Numerical analysis of fire behavior of concrete slabs in full-scale steel-frame structure

被引:0
|
作者
Wang Y. [1 ]
Guo W.-X. [1 ]
Li L.-Z. [1 ,2 ]
Jian X.-H. [3 ]
Ma S. [1 ]
Zhang G.-Y. [4 ]
Zhao H.-H. [1 ]
机构
[1] State Key Laboratory for Geomechanics and Deep Underground Engineering, China University of Mining & Technology, Xuzhou
[2] College of Civil Engineering, Tongji University, Shanghai
[3] Zhejiang Ruibangkete Testing Co. Ltd, Hangzhou
[4] China Academy of Building Research, Beijing
来源
Gongcheng Lixue/Engineering Mechanics | 2021年 / 38卷 / 07期
关键词
Fire; Floor slab; Internal force; Membrane mechanism; Numerical simulation; Steel frame;
D O I
10.6052/j.issn.1000-4750.2020.07.0489
中图分类号
学科分类号
摘要
The influence of the position and quantity of fire span on the fire behavior of concrete floor in the structure is studied. Based on Vulcan software, using thick plate element and beam-column element, combined with EC2 material high temperature constitutive model, the temperature and deformation of fire top floor (corner and middle) and second floor (four) in a steel frame structure are simulated numerically. The influence of concrete expansion strain on the deformation of floor slab under fire is analyzed, and the membrane mechanism, crack distribution and internal force development of steel beam are investigated. The results show that: the predicted results of floor temperature and deformation are in a good agreement with the experimental results, and the concrete expansion strain has a decisive influence on the mid-span deformation of the fire zone in the structure, that is, when the expansion strain is larger, the predicted deformation is larger; the boundary conditions have a decisive influence on the membrane mechanism and crack distribution of the heated plate, and the heated plates have three kinds of membrane mechanisms: ring type, opposite-edge U type and diagonal U type. The bending moment and axial force of the steel beam near the heated grid gradually increase, and the increase of the axial force of the steel beam is relatively large. Copyright ©2021 Engineering Mechanics. All rights reserved.
引用
收藏
页码:133 / 146
页数:13
相关论文
共 30 条
  • [21] Ellobody E, Bailey C G., Structural performance of a post-tensioned concrete floor during horizontally traveling fires, Engineering Structures, 33, pp. 1908-1917, (2011)
  • [22] Gernay T, Khorasani N E., Recommendations for performance-based fire design of composite steel buildings using computational analysis, Journal of Constructional Steel Research, 166, (2020)
  • [23] Eurocode 2: Design of concrete structures, ENV 1992: Part 1-2: General rules structural fire design, (1999)
  • [24] ASCE: Structural fire protection, manual No. 78, ASCE committee on fire protection, structural division, (1992)
  • [25] Li Guoqiang, Zhou Haosheng, Guo Shixiong, Mechanism and theoretical model of membrane action in slabs of steel buildings subjected to fire, Journal of Building Structures, 28, 5, pp. 40-47, (2007)
  • [26] Liu Y, Huang S S, Burgess I., Performance of a novel ductile connection in steel-framed structures under fire conditions, Journal of Constructional Steel Research, 169, (2020)
  • [27] Qiao Changjiang, Fire resistance of reinforced concrete restrained members during heating and cooling phases, (2009)
  • [28] Wu Bo, Qiao Changjiang, Experimental study on fire behaviors of RC restrained beams during heating and cooling phases, Engineering Mechanics, 28, 6, pp. 88-95, (2011)
  • [29] Zhang Jianchun, Zhang Dashan, Dong Yuli, Et al., Experimental study on internal force variation of steel-concrete composite beam under fire, Engineering Mechanics, 36, 6, pp. 183-192, (2019)
  • [30] Rackauskaitea E, Kotsovinos P, Jeffers A, Et al., Computational analysis of thermal and structural failure criteria of a multi-storey steel frame exposed to fire, Engineering Structures, 180, pp. 524-543, (2019)