Stockbridge dampers for extending the fatigue life of a cable at St Nazaire cable stayed bridge

被引:0
|
作者
Berthellemy, Jacques [1 ]
Siegert, Dominique [2 ]
Berton, Édouard [3 ]
Quentin, Pierre [4 ]
机构
[1] Steel Bridges Engineering Expert at Cerema, France
[2] COSYS/IMSE, University Gustave Eiffel, France
[3] Engineer at Cerema, France
[4] Engineer at Loire-Atlantique Local Authority, France
关键词
Anchorages (foundations) - Bridge cables - Buffeting - Cable stayed bridges - Vortex flow;
D O I
暂无
中图分类号
学科分类号
摘要
The failure of a stay cable on the Saint-Nazaire bridge is investigated in detail. In 2000, fatigue cracks that had cut many wires led to a first replacement, alike to the initial, of the H32 stay cable. Examination of the deposited locked coil strand showed that fretting fatigue was involved in the wire breaks. The cause of the failures at the anchorages is discussed/studied in depth in the paper. Bending moments of the rigid cable, at its exit from the anchorage socket were proven to be the source of the fatigue stress due to vibrations induced by vortex detachments (VIV: Vortex Induced Vibrations). As wires ruptures occurred again in 2017 in the new H32 stay cable at the same place, further studies on dampers were carried out. After numerical simulations, the Stockbridge damper became a good candidate for attenuating the amplitude of vibrations. It could indeed be designed to fit the required frequency range between 30 and 35 Hz. © 2022
引用
收藏
相关论文
共 50 条
  • [21] Uddevalla cable-stayed bridge
    Hansvold, C
    Lundh, L
    Larsson, KE
    Nilsson, H
    STRAIT CROSSINGS 2001, 2001, : 27 - 33
  • [22] Control of seismically excited cable-stayed bridge employing magnetorheological fluid dampers
    Jung, HJ
    Spencer, BF
    Lee, IW
    JOURNAL OF STRUCTURAL ENGINEERING, 2003, 129 (07) : 873 - 883
  • [23] Seismic response control of a cable-stayed bridge using negative stiffness dampers
    Li, Hui
    Liu, Jinlong
    Ou, Jinping
    STRUCTURAL CONTROL & HEALTH MONITORING, 2011, 18 (03): : 265 - 288
  • [24] Mathematical Modeling of Cable - Stayed Bridge
    Mao, Yuanfu
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON EDUCATION, MANAGEMENT, INFORMATION AND MECHANICAL ENGINEERING (EMIM 2017), 2017, 76 : 1816 - 1820
  • [25] The Millau cable-stayed bridge
    Virlogeux, M
    RECENT DEVELOPMENTS IN BRIDGE ENGINEERING, 2003, : 3 - 18
  • [26] Innovative cable-stayed bridge
    Christoffersen, Jens
    Jensen, Henrik Elgaard
    Hauge, Lars
    Bjerrum, John
    Concrete (London), 1998, 32 (07): : 32 - 34
  • [27] The colletta cable-stayed bridge
    Petrangeli, Mario Paolo
    Industria Italiana del Cemento, 2006, 76 (823): : 728 - 743
  • [28] Cable-stayed pedestrian bridge
    Fernandez, P
    PCI JOURNAL, 2000, 45 (04): : 119 - 119
  • [29] Flutter analysis of cable stayed bridge
    Sukamta
    Guntorojati, Ireng
    Fariduzzaman
    3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS - SUSTAINABLE STRUCTURES FOR FUTURE GENERATIONS, 2017, 171 : 1173 - 1177
  • [30] Influence of Fatigue on Cable Arrangement in Cable-stayed Bridges
    Pipinato, A.
    Pellegrino, C.
    Fregno, G.
    Modena, C.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2012, 12 (01) : 107 - 123