350 MWe utility boiler with multiple injection and multiple staging: Effect of the air stoichiometric ratio in the primary combustion zone
    Kuang, Min
    Zhu, Qunyi
    Li, Zhengqi
    Zhang, Xiang
    FUEL PROCESSING TECHNOLOGY, 2013, 109 : 32 - 42
  • [34] Effect of the separated overfire air location on the combustion optimization and NOx reduction of a 600 MWe FW down-fired utility boiler with a novel combustion system
    Ma, Lun
    Fang, Qingyan
    Tan, Peng
    Zhang, Cheng
    Chen, Gang
    Lv, Dangzhen
    Duan, Xuenong
    Chen, Yiping
    APPLIED ENERGY, 2016, 180 : 104 - 115
  • [35] Numerical Simulation of Combustion Characteristics and NOx Emissions in a 300 MWe Utility Boiler with Different Outer Secondary-Air Vane Angles
    Zeng, Lingyan
    Li, Zhengqi
    Zhao, Guanbo
    Shen, Shanping
    Zhang, Fucheng
    ENERGY & FUELS, 2010, 24 (10) : 5349 - 5358
  • [36] Impact of the Overfire Air Location on Combustion Improvement and NOx Abatement of a Down-Fired 350 MWe Utility Boiler with Multiple Injection and Multiple Staging
    Kuang, Min
    Li, Zhengqi
    Xu, Shantian
    Zhu, Xingying
    Zhang, Yan
    Zhu, Qunyi
    ENERGY & FUELS, 2011, 25 (10) : 4322 - 4332
  • [37] Combustion characteristics and NOx emissions of two kinds of swirl burners in a 300-MWe wall-fired pulverized-coal utility boiler
    Li, Zhengqi
    Jing, Jianping
    Chen, Zhichao
    Ren, Feng
    Xu, Bin
    Wei, Hongda
    Ge, Zhihong
    COMBUSTION SCIENCE AND TECHNOLOGY, 2008, 180 (07) : 1370 - 1394
  • [38] Experimental characterization of anthracite combustion and NOx emission for a 300-MWe down-fired boiler with a novel combustion system: Influence of primary and vent air distributions
    Wang, Qingxiang
    Chen, Zhichao
    Han, Hui
    Zeng, Lingyan
    Li, Zhengqi
    APPLIED ENERGY, 2019, 238 : 1551 - 1562
  • [39] A novel coal combustion technology for a down-fired boiler: Aerodynamic characteristics
    Yang, Weijuan
    Yang, Wenchuang
    Zhou, Zhijun
    Zhou, Junhu
    Huang, Zhenyu
    Liu, Jianzhong
    Cen, Kefa
    FUEL PROCESSING TECHNOLOGY, 2014, 118 : 90 - 97
  • [40] Effect of burner location on flow-field deflection and asymmetric combustion in a 600 MWe supercritical down-fired boiler
    Kuang, Min
    Yang, Guohua
    Zhu, Qunyi
    Ti, Shuguang
    Wang, Zhenfeng
    APPLIED ENERGY, 2017, 206 : 1393 - 1405