A New Hybrid DC Circuit Breaker Based on Thyristors

被引:0
|
作者
Xue S. [1 ]
Chen X. [1 ]
Liu B. [1 ]
Chen S. [1 ]
Zhao Y. [2 ]
Huang X. [2 ]
机构
[1] Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin
[2] Electric Power Research Institute of State Grid Tianjin Electric Power Company, Tianjin
来源
关键词
adaptive reclosing; DC circuit breaker (DCCB); equipment cost; flexible DC grid; pre-charging; thyristors;
D O I
10.13336/j.1003-6520.hve.20210909
中图分类号
学科分类号
摘要
In response to the grand goal of “carbon peaking and neutrality”, it is imperative to accelerate the development of flexible DC transmission technology. The hybrid DC circuit breaker (DCCB) is a key device to ensure the safe operation of the flexible DC power grid, and is used to realize fault isolation on the DC side. However, in most of the existing topologies, IGBTs are used as switching elements, which are costly and technically difficult. Therefore, a new hybrid DCCB based on thyristors is proposed in this paper. The circuit breaker mainly uses thyristors instead of IGBTs to switch the circuit state, which greatly reduces the cost and technical difficulty. In addition, the circuit breaker also has the functions of pre-charging and adaptive reclosing, which lays a good foundation for the large-scale application of the circuit breakers. Moreover, a detailed analysis and theoretical derivation of the working process of the proposed circuit breaker is carried out. Simulation models of single-ended equivalent and four-terminal DC power grids are built in PSCAD/EMTDC. The proposed circuit breaker is analyzed and verified in the simulation models, and the performance is compared with the typical circuit breakers. The simulation results verify the feasibility of the proposed circuit breaker and show that, on the basis of similar performance, the cost of the proposed DCCB is greatly reduced compared with the typical DCCBs. © 2022 Science Press. All rights reserved.
引用
收藏
页码:4568 / 4577
页数:9
相关论文
共 26 条
  • [11] LI Xiaodong, ZHANG Zheren, XU Zheng, Et al., Integrated HVDC circuit breaker with power flow control capability, Automation of Electric Power Systems, 44, 7, pp. 153-160, (2020)
  • [12] XU Jianzhong, LI Xinyu, SONG Bingqian, Et al., Composite DC power flow controller with fault current limiting and breaking capacity, Proceedings of the CSEE, 40, 13, pp. 4244-4255, (2020)
  • [13] HE J H, LUO Y P, LI M, Et al., A high-performance and economical multiport hybrid direct current circuit breaker, IEEE Transactions on Industrial Electronics, 67, 10, pp. 8921-8930, (2020)
  • [14] XU J Z, SONG B Q, LU Y, Et al., A multi-port current-limiting hybrid DC circuit breaker, IEEE Transactions on Power Delivery, 36, 3, pp. 1672-1682, (2021)
  • [15] ZHANG S, ZOU G B, WEI X Y, Et al., Diode-bridge multiport hybrid DC circuit breaker for multiterminal DC grids, IEEE Transactions on Industrial Electronics, 68, 1, pp. 270-281, (2021)
  • [16] ZHOU Wandi, WEI Xiaoguang, GAO Chong, Et al., Thyristor based hybrid arc-less high voltage direct current circuit breaker, Proceedings of the CSEE, 34, 18, pp. 2990-2996, (2014)
  • [17] ZHOU Meng, ZUO Wenping, LIN Weixing, Et al., Capacitor commutated DC circuit breaker and its application in DC grid, Proceedings of the CSEE, 37, 4, pp. 1045-1052, (2017)
  • [18] LAN Tongkun, LI Yinhong, DUAN Xianzhong, A novel voltage clamp type hybrid direct current circuit breaker based on thyristors, Proceedings of the CSEE, 39, 20, pp. 6159-6168, (2019)
  • [19] WU Dongyi, LI Jialong, XU Jianzhong, Et al., A novel capacitor-based HVDC circuit breaker topology, Journal of North China Electric Power University, 47, 6, pp. 10-19, (2020)
  • [20] WEI Xiaoguang, YANG Bingjian, HE Zhiyuan, Et al., Control strategy and physical dynamic simulation of cascaded full-bridge DC circuit breaker, Automation of Electric Power Systems, 40, 1, pp. 129-135, (2016)