Simulation and Experimental Study on Heat Transfer Performance of Bionic Structure-Based Battery Liquid Cooling Plate

被引:0
|
作者
Wang, Zhizhong [1 ]
Liu, Dinghong [2 ]
Li, Zhaoyang [2 ]
Qi, Xin [2 ]
Wan, Chaoyi [1 ]
机构
[1] Jiangsu Univ Technol, Sch Automot & Traff Engn, Changzhou 213001, Peoples R China
[2] CATARC Automot Test Ctr Changzhou Co Ltd, Changzhou 213001, Peoples R China
来源
WORLD ELECTRIC VEHICLE JOURNAL | 2024年 / 15卷 / 10期
关键词
lithium-ion battery; bionic structure-based design; liquid cooling plate; numerical simulation; battery thermal management; THERMAL PERFORMANCE;
D O I
10.3390/wevj15100464
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study presents a bionic structure-based liquid cooling plate designed to address the heat generation characteristics of prismatic lithium-ion batteries. The size of the lithium-ion battery is 148 mm x 26 mm x 97 mm, the positive pole size is 20 mm x 20 mm x 3 mm, and the negative pole size is 22 mm x 20 mm x 3 mm. Experimental testing of the Li-ion battery's heat generation model parameters, in conjunction with bionic structure and micro-channel features, has led to the development of this innovative cooling system. The traditional bionic liquid cooling plate's structure is often singular; however, the flow path of the liquid cooling plate designed in this paper is based on the combination of the distribution of human blood vessel branches and the structure of insect wing veins. The external dimension of the liquid cooling plate is 152 mm x 100 mm x 6 mm (length x width x height). Utilizing numerical simulation and thermodynamic principles, we analyzed the heat transfer efficacy of the bionic liquid cooling module for power batteries. Specifically, we investigated the impact of varying coolant flow rates and the contact radius between flow channels on the thermal performance of the bionic battery modules. Our findings indicate that a liquid flow rate of 0.6 m/s achieves a stable maximum surface temperature and temperature differential across the bionic battery liquid cooling module, with a relatively low overall system power consumption, suggesting room for further enhancement of heat transfer performance. By augmenting the contact radius between flow channels, we observed an initial increase in the maximum surface temperature, temperature differential, and inlet-outlet pressure differential at a flow rate of 0.2 m/s. However, at flow rates equal to or exceeding 0.4 m/s, these parameters stabilized across different design Scenarios. Notably, the pump power consumption remained consistent across various scenarios and flow rates. This study's outcomes offer valuable insights for the development of liquid-cooled battery thermal management systems that are energy-efficient and offer superior heat transfer capabilities.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Numerical study on heat dissipation of double layer enhanced liquid cooling plate for lithium battery module
    Zhang, Bao
    Li, Yan
    Chen, Zhan-Feng
    Wang, Wen
    Shi, Guang
    Yang, He
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 206
  • [42] Battery module thermal management based on liquid cold plate with heat transfer enhanced fin
    Fu, Jiaqi
    Xu, Xiaoming
    Li, Renzheng
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (09) : 4312 - 4321
  • [43] Study on the cooling performance of a new secondary flow serpentine liquid cooling plate used for lithium battery thermal management
    Fan, Liyun
    Li, Jingxue
    Chen, Ya
    Zhou, Daquan
    Jiang, Zejun
    Sun, Jinwei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 218
  • [44] Optimal design of liquid cooling structure with bionic leaf vein branch channel for power battery
    Liu, Feifei
    Chen, Yangyang
    Qin, Wu
    Li, Jun
    APPLIED THERMAL ENGINEERING, 2023, 218
  • [45] Comparative investigation on heat transfer augmentation in a liquid cooling plate for rectangular Li-ion battery thermal management
    Abdulqader, Ammar Abdulhaleem
    Jaffal, Hayder Mohammad
    RESULTS IN ENGINEERING, 2024, 24
  • [46] A liquid cooling plate based on topology optimization and bionics simplified design for battery cooling
    Ren, Jisheng
    Qiu, Xianghui
    Wang, Shuangfeng
    JOURNAL OF ENERGY STORAGE, 2024, 102
  • [47] A new design of cooling plate for liquid-cooled battery thermal management system with variable heat transfer path
    Wu, Changkun
    Ni, Jimin
    Shi, Xiuyong
    Huang, Rong
    APPLIED THERMAL ENGINEERING, 2024, 239
  • [48] Experimental study on heat transfer performance outside the tube banks for evaporative cooling
    Gao, Ming
    Zhang, Li-Xin
    Yang, Mo
    Li, Zi-Jun
    Huang, Chen-Shi
    Huang, Jing-Shan
    Su, Yong-Qiu
    Fan, Zhi-Yuan
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2008, 29 (04): : 640 - 642
  • [49] Experimental Study on Impact of Installation Angle on Heat Transfer Performance of Spray Cooling
    Pang Liping
    Liu Zhixuan
    Jin Shicheng
    Ji Yibin
    Zhang Yu
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON LOGISTICS, ENGINEERING, MANAGEMENT AND COMPUTER SCIENCE, 2014, 101 : 250 - 253
  • [50] Experimental study on heat transfer performance of a novel compact spray cooling module
    Jiang, Li-Jia
    Jiang, Shou-Li
    Cheng, Wen-Long
    Nian, Yong-Le
    Zhao, Rui
    APPLIED THERMAL ENGINEERING, 2019, 154 : 150 - 156