Study on Voltage Drop, Transformer Capacity and Impedance during Induction Motor Starting

被引:0
|
作者
Kim J.-G. [1 ]
机构
[1] Dept. of Electrical Engineering, Gangneung-wonju National University
关键词
Induction motor; Percent impedance; Starting current; Transformer; Voltage drop;
D O I
10.5370/KIEE.2022.71.4.669
中图分类号
学科分类号
摘要
Induction motors have the disadvantage of generating a voltage drop due to a high current during startup. This voltage drop may have a bad effect on other loads, so the voltage drop must be reduced within a certain range. The improvement of the starting method is also important to reduce the voltage drop, but the contents of the transformer's capacity and percent impedance are also very important. Transformers have different percent impedance depending on their capacity and voltage. The percent impedance is also related to the voltage drop. The higher the capacity of the transformer, the higher the percent impedance, and the lower the capacity, the lower the percent impedance. In this study, in order to limit the voltage drop to within the allowable range when starting the induction motor directly, the transformer capacity was calculated by considering the percent impedance together. ©The Korean Institute of Electrical Engineers
引用
收藏
页码:669 / 674
页数:5
相关论文
共 50 条
  • [21] Investigation on Transformer Oil Impedance during Breakdown under Impulse Voltage
    Abdi, S.
    Boubakeur, A.
    Haddad, A.
    Harid, N.
    2014 ELECTRICAL INSULATION CONFERENCE (EIC), 2014, : 5 - 9
  • [22] MONEY-SAVING SOLUTIONS TO LOW VOLTAGE DURING MOTOR STARTING
    BELLINGE.TF
    WRIGHT, HA
    RUBBER AGE, 1968, 100 (09): : 62 - &
  • [23] A study on transient recovery voltage for transformer limited fault with large capacity transformer
    Kajino, Hiroki
    Ito, Hiroki
    Maegawa, Toshihiro
    Kamei, Kenji
    Idemaru, Toshiki
    Shinkai, Hiromu
    IEEJ Transactions on Power and Energy, 2013, 133 (05) : 473 - 479
  • [24] Exponential Impedance-Transformer Stalks Used for Magnetically Insulated Induction Voltage Adders
    Hu, Yixiang
    Sun, Fengju
    Zeng, Jiangtao
    Qiu, Ai'ci
    Wei, Hao
    Yin, Jiahui
    Cong, Peitian
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (11) : 3598 - 3602
  • [25] Study on the voltage stability of induction motor load
    Liu, P
    2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, 2004, : 295 - 298
  • [26] DIRECT ON LINE STARTING INDUCTION MOTOR WITH THYRISTOR SWITCHED CAPACITOR BASED VOLTAGE REGULATION
    da Silveira, Eben-ezer Prates
    Pires, Robson Celso
    Lyrio de Almeida, Antonio Tadeu
    Junqueira Rezek, Angelo Jose
    2009 BRAZILIAN POWER ELECTRONICS CONFERENCE, VOLS 1 AND 2, 2009, : 417 - 422
  • [27] Adjustable Frequency Single Phase Induction Motor Driver for Low Supply Voltage Starting
    Kabir, Shariar
    Ferdous, Md. Jannatul
    Azam, Md. Ali
    2013 INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION (ICIEV), 2013,
  • [28] Energy Saving during Induction Motor Starting under Loaded Conditions
    Hasanah, Rini Nur
    Nurwati, Tri
    Ardhenta, Lunde
    Suyono, Hadi
    Muljadi, Eduard
    2023 IEEE GREEN TECHNOLOGIES CONFERENCE, GREENTECH, 2023, : 112 - 117
  • [29] A MICROPROCESSOR-BASED FULL VOLTAGE STARTING OF INDUCTION-MOTOR WITH SWITCHED CAPACITORS
    SUBRAMANIAN, R
    CHELLAMUTHU, C
    ELECTRIC MACHINES AND POWER SYSTEMS, 1992, 20 (04): : 389 - 403
  • [30] DVR to Voltage Sag Mitigation Due to Induction Motor Starting and 3 Phase Fault
    Kuncoro, M.
    Garniwa, Iwa
    2018 5TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, COMPUTER, AND ELECTRICAL ENGINEERING (ICITACEE), 2018, : 73 - 78