PROPOSAL OF OPTIMAL COOPERATIVE CONTROL METHOD FOR AIR CONDITIONING INDOOR UNITS USING SPARSENESS

被引:0
|
作者
Nishijima Y. [1 ]
Shiraishi Y. [2 ]
Nagahara M. [3 ]
机构
[1] Faculty of Environmental Engineering, Univ. of Kitakyushu
[2] Faculty of Informatics and Data Science, Hiroshima University
来源
关键词
Air conditioning;
D O I
10.3130/AIJE.88.447
中图分类号
学科分类号
摘要
The advantage of multi-split packaged air-conditioning system is high operational flexibility and energy efficiency. However, since adjacent indoor units affect each other, the control becomes complex and can cause the deterioration of indoor thermal environment and the increase of energy consumption. Therefore, we propose the cooperative control method that combines MIMO MPC and sparse modeling, here referred to as Sparse MPC, and to verify the proposed method. The results confirmed that Sparse MPC reduces the air conditioning operating time and the number of units in operation. This suggests that Sparse MPC may improve the energy efficiency of air conditioning systems. © 2023 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:447 / 453
页数:6
相关论文
共 50 条
  • [31] Optimal control strategy for a multi-zone air conditioning system using a genetic algorithm
    Mossolly, M.
    Ghali, K.
    Ghaddar, N.
    ENERGY, 2009, 34 (01) : 58 - 66
  • [32] OPTIMAL INDOOR TEMPERATURE CONTROL USING A PREDICTOR
    LUTE, P
    VANPAASSEN, D
    IEEE CONTROL SYSTEMS MAGAZINE, 1995, 15 (04): : 4 - 10
  • [33] Frequency control of inverter air conditioning based on ESO nonlinear optimal control
    Kang Z.
    Li K.
    Chang Z.
    Li, Kaiji (1580157286@qq.com), 1600, Power System Protection and Control Press (48): : 91 - 98
  • [34] Research on a novel air conditioning system for improved indoor thermal environment control
    Yang, Liu
    Liu, Shengnan
    Li, Weilin
    Yan, Huaxia
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 41
  • [35] Simulation of the control effect to the indoor contamination by different air-conditioning mode
    Liu, J
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 404 - 407
  • [36] Study on indoor temperature optimal control of air-conditioning based on Twin Delayed Deep Deterministic policy gradient algorithm
    Li, Wei
    Wu, Hongji
    Zhao, Yifan
    Jiang, Changwei
    Zhang, Jili
    ENERGY AND BUILDINGS, 2024, 317
  • [37] The predictive control method of VAV air conditioning system
    Li, J. (814686683@qq.com), 1600, Universitas Ahmad Dahlan, Jalan Kapas 9, Semaki, Umbul Harjo,, Yogiakarta, 55165, Indonesia (11):
  • [38] Optimization Control Method of VAV Air Conditioning System
    Zhang, Xiaocheng
    Wang, Ronghao
    Xing, Jianchun
    PROCEEDINGS OF THE 2016 12TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2016, : 1105 - 1110
  • [39] An Optimal Hybrid Control Method for Energy-Saving of Chilled Water System in Central Air Conditioning
    Zhang, Yan
    Chu, Xiaoli
    Liu, Yongqiang
    JOURNAL OF CONTROL SCIENCE AND ENGINEERING, 2018, 2018
  • [40] An Air Conditioning Control Method Based on Biological Fluctuation
    Matsumoto, Hiroki
    Iwai, Yoshio
    Nakamura, Yutaka
    Ishiguro, Hiroshi
    DESIGN, USER EXPERIENCE, AND USABILITY: THEORY, METHODS, TOOLS AND PRACTICE, PT 2, 2011, 6770 : 608 - 615