Exploring a Multizone To Variable Volume HVAC Controls Retrofit

被引:0
|
作者
Westervelt, Eileen T.
Bush, Joseph
Schwenk, David M.
机构
关键词
Cooling; -; Retrofitting;
D O I
暂无
中图分类号
学科分类号
摘要
The U.S. Department of Defense (DOD) has thousands of 10 to 40+ year old multizone air-handling units (AHUs) in operation. These constant volume, variable temperature units are quick to meet space temperature needs, but they can be very energy inefficient. Multizone units deliver a constant volume of air to the building zones serviced, regardless of the actual cooling, heating and ventilation requirements of each zone. Further, the conventional two-deck multizone uses continuous, simultaneous operation of the heating and cooling coils, even when additional heating or cooling is not needed. Modern alternative system replacements (such as variable air volume systems) help address these inefficiencies but are costly and disruptive to install. This article presents an energy savings retrofit of the multizone control system that provides variable volume airflow at significantly lower expense and with less disturbance than a complete system change out. © 2022 Amer. Soc. Heating, Ref. Air-Conditoning Eng. Inc.. All rights reserved.
引用
收藏
页码:32 / 47
相关论文
共 50 条
  • [41] LOAD MANAGEMENT CONTROLS FOR HVAC AND R
    SPETHMANN, D
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1977, 19 (12): : 39 - 39
  • [42] Efficient HVAC controls: A symbolic approach
    Holub, Ondrej
    Zamani, Majid
    Abate, Alessandro
    2016 EUROPEAN CONTROL CONFERENCE (ECC), 2016, : 1159 - 1164
  • [43] RETROFIT CONTROLS IMPROVE TURBINE OPERATION
    DAHLBERG, S
    POWER ENGINEERING, 1986, 90 (05) : 47 - 47
  • [44] Optimal price based control of HVAC systems in multizone office buildings for demand response
    Amin, U.
    Hossain, M. J.
    Fernandez, E.
    JOURNAL OF CLEANER PRODUCTION, 2020, 270
  • [45] Managing a controls integration retrofit project
    Matrix Technologies Inc., Indianapolis, IN
    Iron Steel Technol., 2006, 5 (234-239):
  • [46] ENERGY START STOP AND FLUID-FLOW REGULATED CONTROL OF MULTIZONE HVAC SYSTEMS
    ZAHEERUDDIN, M
    ENERGY, 1993, 18 (03) : 289 - 302
  • [47] Field testing of advanced ventilation controls for variable air volume systems
    Mumma, SA
    Ke, YP
    ENVIRONMENT INTERNATIONAL, 1998, 24 (04) : 439 - 450
  • [48] Understanding the design intent of variable volume lab controls and pressurization systems
    Derse, W.A.
    TAB Journal, 2001, (SPRING.):
  • [49] Investigation of Energy Efficient Retrofit HVAC Systems for a University: Case Study
    Ligade, Jayraj
    Razban, Ali
    SUSTAINABILITY, 2019, 11 (20)
  • [50] HVAC System Air Leakage Requirements for Deep Energy Retrofit Projects
    Zhivov, Alexander
    Wray, Craig P.
    Mattsson, Lars-Ake
    Behls, Herman
    Smith, Larry
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 718 - 728