Experimental study on the flow field and economic characteristics of parallel push-pull ventilation system

被引:5
|
作者
Wang Y. [1 ,2 ]
Quan M. [1 ,2 ]
Zhou Y. [1 ,2 ]
Cao Y. [1 ,2 ]
Xie C. [1 ,2 ]
Li L. [1 ,2 ]
机构
[1] State Key Laboratory of Green Building in Western China, Xi'an University of Architecture and Technology
[2] School of Building Services Science and Engineering, Xi'an University of Architecture and Technology, Xi'an
来源
Energy and Built Environment | 2020年 / 1卷 / 04期
关键词
Economic characteristics; Flow field; Parallel flow; Push-pull ventilation system;
D O I
10.1016/j.enbenv.2020.03.006
中图分类号
学科分类号
摘要
Push-pull ventilation systems provide excellent control of contaminants and harmful gases. However, since both a push inlet and a pull outlet are used in the push-pull ventilation system, the flow rate required by the system is large. In that case, the energy consumption of the system is large. The purpose of this paper is to study the flow field and economic characteristics of a parallel push-pull ventilation system by reducing the flow rate of the exhaust outlet, which will be achieved by reducing the size of the exhaust hood. The three commonly used push-pull ventilation systems were analyzed: a high velocity push-pull system with high air supply velocity, a low velocity push-pull system with wide airflow and small velocity, and a parallel push-pull system with wide airflow and uniform air supply velocity. Results showed that the parallel push-pull ventilation system was the only one in which the flow rate of the exhaust outlet could be reduced, reducing the overall energy consumption. Under conditions of the parallel air supply jet, the diffusion range of contaminants in the push-pull flow field was the smallest and reducing the exhaust air flow rate did not affect the capture efficiency of pollutants. These results may be useful in guiding the design of push-pull ventilation system and optimize economic constraints. © 2020
引用
收藏
页码:393 / 403
页数:10
相关论文
共 50 条
  • [41] Enhanced Aneurysmal Flow Diversion Using a Dynamic Push-Pull Technique: An Experimental and Modeling Study
    Ma, D.
    Xiang, J.
    Choi, H.
    Dumont, T. M.
    Natarajan, S. K.
    Siddiqui, A. H.
    Meng, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (09) : 1779 - 1785
  • [42] Storage characteristics of push-pull azobenzene compound
    Jilin Univ, Changchun, China
    Guangxue Xuebao, 10 (1394-1398):
  • [43] A Push-Pull Parallel Resonant Converter-Based Bidirectional IPT System
    Zhao, Lei
    Thrimawithana, Duleepa J.
    Madawala, Udaya Kumara
    Hu, Aiguo Patrick
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (03) : 2659 - 2667
  • [44] CRYSTALLOGRAPHIC STUDY OF PUSH-PULL ETHYLENES
    ADHIKESAVALU, D
    KAMATH, NU
    VENKATESAN, K
    PROCEEDINGS OF THE INDIAN ACADEMY OF SCIENCES-CHEMICAL SCIENCES, 1983, 92 (4-5): : 449 - 456
  • [45] External characteristics model of push-pull transformer
    Wu, Jiaju
    Liu, Guiying
    Chen, Qiong
    Sugimoto, Hidehiko
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2011, 26 (03): : 123 - 128
  • [46] STUDY OF A PUSH-PULL PARAMETRIC TRANSFORMER
    ICHINOKURA, O
    TAJIMA, K
    JINZENJI, T
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (05) : 2181 - 2183
  • [47] Single-well push-pull test in transient Forchheimer flow field
    Wang, Quanrong
    Zhan, Hongbin
    Wang, Yanxin
    JOURNAL OF HYDROLOGY, 2017, 549 : 125 - 132
  • [48] Push-pull ventilation in a painting shop for large steel constructions
    Svidt, K
    Heiselberg, P
    PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 37 - 40
  • [49] Using Metaheuristic and Fuzzy System for the Optimization of Material Pull in a Push-Pull Flow Logistics Network
    Mehrsai, Afshin
    Karimi, Hamid-Reza
    Thoben, Klaus-Dieter
    Scholz-Reiter, Bernd
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2013, 2013
  • [50] Modified push-pull ventilation for energy efficiency in process design
    Bomboy, KD
    PLATING AND SURFACE FINISHING, 1996, 83 (09): : 44 - 45