Single-Phase Open-Circuit Fault-Tolerant Direct Torque Control for Dual Three-Phase PMSM Based on SVPWM

被引:0
|
作者
Liu, Yu [1 ]
Huang, Sheng [2 ]
Liao, Wu [2 ]
Wang, Shaojie [1 ]
Tang, Hongwei [1 ]
Liang, Ge [2 ]
Luo, Derong [2 ]
Wu, Xuan [2 ]
Huang, Shoudao [2 ]
机构
[1] Shaoyang Univ, Coll Elect Engn, Shaoyang 422099, Peoples R China
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual three-phase permanent magnet synchronous motor (DTP-PMSM); fault-tolerant DTC (FT-DTC); single-phase open-circuit fault; space vector pulsewidth modulation (SVPWM); DRIVES; MACHINE;
D O I
10.1109/JESTPE.2024.3449323
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High reliability is one of the primary advantages of the dual three-phase permanent magnet synchronous motor (DTP-PMSM). However, the single-phase open-circuit fault in the DTP-PMSM drive suffers from large current harmonics and significant torque ripple. To solve these problems, a fault-tolerant direct torque control (FT-DTC) strategy based on space vector pulsewidth modulation (SVPWM) is proposed in this article. First, the component of stator flux on the ss-axis is modified under postfault. Based on this modified stator flux on the ss-axis, the stator current and the stator flux maintain the same circular trajectory both pre- and postfault. Second, the reference voltage is derived based on the relationship between the stator flux and the stator voltage. Then, the closed-loop controller on the z-axis is introduced to suppress current harmonics caused by factors such as dead time and back electromotive force (EMF) distortion. The output of the closed-loop controller is the harmonic voltage. Furthermore, a novel SVPWM technique is designed to modulate the reference voltage and harmonic voltage. Finally, experimental results demonstrate that the proposed FT-DTC strategy based on SVPWM can achieve high-performance operation under singlephase open-circuit fault.
引用
收藏
页码:5235 / 5245
页数:11
相关论文
共 50 条
  • [31] Postfault Control and Harmonic Current Suppression for a Symmetrical Dual Three-Phase SPMSM Drive Under Single-Phase Open-Circuit Fault
    Liang, Zhe
    Liang, Deliang
    Kou, Peng
    Jia, Shaofeng
    IEEE ACCESS, 2020, 8 (08): : 67674 - 67686
  • [32] Fault-Tolerant Control Strategy with Asymmetric Phase Currents for Single to Four-Phase Open-Circuit Faults of Six-Phase PMSM
    Huang, Chen
    Zhou, Lidan
    Cao, Zujia
    Yao, Gang
    ENERGIES, 2021, 14 (11)
  • [33] Direct Torque Control of Three-Phase PMSM with One Switch of Inverter Open Fault
    Moujahed, Mongi
    Ben Azza, Hechmi
    Jemli, Mohamed
    Boussak, Mohamed
    201415TH INTERNATIONAL CONFERENCE ON SCIENCES & TECHNIQUES OF AUTOMATIC CONTROL & COMPUTER ENGINEERING (STA'2014), 2014, : 400 - 404
  • [34] Fault Tolerant Capability of Deadbeat - Direct Torque and Flux Control for Three-Phase PMSM Drives
    Pulvirenti, M.
    Scarcella, G.
    Scelba, G.
    Lorenz, R. D.
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [35] Three-phase Motor Drive Topology with the Fault-tolerant Capability of Open-circuit on the Multiplexing Bridge
    Sun, Xiangwen
    Liu, Zicheng
    Li, Zhekai
    Sun, Qianchen
    Li, An
    Jiang, Dong
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 5043 - 5047
  • [36] Rotor-Flux Observer Based Sensorless Control of Five-Phase Fault-Tolerant PMSM with Open-Circuit Fault
    Zhou H.
    Ye C.
    Chen C.
    Zhang D.
    Chen Q.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (02): : 422 - 434
  • [37] Fault-Tolerant Control for Single-Phase Open-Circuit and Short-Circuit Fault in Five-Phase PMSM With Third-Order Harmonic Back EMF Using Coefficients Reconfiguration
    Wang, Huanran
    Gu, Chunyang
    Zhao, Weiduo
    Wang, Shuo
    Zhang, Xiaochen
    Buticchi, Giampaolo
    Gerada, Chris
    Zhang, He
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2024, 39 (01) : 782 - 792
  • [38] Sensorless Speed Control of Five-Phase PMSM Drives in Case of a Single-Phase Open-Circuit Fault
    Kamel Saleh
    Mark Sumner
    Iranian Journal of Science and Technology, Transactions of Electrical Engineering, 2019, 43 : 501 - 517
  • [39] Sensorless Speed Control of Five-Phase PMSM Drives in Case of a Single-Phase Open-Circuit Fault
    Saleh, Kamel
    Sumner, Mark
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2019, 43 (03) : 501 - 517
  • [40] Open-Circuit Fault-Tolerant Control for a Three-Phase Current-Fed Dual Active Bridge DC-DC Converter
    Tat-Thang Le
    Minh-Khai Nguyen
    Truong-Duy Duong
    Wang, Caisheng
    Choi, Sewan
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (02) : 1586 - 1596