Relationship between transient enclosure voltage and very fast transient overvoltage generated during disconnector operations in gas insulated switchgear

被引:0
|
作者
Guan, Yonggang [1 ]
Cai, Yuanji [1 ]
Liu, Weidong [1 ]
Chen, Weijing [2 ]
机构
[1] State Key Laboratory of Control and Simulation of Power System and Generation Equipments, Department of Electrical Engineering, Tsinghua University, Beijing,100084, China
[2] State Grid Corporation of China, Beijing,100031, China
来源
Gaodianya Jishu/High Voltage Engineering | 2015年 / 41卷 / 12期
关键词
704.2 Electric Equipment - 706.1.2 Electric Power Distribution - 711 Electromagnetic Waves - 801.4.1 Electrochemistry - 802.2 Chemical Reactions;
D O I
10.13336/j.1003-6520.hve.2015.12.032
中图分类号
学科分类号
摘要
25
引用
收藏
页码:4097 / 4104
相关论文
共 50 条
  • [31] ESTIMATION OF FAST TRANSIENT OVERVOLTAGE IN GAS-INSULATED SUBSTATION
    YANABU, S
    MURASE, H
    AOYAGI, H
    OKUBO, H
    KAWAGUCHI, Y
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (04) : 1875 - 1882
  • [32] Differentiating/integrating system for the measurement of very fast transient overvoltage in gas-insulated substation
    Guangdong Power Test and Research, Inst, Guangzhou, China
    Zhongguo Dianji Gongcheng Xuebao, 5 (59-61, 29):
  • [33] Calculate Very Fast Transient Current by the Inverse Operation of the Transient Electromagnetic Near Field due to Switch Operation in Gas Insulated Switchgear
    Xin, Weifeng
    Zhang, Guogang
    Wang, Jianqiang
    Liu, Kai
    Geng, Yingsan
    Rong, Mingzhe
    IEICE TRANSACTIONS ON ELECTRONICS, 2014, E97C (09): : 888 - 893
  • [34] Characteristics of Planar Capacitor Sensors with Dielectric Window for Very Fast Transient Overvoltage Measurement in Gas Insulated Switchgears
    Ma, Guo-ming
    Li, Cheng-rong
    Chen, Wei-jiang
    Sun, Ze-lai
    Guo, Pan-hui
    Li, Zhi-bing
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 149 - 152
  • [35] Electromagnetic-circuit co-simulation of very fast transient overvoltage in gas-insulated switches
    Liu, Ying
    Chao, Hsuehyung
    Xie, Yongjun
    Wu, Dongwei
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2016, 11 : S11 - S16
  • [36] A calculation method of transient field under very fast transient over-voltage in gas insulated substation (GIS)
    Gao, YH
    Yuan, H
    Wang, EZ
    Cao, YD
    APPLIED ELECTROMAGNETICS (III), 2001, 10 : 215 - 218
  • [37] Research on Very Fast Transient Voltage of 330kV GIS Disconnector Operation
    Yue, Tong
    Qi, Wang
    Jin, Zhang
    Xiang, Liu
    2023 5TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES, 2023, : 94 - 98
  • [38] Experimental study of effect of Disconnector speed on Very Fast transient Over Voltages in a 420kV Gas Insulated Substation
    Rao, J. V. G. Rama
    Ramakrishna, A.
    JOURNAL OF ELECTRICAL SYSTEMS, 2020, 16 (02) : 142 - 151
  • [39] Disconnector switching induced transient voltage and radiated fields in a 1100 kV gas insulated substation
    Haseeb, M. A.
    Thomas, M. Joy
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 161 : 86 - 94
  • [40] The influence of gas insulated substation structural parameters on transient enclosure voltage waveform
    Han, Mingming
    Li, Qingquan
    Liu, Hongshun
    Yang, Luming
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (22): : 239 - 246