Reliability Analysis of Axial Compressive Strength of Concrete-Filled Steel Tube (CFST) under Coupled Corrosion and Load Effects

被引:1
|
作者
Ma, Dan-Yang [1 ,2 ]
Ma, Shuai [1 ]
Xu, Li-Yan [1 ,2 ]
机构
[1] Beihang Univ, Sch Transportat Sci & Engn, Beijing 100191, Peoples R China
[2] Minist Educ, Key Lab Intelligent Transportat Technol & Syst, Beijing 100191, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
concrete-filled steel tube; parametric modelling; stochastic-based modelling; axial compressive strength; reliability index; BEHAVIOR; COLUMNS;
D O I
10.3390/buildings14103205
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a finite element analysis (FEA) of and reliability study on concrete-filled steel tube (CFST) members under the combined effects of corrosion and compressive loading. First, a stochastic-based FE model is established through the proposed secondary development program based on ABAQUS 2021 software. The model could account for the uncertainties of material, geometric, and corrosion effect on CFST members. The reliability of the built model was validated through experimental data of corroded CFST members under compression loading. Subsequently, the compressive performance of CFST under a combination of corrosion and loading was further investigated by numerical parameter analysis. A total of 1800 models were created to clarify the coupling mechanism among the core concrete strength, the steel tube strength, the steel ratio, and the maximum strength of the CFST member. Three theoretical formulas presented in classical design standards were used to calculate the axial compressive strength of the corroded CFST, and the uncertainty parameters mu kp and delta kp were also obtained for the discussed design formulas. Finally, the First Order and Second Moment (FOSM) method was employed to estimate the reliability indices beta across different standards. The calculations revealed that the reliability indices beta according to European standard ranges from 2.93 to 5.52, with some results falling below the target reliability index beta T of 3.65. In addition, the multi-parameter coupling effects on reliability index beta were investigated, and the main influencing factors were obtained. By leveraging the reliability analysis, reasonable design requirements can be proposed for CFST members under the coupling effects of corrosion and external load, which provides a design basis for the CFST member.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Strength and Axial Behavior of Cellular Lightweight Concrete-Filled Steel Rectangular Tube Columns under Axial Compression
    Thumrongvut, Jaksada
    Tiwjantuk, Pavarate
    THERMEC 2018: 10TH INTERNATIONAL CONFERENCE ON PROCESSING AND MANUFACTURING OF ADVANCED MATERIALS, 2018, 941 : 2417 - 2422
  • [22] The unified theory for concrete-filled steel tube (CFST) columns under various loads
    Shantong, Zhong
    KuranovaS, Artiornas
    9TH INTERNATIONAL CONFERENCE: MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, VOLS 1-3, 2008, : 779 - 785
  • [23] Axial compressive behaviors of circular steel slag concrete-filled steel tube slender columns
    Lu, Linhan
    Liang, Tao
    Zhang, Tianhe
    Ren, Qingxin
    Wang, Qinghe
    Wang, Sheng
    STRUCTURAL CONCRETE, 2023, 24 (06) : 6953 - 6972
  • [24] Circular concrete-encased concrete-filled steel tube (CFST) stub columns subjected to axial compression
    Li, Yong-Jin
    Han, Lin-Hai
    Xu, Wu
    Tao, Zhong
    MAGAZINE OF CONCRETE RESEARCH, 2016, 68 (19) : 995 - 1010
  • [25] Axial strength of circular concrete-filled steel tube columns - DOE approach
    Chitawadagi, Manojkumar V.
    Narasimhan, Mattur C.
    Kulkarni, S. M.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (10) : 1248 - 1260
  • [26] Axial compressive performance of concrete-filled steel tube stub columns with high-strength spiral confined concrete core
    Feng, Peng
    Li, Zhiyuan
    Zou, Yichong
    Yang, Jia-Qi
    THIN-WALLED STRUCTURES, 2023, 185
  • [27] Creep computation module of self-stressing concrete-filled steel tube under axial load
    Xu, Lei
    Huang, Cheng-Kui
    Gao, Dan-Ying
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2009, 41 (10): : 118 - 122
  • [28] FINITE ELEMENT ANALYSIS OF HIGH-STRENGTH CONCRETE-FILLED HIGH-STRENGTH SQUARE STEEL TUBE MIDDLE LONG COLUMNS UNDER AXIAL LOAD
    Li, Guochang
    Chen, Yingxun
    Yang, Zhijian
    Chen, Bowen
    Cao, Wenzheng
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1015 - 1022
  • [29] Performance Analysis of Concrete-filled Steel Tube Column and Reinforced Concrete Column under Axial Compression
    Du, Chuang
    Yang, Xiaoming
    Li, Ningli
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 82 - 85
  • [30] Study of the concrete in reinforced concrete-filled steel tube column under axial loading
    Xiamuxi, Alifujiang
    Liu, Xiaorui
    Hasegawa, Akira
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 170