Design and optimisation of stand-alone hybrid energy system for rural areas

被引:0
|
作者
Raghuwanshi, Santosh S. [1 ]
Masih, Animesh [1 ]
Raghuwanshi, Prashant [1 ]
机构
[1] Electrical Engineering Department, Medi-Caps University, Indore, India
关键词
Battery - Battery energy - Design and optimization - Energy systems - Hybrid energy system - Modeling - Optimal energy - Optimisations - Stand -alone - Systems Configuration;
D O I
暂无
中图分类号
学科分类号
摘要
The main aim of this work is to design and select the optimal photovoltaic based energy system that can meet the rural area irrigation and domestic load demand. The selection of optimal energy system configuration is based on modelling, economic and reliability analysis. Soft optimisation computing tools (MATLAB & HOMER Pro) and Markov reliability methods are used to identify optimal energy system configuration. The results show that the COE of PV/battery is ≠6.87, PV/diesel/battery is ≠14.29, PV/DG is ≠30.25, DG/battery is ≠34.71 and DG is ≠36.12. Energy capacity shortage is higher in PV/battery (8%) and approx. zero in PV/DG/battery system. The reduction of fuel cost from diesel only system to hybrid PV/DG/battery energy system is 42.46%. PV/DG/battery failure rate (0.01101), EENS (0.080), and LOLP (0.00000725) are minimum as compared to another configuration. The obtained results conclude that a hybrid PV/DG/battery energy system is a cost-effective, sustainable and reliable system for rural areas in India. © 2022 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:8707 / 8721
相关论文
共 50 条
  • [41] Stand-alone Hybrid Renewable Energy System-An Alternative to Increased Energy Demand
    Tudu, B.
    Mandal, K. K.
    Chakraborty, N.
    Mukherjee, I.
    2014 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, ENERGY & COMMUNICATION (CIEC), 2014, : 335 - 339
  • [42] Multi Objective Design of Stand-alone PV/Wind Energy System by Using Hybrid GA and PSO
    Amereh, Mohammad
    Khozani, Zahra Shiravi
    Kazemi, Ahad
    2014 22ND IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2014, : 695 - 699
  • [43] Optimal Design of a Stand-Alone Residential Hybrid Microgrid System for Enhancing Renewable Energy Deployment in Japan
    Yoshida, Yuichiro
    Farzaneh, Hooman
    ENERGIES, 2020, 13 (07)
  • [44] Flexible Design and Assessment of a Stand-Alone Hybrid Renewable Energy System: A Case Study Marrakech, Morocco
    Ladide, Saad
    EL Fathi, Amine
    Bendaoud, Mohamed
    Hihi, Hicham
    Faitah, Khalid
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2019, 9 (04): : 2003 - 2022
  • [45] Dynamic Stability Enhancement of a Hybrid Renewable Energy System in Stand-Alone Applications
    Touti, Ezzeddine
    Zayed, Hossem
    Pusca, Remus
    Romary, Raphael
    COMPUTATION, 2021, 9 (02) : 1 - 10
  • [46] Analysis of a small wind-hydrogen stand-alone hybrid energy system
    Khan, M. J.
    Iqbal, M. T.
    APPLIED ENERGY, 2009, 86 (11) : 2429 - 2442
  • [47] Stand-alone PV system based on new structure of hybrid energy storage
    Zhang, Yingchao
    Long, Jiangtao
    Guo, Zhen
    Zhang, Yangjun
    Qian, Xisen
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2014, 35 (12): : 2461 - 2467
  • [48] Stand-alone wind power system with battery/supercapacitor hybrid energy storage
    Pan, Ting-Long
    Wan, Hong-Shu
    Ji, Zhi-Cheng
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENGINEERING, 2014, 7 (02) : 103 - 110
  • [49] Smart control and management for a renewable energy based stand-alone hybrid system
    Kechida, Abdelhak
    Gozim, Djamal
    Toual, Belgacem
    Alharthi, Mosleh M.
    Agajie, Takele Ferede
    Ghoneim, S. M. Sherif
    Ghaly, Ramy N. R.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [50] COMPARATIVE EVALUATION OF STAND-ALONE HYBRID POWER SYSTEM WITH DIFFERENT ENERGY STORAGES
    Ozturk, Zafer
    Tosun, Salih
    Ozturk, Ali
    Akar, Onur
    FRESENIUS ENVIRONMENTAL BULLETIN, 2021, 30 (09): : 10908 - 10924