Design of V-shaped cantilevers for enhanced multifrequency AFM measurements

被引:0
|
作者
Damircheli M. [1 ,2 ]
Eslami B. [1 ]
机构
[1] Department of Mechanical Engineering, Widener University, Chester, 19013, PA
[2] Department of Mechanical Engineering, Shahr-e-Qods Branch, Islamic Azad University, Tehran
关键词
bimodal AFM; optimization; soft matter; surface characterization; V-shaped cantilevers;
D O I
10.3762/BJNANO.11.135
中图分类号
学科分类号
摘要
As the application of atomic force microscopy (AFM) in soft matter characterization has expanded, the use of different types of cantilevers for these studies have also increased. One of the most common types of cantilevers used in soft matter imaging is V-shaped cantilevers due to their low normal spring constant. These types of cantilevers are also suitable for nanomanipulation due to their high lateral spring constants. The combination of low normal spring constant and high lateral spring constants makes V-shaped cantilevers promising candidates for imaging soft matter. Although these cantilevers are widely used in the field, there are no studies on the static and dynamic behavior of V-shaped cantilevers in multifrequency AFM due to their complex geometry. In this work, the static and dynamic properties of V-shaped cantilevers are studied while investigating their performance in multifrequency AFM (specifically bimodal AFM). By modeling the cantilevers based on Timoshenko beam theory, the geometrical dimensions such as length, base width, leg width and thickness are studied. By finding the static properties (mass, spring constants) and dynamic properties (resonance frequencies and quality factors) for different geometrical dimensions, the optimum V-shaped cantilever that can provide the maximum phase contrast in bimodal AFM between gold (Au) and polystyrene (PS) is found. Based on this study, it is found that as the length of the cantilever increases the 2nd eigenmode phase contrast decreases. However, the base width exhibits the opposite relationship. It is also found that the leg width does not have a monotone relationship similar to length and base width. The phase contrast increases for the range of 14 to 32 μm but decreases afterwards. The thickness of a V-shaped cantilever does not play a major role in defining the dynamics of the cantilever compared to other parameters. This work shows that in order to maximize the phase contrast, the ratio of second to first eigenmode frequencies should be minimized and be close to a whole number. Additionally, since V-shaped cantilevers are mostly used for soft matter imaging, lower frequency ratios dictate lower spring constant ratios, which can be advantageous due to lower forces applied to the surface by the tip given a sufficiently high first eigenmode frequency. Finally, two commercially available V-shaped cantilevers are theoretically and experimentally benchmarked with an optimum rectangular cantilever. Two sets of bimodal AFM experiments are carried out on Au-PS and PS-LDPE (polystyrene and low-density polyethylene) samples to verify the simulation results. © 2020 © 2020 Damircheli and Eslami; licensee Beilstein-Institut.
引用
收藏
页码:1525 / 1541
页数:16
相关论文
共 50 条
  • [31] V-Shaped Multislit Weirs
    Ramamurthy, A. S.
    Kai, J.
    Han, S. S.
    JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2013, 139 (07) : 582 - 585
  • [32] An optimization framework for the design of piezoelectric AFM cantilevers
    Moore, Steven Ian
    Ruppert, Michael G.
    Yong, Yuen Kuan
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2019, 60 : 130 - 142
  • [33] OPTIMIZATION OF FIRST MODE SENSITIVITY OF V-SHAPED AFM CANTILEVER USING GENETIC ALGORITHM METHOD
    Moeini, S. A.
    Kahrobaiyan, M. H.
    Rahaeifard, M.
    Ahmadian, M. T.
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 12, PTS A AND B, 2010, : 495 - 501
  • [34] Noncoplanar v-shaped antenna
    Zhengwei Du
    Chengli Ruan
    International Journal of Infrared and Millimeter Waves, 1997, 18 : 865 - 874
  • [35] V-SHAPED PREDENS SPACE
    BOHRER, SP
    KLEIN, A
    MARTIN, W
    SKELETAL RADIOLOGY, 1985, 14 (02) : 111 - 116
  • [36] V-SHAPED RADIAL LENS
    BARANOVA, LA
    NARYLKOV, SG
    YAVOR, SY
    ZHURNAL TEKHNICHESKOI FIZIKI, 1984, 54 (11): : 2245 - 2248
  • [37] Noncoplanar V-shaped antenna
    Univ of Electronic Science and, Technology of China, Sichuan, China
    Int J Infrared Millim Waves, 4 (865-874):
  • [38] Modeling and simulation of critical force and time in 3D manipulations using rectangular, V-shaped and dagger-shaped cantilevers
    Korayem, M. H.
    Hoshiar, A. K.
    Badrlou, S.
    Yoon, J.
    EUROPEAN JOURNAL OF MECHANICS A-SOLIDS, 2016, 59 : 333 - 343
  • [39] Finite element analysis of V-shaped cantilevers for atomic force microscopy under normal and lateral force loads
    Mueller, Matthias
    Schimmel, Thomas
    Haeussler, Pascal
    Fettig, Heiko
    Mueller, Ottmar
    Albers, Albert
    SURFACE AND INTERFACE ANALYSIS, 2006, 38 (06) : 1090 - 1095
  • [40] The stochastic dynamics of rectangular and V-shaped atomic force microscope cantilevers in a viscous fluid and near a solid boundary
    Clark, M.T.
    Paul, M.R.
    Journal of Applied Physics, 2008, 103 (09):