Dual-energy CT Portal Venography: Clinical Application Values and Future Opportunities

被引:0
|
作者
Peng, Yu Yang [1 ]
Yan, Jing [1 ]
Li, Yu Ru [1 ]
Lu, Xiao Rui [1 ]
Wang, Lu Yao [1 ]
Jia, Ping Fan [1 ]
Guo, Xing [1 ]
机构
[1] Changzhi Med Coll Affiliated Heping Hosp, Dept Med Imaging, Changzhi 046000, Shanxi, Peoples R China
关键词
Dual-energy CT; Portal venography; Contrast; Radiation dose; Iterative reconstruction; X-ray tube; CONCENTRATION CONTRAST-MEDIUM; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; ABDOMINAL CT; GADOPENTETATE DIMEGLUMINE; VEIN THROMBOSIS; ANGIOGRAPHY; PROTOCOL; ABDOMEN;
D O I
10.2174/0115734056248152231205045231
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Standard multidetector computed tomography (MDCT) uses a single X-ray tube to emit a mixed energy X-ray beam, which is received by a single detector. The difference is that dual-energy CT (DECT), a new equipment in recent years, employs a single X-ray tube or two X-ray tubes to emit two single-energy X-ray beams, which are received by a single or two detectors. The application of dual-energy technology to portal venography has become one of the research hotspots. This paper will elaborate on the clinical application values of DECT portal venography in improving portal vein image quality, distinguishing the nature of portal vein thrombus, reducing contrast agent dose and radiation dose, and will discuss the possibility of its movement from research to routine practice and future development opportunities.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Dual-energy CT revisited with multidetector CT: review of principles and clinical applications
    Karcaaltincaba, Musturay
    Aktas, Aykut
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (03): : 181 - 194
  • [42] Abdominal dual-source dual-energy CT: Uses in clinical practice
    Siegel, Marilyn J.
    Ramirez-Giraldo, Juan Carlos
    Graser, Anno
    APPLIED RADIOLOGY, 2013, 42 (11) : 10 - 16
  • [43] Dual-Energy CT for Diagnostic CT Colonography
    Karcaaltincaba, Musturay
    Ozdeniz, Ilknur
    RADIOGRAPHICS, 2014, 34 (03) : 847 - 847
  • [44] Clinical value of dual-energy spectral imaging with adaptive statistical iterative reconstruction for reducing contrast medium dose in CT portal venography: in comparison with standard 120-kVp imaging protocol
    Ma, Chun-Ling
    Chen, Xiao-Xia
    Lei, Yu-Xin
    Zhang, Xi-Rong
    Jia, Yong-Jun
    Tian, Xin
    Tian, Qian
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062):
  • [45] Potential Application of Dual-Energy CT in Gynecologic Cancer: Initial Experience
    Benveniste, Ana Paula
    Faria, Silvana de Castro
    Broering, Gregory
    Ganeshan, Dhakshina Moorthy
    Tamm, Eric P.
    Iyer, Revathy B.
    Bhosale, Priya
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) : 695 - +
  • [46] Dual-Energy CT and Spot Sign
    Vargas, M. I.
    Lovblad, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (10) : E63 - E63
  • [47] Dual-Energy CT of Intrahepatic Splenosis
    Zhang, Hui-Hui
    Tan, Xian-Zheng
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (06)
  • [48] Dual-Energy CT and Radiation Dose
    Reher, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (01) : 95 - 96
  • [49] Renal applications of dual-energy CT
    Kaza, Ravi K.
    Platt, Joel F.
    ABDOMINAL RADIOLOGY, 2016, 41 (06) : 1122 - 1132
  • [50] Dual-Energy CT of Gallstone Ileus
    Liu, Peng
    Tan, Xian-zheng
    RADIOLOGY, 2020, 295 (03) : 516 - 516