Simultaneous voltammetry detection of guanine and adenine in human serum with a CQDs / AuNPs @ MWCNTs modified glassy carbon electrode

被引:0
|
作者
Jiang, Jiang [1 ]
Zhuang, Qizhao [1 ]
Deng, Shiting [1 ]
Kong, Dexian [1 ]
Chi, Yuwu [2 ]
机构
[1] College of Life Sciences, Fujian Agriculture and Forestry University, Fuzhou,350002, China
[2] Key Laboratory of Food Safety and Bioanalysis, Ministry of Education, School of Chemistry, Fuzhou University, Fuzhou,350108, China
关键词
Fiber optic sensors - Glass - Glass membrane electrodes - Metal nanoparticles - Multiwalled carbon nanotubes (MWCN) - Nanocrystals - Positive ions - Semiconductor quantum dots;
D O I
10.13595/j.cnki.issn1000-0720.2021.070905
中图分类号
学科分类号
摘要
A modified glass carbon electrode (GCE) based on carbon quantum dots (CQDs) and gold nanoparticles (AuNPs)@ hydroxylated multi-wall carbon nanotubes (MWCNT-OHs) composite was fabricated and then employed to the selective and simultaneous determination of guanine and adenine. Compared with the other electrodes, the as prepared CQDs/AuNPs@ MWCNTs-OH modified electrode gave the highest peaks current and best peaks potential resolution. The electrochemical behaviors of guanine and adenine on the electrode were carefully investigated, and the results showed that, under the optimal condition, the oxidation peak currents concentrations of the analytes were linear with their concentrations in the range of 1-200 μmol/L and 2. 0-80 μmol/L, with the detection limits of 0. 9 and 1. 8 μmol/L for guanine and adenine, respectively. The modified electrode was used to simultaneous electrochemical analysis of GA and AE in human serum samples. The recoveries were between 90. 4%-107. 4%, which proved that the modified electrode was effective in biological samples. © 2021, Youke Publishing Co.,Ltd. All rights reserved.
引用
收藏
页码:1419 / 1424
相关论文
共 50 条
  • [21] Simultaneous determination of epinephrine and uric acid at poly (guanine) modified glassy carbon electrode
    Department of Chemistry and Chemical Engineering, Heze University, Daxue Road No.1, Heze
    274015, China
    Electrochem, 1600, 6 (434-439): : 434 - 439
  • [22] Growth of monolayer and multilayer graphene on glassy carbon electrode for simultaneous determination of guanine, adenine, thymine, and cytosine
    Qin, Junqing
    Gao, Suhua
    Li, Hongji
    Li, Cuiping
    Li, Mingji
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 895
  • [23] Detection of Sunset Yellow by Adsorption Voltammetry at Glassy Carbon Electrode Modified with Chitosan
    Pena-Gonzalez, Andres
    Garcia-Beltran, Olimpo
    Nagles, Edgar
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (05): : 5005 - 5015
  • [24] Simultaneous Determination of Benserazide and Levodopa in Pharmaceutical Tablet, Human Serum and Urine Sample by Differential Pulse Voltammetry Using Modified Glassy Carbon Electrode
    Naushad, Mu.
    Gupta, V. K.
    Wabaidur, S. M.
    Alothman, Z. A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (01): : 297 - 311
  • [25] Simultaneous Determination of Dihydroxybenzene Isomers by MWCNTs-NTiO2 Modified Glassy Carbon Electrode
    Wei, Chun
    Zhao, Yuyan
    Huo, Jichuan
    Yang, Qiuxia
    Hu, Chengyao
    Zhang, Ying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (02): : 1421 - 1433
  • [26] Simultaneous determination of adenine and guanine utilizing PbO2-carbon nanotubes-ionic liquid composite film modified glassy carbon electrode
    Liu, Tao
    Zhu, Xiangbin
    Cui, Lin
    Ju, Peng
    Qu, Xiangjin
    Ai, Shiyun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 651 (02) : 216 - 221
  • [27] Enhancing dopamine detection using a glassy carbon electrode modified with MWCNTs, quercetin, and Nafion®
    Chen, Po-Yen
    Vittal, R.
    Nien, Po-Chin
    Ho, Kuo-Chuan
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (12): : 3504 - 3509
  • [28] An electrochemical sensor for the determination of tartrazine based on CHIT/GO/MWCNTs/AuNPs composite film modified glassy carbon electrode
    Rovina, Kobun
    Siddiquee, Shafiquzzaman
    Md Shaarani, Sharifudin
    DRUG AND CHEMICAL TOXICOLOGY, 2021, 44 (05) : 447 - 457
  • [29] Simultaneous detection of guanine, adenine, thymine, and cytosine at polyaniline/MnO2 modified electrode
    Prathap, M. U. Anu
    Srivastava, Rajendra
    Satpati, Biswarup
    ELECTROCHIMICA ACTA, 2013, 114 : 285 - 295
  • [30] Electrochemical behaviors and simultaneous determination of guanine and adenine based on highly ordered Pd-nanowire arrays-modified glassy carbon electrode
    Zhang, Min
    Gan, Feng
    Cheng, Faliang
    ANALYTICAL METHODS, 2015, 7 (12) : 4988 - 4994