Establishment of Diagnostic Reference Levels and Evaluation of Radiation Dose in Double Phase Abdominopelvic Computed Tomography

被引:0
|
作者
Keshtkar M. [1 ]
机构
[1] Medical Physics and Radiology Department, Faculty of Medicine, Infectious Diseases Research Center, Gonabad University of Medical Sciences, Gonabad
关键词
Abdomen; Computed Tomography; Effective Dose; Justification; Pelvis;
D O I
10.22038/IJMP.2022.64450.2105
中图分类号
学科分类号
摘要
Introduction: The purpose of this study was to establish of diagnostic reference level (DRL) and to compare radiation dose between single phase and unjustified double phase abdominopelvic CT imaging. Material and Methods: A total of 163 patients, 85 patients with single phase and 78 patients with unjustified double phase abdominopelvic CT scans, were included in this retrospective study. Volumetric CT dose index (CTDIvol) and dose length product (DLP) were obtained from the CT console. The third quartile of CTDIvol and DLP were determined for diagnostic reference level (DRL). Effective dose (E) and organ dose were obtained using CT-Expo software (version 2.2). Single phase and double phase scans were compared in terms of CTDIvol, DLP, size-specific dose estimate (SSDE), E and organ doses. Results: The institutional DRLs using CTDIvol and DLP for abdominopelvic CT were 9.8 mGy and 571 mGy.cm, respectively. The mean value of E was 5.4 ± 1.8 and 10.3 ± 3.4 for single phase and double phase imaging, respectively, resulting in 4.9 mSv excess dose per patient. Mean value of the DLP was 396.9 ± 142.7 and 759.0 ± 250.7 for single phase and double phase imaging, respectively. E was significantly higher in female compared to male (p < 0.05). Bladder has a highest lifetime attributed risk of cancer incidence among other organs. Also, the cancer risk incidence was higher for female than male. Conclusion: The awareness of physicians about the correct indications of abdominopelvic CT should be increased by using associated reliable guidelines. © 2023.
引用
收藏
页码:80 / 86
页数:6
相关论文
共 50 条
  • [21] Establishment of diagnostic reference levels and estimation of effective dose from computed tomography head scans at a tertiary hospital in South Africa
    Nyathi M.
    Iranian Journal of Medical Physics, 2020, 17 (02) : 99 - 106
  • [22] Establishment of local diagnostic reference levels for computed tomography with cloud-based automated dose-tracking software in Turkiye
    Kahraman, Gokhan
    Haberal, Kemal Murat
    Agildere, Ahmet Muhtesem
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (03): : 205 - 211
  • [23] Patient effective dose and radiation biological risk in the chest and abdominopelvic computed tomography
    Jamshidi, Mohammad Hossein
    Karami, Aida
    Salimi, Yazdan
    Keshavarz, Amirhesam
    APPLIED RADIATION AND ISOTOPES, 2023, 193
  • [24] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Najafi, Mohsen
    Deevband, Mohammad Reza
    Ahmadi, Mohsen
    Kardan, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 603 - 609
  • [25] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Mohsen Najafi
    Mohammad Reza Deevband
    Mohsen Ahmadi
    Mohammad Reza Kardan
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 603 - 609
  • [26] Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
    Abuzaid, Mohamed M.
    Elshami, Wiam
    Jayachandran, Deepa
    Korappil, Noushad
    Tekin, Huseyin O.
    TOMOGRAPHY, 2022, 8 (06) : 2939 - 2945
  • [27] Establishment of institutional Diagnostic Reference Levels for Computed Tomography examination at the University of Ghana Medical Centre
    Issahaku, Shirazu
    Amoh, Simon Mensah
    Acquah, Isaac Kwesi
    Nunoo, George
    Sackey, Theophilus A.
    HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1199 - 1207
  • [28] Establishment of institutional diagnostic reference level for Computed Tomography dose on 160 slicer Computed Tomography scan at Lady Reading Hospital Peshawar
    Khan, Muhammad Imran
    Khan, Muhammad Zeeshan
    Afzal, Fariha
    Zenab
    Khan, Shandana
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2023, 73 (04) : 808 - 811
  • [29] Radiation safety concerns and diagnostic reference levels for computed tomography scanners in Tamil Nadu
    Livingstone, Roshan S.
    Dinakaran, Paul M.
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (01) : 40 - 45
  • [30] Systematic Review on Diagnostic Reference Levels for Computed Tomography Examinations in Radiation Therapy Planning
    Rao, Shreekripa
    Sharan, Krishna
    Sukumar, Suresh
    Chandraguthi, Srinidhi Gururajarao
    Nisha Dsouza, Rechal
    David, Leena R.
    Ravichandran, Sneha
    Uzun, Berna
    Kadavigere, Rajagopal
    Uzun Ozsahin, Dilber
    DIAGNOSTICS, 2023, 13 (06)