Digital twin-driven energy consumption management of integrated heat pipe cooling system for a data center

被引:0
|
作者
Zhu, Haitao [1 ]
Lin, Botao [1 ]
机构
[1] China Univ Petr, Coll Informat Sci & Engn, Coll Artificial Intelligence, Beijing 102249, Peoples R China
关键词
Digital twin; Energy consumption management; Cooling system; Real-time interaction; Genetic algorithm; SIMULATION; PROGNOSTICS; EFFICIENCY; CFD;
D O I
10.1016/j.apenergy.2024.123840
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The energy consumption management (ECM) for the integrated heat pipe cooling (IHPC) systems has become a significant cost-cutting strategy, given the growing demand for the decreased cooling and maintenance costs in data centers. However, the traditional ECM strategies lack an integration with the real-time information and the automatic feedback control, causing the risks of system operation difficult to diagnose and the potential for energy saving hard to exploit. In this respect, a digital twin approach was proposed to efficiently and automatically implement the ECM strategy for an IHPC system. First, a digital twin architecture was established to enable seamless integration and real-time interaction between the physical system and the digital twin. Secondly, the digital twin models of monitoring, simulation, energy evaluation and optimization were developed to drive the corresponding services. Finally, the approach was verified on an IHPC system operating in a real-life data center. It is found that the approach can automatically detect and justify the abnormal states of the IHPC system. Moreover, the approach can reduce the power consumption by 23.63% while meeting the production requirements. The mean relative errors of the supply air temperature and the cooling capacity between the digital twin simulated and the on-site records are 1.43% and 1.46%, respectively. In summary, the proposed approach provides a digital twin workflow that can significantly improve the efficiency of the ECM strategy deployed on an IHPC system.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Digital twin-driven SDN for smart grid: A deep learning integrated blockchain for cybersecurity
    Kumar, Prabhat
    Kumar, Randhir
    Aljuhani, Ahamed
    Javeed, Danish
    Jolfaei, Alireza
    Islam, A. K. M. Najmul
    SOLAR ENERGY, 2023, 263
  • [32] Digital twin-driven energy modeling of Hywind Tampen floating wind farm
    Qaiser, Muhammad Talal
    Ejaz, Jasim
    Osen, Ottar
    Hasan, Agus
    ENERGY REPORTS, 2023, 9 : 284 - 289
  • [33] Digital twin-driven robotic arm operation simulation and health management research
    Li, Guofang
    Yang, Kang
    Dong, Zhiyu
    Ji, Xiaoli
    Wu, Shaopei
    INTERNATIONAL JOURNAL OF MODELING SIMULATION AND SCIENTIFIC COMPUTING, 2023, 14 (06)
  • [34] Digital Twin-Driven Approach for Process Management and Traceability towards Ship Industry
    Wang, Kan
    Hu, Qianqian
    Liu, Jialin
    PROCESSES, 2022, 10 (06)
  • [35] DATA CENTER ENERGY CONSERVATION BY HEAT PIPE COLD ENERGY STORAGE SYSTEM
    Wu, Xiao Ping
    Mochizuki, Masataka
    Mashiko, Koichi
    Thang Nguyen
    Tien Nguyen
    Wuttijumnong, Vijit
    Cabusao, Gerald
    Singh, Randeep
    Akbarzadeh, Aliakbar
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010 , VOL 3: COMBUSTION, CONDUCTION, ELECTRONIC COOLING, EVAPORATION,TWO-PHASE FLOW, 2010, : 701 - 709
  • [36] A digital twin-driven deformation monitoring system for deep foundation pit excavation
    Chen, K.
    Liu, Y.
    Hu, R.
    Fang, W.
    Proceedings of the 29th EG-ICE International Workshop on Intelligent Computing in Engineering, 2022, : 144 - 153
  • [37] Data center energy consumption simulator from the servers to their cooling system
    Tran Van Giang
    Debusschere, Vincent
    Bacha, Seddik
    2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [38] Digital Twin System of Pest Management Driven by Data and Model Fusion
    Dai, Min
    Shen, Yutian
    Li, Xiaoyin
    Liu, Jingjing
    Zhang, Shanwen
    Miao, Hong
    AGRICULTURE-BASEL, 2024, 14 (07):
  • [39] Digital twin-driven strategic demolition plan for circular asset management of bridge infrastructures
    Kaewunruen, Sakdirat
    O'Nell, Connor
    Sengsri, Pasakorn
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [40] DATA CENTER ENERGY CONSERVATION BY HEAT PIPE BASED PRECOOLER SYSTEM
    Singh, Randeep
    Mochizuki, Masataka
    Mashiko, Koichi
    Thang Nguyen
    FRONTIERS IN HEAT AND MASS TRANSFER, 2019, 13