Treatment of selected distal radius fractures with nonbridging external fixation

被引:2
|
作者
Hajianpour M.A. [1 ]
Sheikh B. [1 ]
Feanny M. [1 ]
Berkowitz M. [1 ]
Latta L. [2 ]
机构
[1] Total Orthopaedic Care, Lauderdale Lakes, 33313, FL
[2] Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, 33136, FL
关键词
Colles; fractures; Distal radius fractures; External fixation;
D O I
10.1615/JLongTermEffMedImplants.2020036110
中图分类号
学科分类号
摘要
A nonbridging external fixation (NBX) system with 1.6-mm diameter pins provided excellent stability for distal radius fractures in cadavers. For the present study, all patients with distal radius fractures were seen by the surgeon authors. Fractures that were displaced and unstable, including Orthopaedic Trauma Association (OTA) types 23-A2.3 to C3.3, were reduced and fixed with the NBX system. The Western Institutional Review Board granted approval (296864) for this retrospective study. Fractures numbered five OTA-A2, eight OTA-A3, two OTA-B3, one OTA-C1, two OTA-C2, and eight OTA-C3. In total, the study included 26 patients. At fixator removal, average dorsiflexion was 37.0° ± 17.8°; volar flexion, 39.4° ± 17.2°; pronation, 80.6° ± 16.1°; and supination, 48.1° ± 24.2°. Follow-up averaged 11.7 mo ± 19.2 mo. At final follow-up, average dorsiflexion was 52.9° ± 25.0°; volar flexion, 53.1° ± 23.7°; pronation, 80.8° ± 14.5°; and supination, 67.7° ± 30.3°. Average radial tilt at the time of injury was 11.6° ± 8.3°; post op to 23.9° ± 5.0°; and at last follow-up, 23.1° ± 5.0°. Average radial styloid length at the time of injury was 4.1 mm ± 3.7 mm; post op to 11.4 mm ± 3.0 mm; and at last follow-up, 10.5 mm ± 3.1 mm. Volar tilt at the time of injury averaged –19.6° ± 14.8°; reduced to 9.8° ± 6.3°; and at last follow-up, 7.5° ± 6.5°. This form of nonbridging fixation is safe and effective at maintaining reduced, extra-and intra-articular, distal radius fractures and allows functional range of motion with minimal complications. © 2020 by Begell House.
引用
收藏
页码:199 / 204
页数:5
相关论文
共 50 条
  • [21] The Role of External Fixation in the Treatment of Unstable Distal Radius Fractures
    Pritt, Jonathan
    Rizzo, Marco
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2009, 19 (02) : 60 - 64
  • [22] OPERATIVE TREATMENT OF FRACTURES OF THE DISTAL RADIUS USING EXTERNAL FIXATION
    WAGNER, HE
    JAKOB, RP
    UNFALLCHIRURG, 1985, 88 (11): : 473 - 480
  • [23] External fixation, not ORIF, as the treatment of choice for fractures of the distal radius
    Weiland, AJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (08) : 570 - 572
  • [24] Bridging versus Nonbridging Dynamic External Fixation of Unstable Distal Radius Fractures in the Elderly with Polytrauma: A Randomized Study
    Aita, Marcio Aurelio
    Rodrigues, Fabio Lucas
    Crispim Ribeiro Alves, Karyse Helena
    de Oliveira, Ricardo Kaempf
    Ruggiero, Gustavo Mantovani
    Reis Rodrigues, Luciano Miller
    JOURNAL OF WRIST SURGERY, 2019, 8 (05) : 408 - 415
  • [25] Dynamic external fixation for distal radius fractures
    Dienst, M
    Wozasek, GE
    Seligson, D
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (338) : 160 - 171
  • [26] EXTERNAL FIXATION FOR INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS
    JAKIM, I
    PIETERSE, HS
    SWEET, MBE
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02): : 302 - 306
  • [27] DYNAMIC EXTERNAL FIXATION OF DISTAL RADIUS FRACTURES
    PENNIG, DW
    HAND CLINICS, 1993, 9 (04) : 587 - 602
  • [28] External fixation techniques for distal radius fractures
    Capo, John T.
    Swan, Kenneth G., Jr.
    Tan, Virak
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (445) : 30 - 41
  • [29] Comparative study of nonbridging and bridging external fixators for unstable distal radius fractures
    Uchikura, C
    Hirano, J
    Kudo, F
    Satomi, K
    Ohno, T
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (06) : 560 - 565
  • [30] Treatment of unstable distal radius fractures with cancellous allograft and external fixation
    Herrera, M
    Chapman, CB
    Roh, M
    Strauch, RJ
    Rosenwasser, MP
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1999, 24A (06): : 1269 - 1278