Design and Analysis of 10kW High-frequency Planar Transformer for Arc Welding Machine

被引:0
|
作者
Yoo J.-G. [1 ]
Kim J.-S. [1 ]
机构
[1] Department of Energy Engineering, Daejin University
关键词
Arc welding machine; efficiency; High frequency dc-dc converter; Planar transformer; Power density;
D O I
10.5370/KIEE.2022.71.12.1780
中图分类号
学科分类号
摘要
In this paper, a design method for a 10kW planar transformer is presented. The problems and design considerations when applying a planar transformer to a 10kW arc welder are described. We present a design technique considering power density, heat generation, and efficiency, which are important elements of a planar transformer. In addition, in order to verify the validity of the design, general winding transformers, winding type planar transformers, and printed circuit board type planar transformers are designed, respectively, and finite element method (FEM) simulations and experiments are performed for efficiency and heat generation. As a result of the experiment based on the proposed planar transformer, it is confirmed that the rated system efficiency is improved by 2.1%, the power density by 204%, and the transformer temperature by 28.3℃ compared to the normal winding transformer designed under the same conditions. Copyright © The Korean Institute of Electrical Engineers.
引用
收藏
页码:1780 / 1786
页数:6
相关论文
共 50 条
  • [21] Analysis of favored design frequency of high-frequency transformer with different power capacities
    Liu Keke
    Li Lin
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [22] A High-Frequency Planar Transformer with Medium-Voltage Isolation
    Mukherjee, Satyaki
    Majmunovic, Branko
    Seo, Gab-Su
    Dutta, Soham
    Mallik, Rahul
    Johnson, Brian
    Maksimovic, Dragan
    2021 THIRTY-SIXTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2021), 2021, : 2065 - 2070
  • [23] HIGH-FREQUENCY REVERSING ARC SWITCH FOR PLASMA ARC WELDING OF ALUMINUM.
    Kyselica, S.
    Welding Journal (Miami, Fla), 1987, 66 (0l): : 31 - 35
  • [24] HIGH-FREQUENCY REVERSING ARC SWITCH FOR PLASMA-ARC WELDING OF ALUMINUM
    KYSELICA, S
    WELDING JOURNAL, 1987, 66 (01) : 31 - 35
  • [25] Magnetic flux leakage analysis and compensation of high-frequency planar insulated core transformer
    田佳甲
    刘永好
    李瑞
    李德明
    卢宋林
    NuclearScienceandTechniques, 2015, 26 (03) : 23 - 27
  • [26] Magnetic flux leakage analysis and compensation of high-frequency planar insulated core transformer
    Tian Jia-Jia
    Liu Yong-Hao
    Li Rui
    Li De-Ming
    Lu Song-Lin
    NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (03)
  • [27] A Study on the Transformer Design considering the Inrush Current Reduction in the Arc Welding Machine
    Kim, In-Gun
    Liu, Huai-Cong
    Cho, Su-Yeon
    Lee, Ju
    JOURNAL OF MAGNETICS, 2016, 21 (03) : 374 - 378
  • [28] Insulation Design on High-Frequency Transformer for Solid-State Transformer
    Li, Zheqing
    Hsieh, Yi-Hsun
    Li, Qiang
    Lee, Fred C.
    Zhao, Chunyang
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 1149 - 1155
  • [29] Optimum design of a high-power, high-frequency transformer
    Petkov, R
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1996, 11 (01) : 33 - 42
  • [30] High-Frequency Current Transformer Design and Construction Guide
    Fritsch, Martin
    Wolter, Martin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71