STUDIES ON COOLING OPERATION OF TABS COMBINED WITH FLOOR SUPPLY DISPLACEMENT AIR CONDITIONING SYSTEM

被引:0
|
作者
Akihiro K. [1 ]
Shinichiro O. [2 ]
Hisashi H. [3 ]
Masato N. [2 ]
Masayoshi Y. [2 ]
机构
[1] Institute of Technology, Shimizu Corporation
[2] Design Dept., Shimizu Corporation
[3] Group Leader, Institute of Technology, Shimizu Corporation, Dr.Eng.
关键词
Field survey; Floor supply; Load leveling; TABS; Water thermal storage tank;
D O I
10.3130/aijt.30.832
中图分类号
学科分类号
摘要
The cooling operational performance of TABS combined with floor supply displacement air conditioning system adopted in the Tohoku Branch of S company was investigated. The purpose of this research was to evaluate four control methods and clarify their energy consumption efficiency and load leveling effects. By operating with the proposed control method, the peak amount of received power was reduced by approximately 10%, confirming high energy consumption efficiency. Additionally, a thermal environment was created in the office as planned, with small temperature differences. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:832 / 837
页数:5
相关论文
共 50 条
  • [21] Status of air conditioning system operation in offices
    Zhang, Lei
    Li, Jisheng
    Zhao, Qingzhu
    Nuantong Kongtiao/HV & AC, 2000, 30 (06): : 12 - 15
  • [22] Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics
    Sekhar, SC
    Ching, CS
    ENERGY AND BUILDINGS, 2002, 34 (05) : 431 - 444
  • [23] SIMULATION OF COOLING AND HEATING LOADS UNDER INTERMITTENT OPERATION OF AIR CONDITIONING
    KIMURA, K
    ASHRAE JOURNAL, 1971, 13 (12): : 30 - &
  • [24] Experimental study including subjective evaluations of mixing and displacement ventilation combined with radiant floor heating/cooling system
    Krajcik, Michal
    Tomasi, Roberta
    Simone, Angela
    Olesen, Bjarne W.
    HVAC&R RESEARCH, 2013, 19 (08): : 1063 - 1072
  • [25] Integrated motor cooling and desiccant cooling for bus air conditioning system
    Chen, Peilin
    Zhang, Xu
    Nuantong Kongtiao/HV & AC, 2002, 32 (04):
  • [26] THE OPTIMIZED OPERATION STRATEGY OF CENTRALIZED WATER-COOLING AIR CONDITIONING SYSTEM IN MULTI-TERMINAL DATA CENTER BASED ON SUPPLY AND DEMAND MATCHING
    Ge, Yuyao
    Tu, Rang
    PROCEEDINGS OF ASME 2024 18TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, ES2024, 2024,
  • [27] Analysis of the Under-Floor Air Supply System
    He, Chengfu
    Zhao, Jingye
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1272 - 1278
  • [28] Intelligent calculation system for air conditioning cooling load
    2001, China Educational Publication Import and Export Corporation (34):
  • [29] Indoor thermal environment in rooms with combined air conditioning system of displacement ventilation and chilled ceiling panel
    School of Muni. and Eviron. Eng., Xi'an Univ. of Arch. and Tech, Xi'an 710055, China
    Xi'an Jianzhu Keji Daxue Xuebao, 2007, 4 (558-562):
  • [30] A novel air conditioning system - Membrane air drying and evaporative cooling
    El-Dessouky, HT
    Ettouney, HM
    Bouhamra, W
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A7): : 999 - 1009