An Optimal Sizing of Small Hydro/PV/Diesel Generator Hybrid System for Sustainable Power Generation

被引:0
|
作者
Hafis A. [1 ]
Adamu A.S. [1 ]
Jibril Y. [1 ]
Abdulwahab I. [1 ]
机构
[1] Ahmadu Bello University, Zaria
关键词
Cost of energy; Dragonfly Algorithm; Renewable energy sources; TORSCHE algorithm;
D O I
10.25103/jestr.166.01
中图分类号
学科分类号
摘要
Concerns surrounding the environment along with inadequate energy supply and high cost of same are responsible for pollution, high energy demand, unpredictable and uneconomical power generation. These have contributed to the widespread agreement that sustainable renewable energy sources (RES) must be developed, particularly in isolated villages where expanding the grid may be challenging and financially unviable for power corporations. As a result, in order to effectively and cheaply utilize the plentiful renewable energy resources, an optimal sizing approach is required. This study is aimed at investigating the economic performance of the hybrid system of a stand-alone Small Hydropower/PV/Diesel generator with battery electricity production. The cost function was minimized using Dragonfly Algorithm (DA) in order to minimize the Cost of Energy (COE) generation. The decision variables are the number of small hydro turbines (NSHP), number of solar panels (NPV), number of batteries (NBATT) and the capacity of Diesel generator (PDG). The developed method is applied to a typical Kiri village in Shelleng Local Government area of Adamawa State. For uniformity, the hourly solar irradiance data were created by converting the monthly average solar irradiance data. A dragonfly optimization technique was utilized to reach an optimum solution for the hybrid system. The result obtained showed that the system components: small Hydropower, solar PV and Diesel generator were able to generate electrical power of 5,783,600 W, 56,259 W and 5.2941e-05 W respectively to meet the energy demand. Results obtained from the developed scheme were compared with those obtained when TORSCHE algorithm was used in optimizing the hybrid system. It was observed that a total energy cost of $5,224,500 was obtained for the developed technique while $5,839,600 was obtained as the total cost for the TORSCHE model. This showed that the developed scheme outperformed the system output from the TORSCHE algorithm in terms of cost of energy by 89.46%. © 2023 School of Science, IHU. All Rights Reserved.
引用
收藏
页码:1 / 7
页数:6
相关论文
共 50 条
  • [21] Research on Control Strategies of Small-Hydro/PV Hybrid Power System
    Sheng, Wu Chun
    Hua, Liao
    Long, Yang Zi
    Bo, Wang Yi
    Chang, Peng Yan
    Hua, Xu Hong
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 1413 - +
  • [22] Optimal sizing of a hybrid PV, Wind and Micro-Hydro system for rural electrification using LPO
    Panda, Riti
    Nayak, Manas Ranjan
    2017 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT), 2017,
  • [23] Optimal sizing of hybrid energy storage sub-systems in PV/diesel ship power system using frequency analysis
    Wen, Shuli
    Lan, Hai
    Yu, David. C.
    Fu, Qiang
    Hong, Ying-Yi
    Yu, Lijun
    Yang, Ruirui
    ENERGY, 2017, 140 : 198 - 208
  • [24] Optimal Sizing of Diesel-PV Hybrid System for Continous Power Supply for Public Places:Case of Ouando Market in Benin
    Koffi, Chetangny Patrice
    Sossou, Houndedako
    Jacques, Aredjodoun Gbadebo
    Jawad, Sikirou
    Victor, Zogbochi
    Didier, Chamagne
    Gerald, Barbier
    Jean-Marie, Zonou
    Antoine, Vianou
    2019 IEEE AFRICON, 2019,
  • [25] Optimal sizing of distributed generation considering uncertainties in a hybrid power system
    Abd-el-Motaleb, A. M.
    Bekdach, Sarah Kazem
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 82 : 179 - 188
  • [26] Optimal design of hybrid PV-diesel-battery system for power generation in Moradabad district of Uttar Pradesh, India
    Agarwal, Nitin
    Kumar, Anoop
    Varun
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2012, 33 (01) : 23 - 34
  • [27] A Frequency-Control Approach by Photovoltaic Generator in a PV-Diesel Hybrid Power System
    Datta, Manoj
    Senjyu, Tomonobu
    Yona, Atsushi
    Funabashi, Toshihisa
    Kim, Chul-Hwan
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (02) : 559 - 571
  • [28] Optimal Sizing of Hybrid Wind-PV-Tide System
    Park, Kun Hyun
    Kang, Chul Ung
    Lim, Jong Hwan
    COMPUTERS, NETWORKS, SYSTEMS, AND INDUSTRIAL ENGINEERING 2011, 2011, 365 : 209 - 218
  • [29] Hydro-PV-Wind-Battery-Diesel Based Stand-Alone Hybrid Power System
    Rahman, M. M. Atiqur
    Al Awami, Ali T.
    Rahim, A. H. M. A.
    2014 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION & COMMUNICATION TECHNOLOGY (ICEEICT 2014), 2014,
  • [30] A methodology or optimal sizing of autonomous hybrid PV/wind system
    Diaf, S.
    Diaf, D.
    Belhamel, M.
    Haddadi, M.
    Louche, A.
    ENERGY POLICY, 2007, 35 (11) : 5708 - 5718