PROTECTED INSULATED WIRES FOR MEDIUM-VOLTAGE OVERHEAD POWER LINES: ADVANTAGES, COMPUTATIONS

被引:0
|
作者
Podoltsev O.D. [1 ]
Kucheriava I.M. [1 ]
机构
[1] Institute of Electrodynamics National Academy of Sciences of Ukraine, pr. Peremohy,56, Kyiv
来源
Technical Electrodynamics | 2022年 / 2022卷 / 05期
关键词
Computer modeling; Current density; High frequency; Medium voltage; Overhead power lines; Polyethylene insulation; Protected insulated wires; Resistance; Self-supporting insulated wires; Steel core;
D O I
10.15407/techned2022.05.014
中图分类号
TG [金属学与金属工艺];
学科分类号
0805 ;
摘要
The paper presents the advantages of protected insulated wires for medium-voltage (up to 35 kV) overhead power lines compared to the lines with traditional non-insulated wires. The mathematical model is developed and the computer calculations are realized for a 20 kV protected insulated wire with a steel-aluminum core. For such design, the distributions of the magnetic field and current density in three wires of overhead power line are analyzed, their resistance is determined taking into account the nonlinear properties of the steel core within the frequency range of 50–10000 Hz. This makes it possible to compute the electrical losses in the conductors of the power lines under the transient conditions and at high harmonics in the power network. References 8, figures 4 © 2022. Technical Electrodynamics.All Rights Reserved.
引用
收藏
页码:14 / 17
页数:3
相关论文
共 50 条
  • [41] MEDIUM-VOLTAGE CONTROLLERS SHOW ADVANTAGES OVER CIRCUIT-BREAKERS
    VYAS, NM
    BRAUER, RC
    POWER ENGINEERING, 1981, 85 (06) : 82 - 85
  • [42] MEDIUM-VOLTAGE CONTROLLERS SHOW ADVANTAGES OVER CIRCUIT BREAKERS.
    Vyas, Niren M.
    Brauer, Robert C.
    Power Engineering (Barrington, Illinois), 1981, 85 (06): : 82 - 85
  • [43] Comparative analysis of indicators and reliability properties of medium voltage overhead and cable power lines
    Chojnacki, Andrzej L.
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (11): : 26 - 30
  • [44] Influence of the presence of grounded wires on the lightning performance of a medium-voltage line
    Tossani, F.
    Napolitano, F.
    Borghetti, A.
    Nucci, C. A.
    Piantini, A.
    Kim, Yun-Su
    Choi, Sun-Kyu
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 196
  • [45] Insulated power supply for gate drivers up to 40kV for medium-voltage direct current applications
    Sarrazin, Benoit
    Hanna, Rachelle
    Lefranc, Pierre
    Am, Sokchea
    Dumas, Florian
    Lavieville, Jean-Paul
    IET POWER ELECTRONICS, 2017, 10 (15) : 2143 - 2148
  • [46] Auxiliary Power Supply for Medium-voltage Power Electronics Systems
    Won, Jehyuk
    Jalali, Gholamreza
    Liang, Xinyu
    Zhang, Chi
    Srdic, Srdjan
    Lukic, Srdjan
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 173 - 179
  • [47] GAS-INSULATED, MEDIUM-VOLTAGE SWITCH DISCONNECTOR PACKAGES FOR TRANSFORMER SUBSTATIONS
    MULLER, GCJ
    BROWN BOVERI REVIEW, 1985, 72 (12): : 586 - 591
  • [48] Using radio frequency and ultrasonic antennas for inspecting pin-type insulators on medium-voltage overhead distribution lines
    Lefort, C.
    Martinez, M.
    INGENIERIA E INVESTIGACION, 2013, 33 (02): : 63 - 69
  • [49] Defeat of overhead lines transmission networks with protected wires from lightning strike
    Sergey, Shevchenko
    Dmitriy, Danilchenko
    2015 INTERNATIONAL YOUNG SCIENTISTS FORUM ON APPLIED PHYSICS (YSF), 2015,
  • [50] Application of additional grounded wires in high voltage overhead power lines to reduce the intensity of electric field generated by phase wires
    Gumiela, Jacek
    Sztafrowski, Dariusz
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (03): : 159 - 161