The development of coumarin Schiff base system applied as highly selective fluorescent/colorimetric probes for Cu2+ and tumor biomarker glutathione detection

被引:0
|
作者
Wang, Zhi-Gang [1 ]
Ding, Xiao-Jing [1 ]
Huang, Yu-Ying [1 ]
Yan, Xiao-Jing [1 ]
Ding, Bin [2 ,3 ]
Li, Qing-Zhong [4 ]
Xie, Cheng-Zhi [1 ,2 ]
Xu, Jing-Yuan [1 ]
机构
[1] Tianjin Key Laboratory on Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin,300070, China
[2] Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Nankai University, Tianjin,300071, China
[3] College of Chemistry, Tianjin Normal University, Tianjin,300387, China
[4] The Laboratory of Theoretical and Computational Chemistry, School of Chemistry and Chemical Engineering, Yantai University, Yantai,264005, China
基金
中国国家自然科学基金;
关键词
Probes - Peptides - Diseases - Biomarkers - Diagnosis - Copper compounds - Tumors - Quenching - Color - Fluorescence - Light;
D O I
暂无
中图分类号
学科分类号
摘要
Overexpression of tumor biomarker glutathione (GSH) has been documented in numerous types of cancers, therefor GSH-activated light-up chemosensors for tumor identification require great attention. A new colorimetric/fluorescent probe (7-(diethylamino)-2-oxo-2H-chromen-3-yl)methylene)-4-(dimethylamino) benzohydrazide (HL) was prepared, which could be applied in discriminating Cu2+ and further recognizing GSH based on its Cu complex. Firstly, the probe HL toward Cu2+ exhibited selective fluorescence quenching and obvious color change from yellow to orange-red under visible light. Further, when GSH was introduced to the Cu2+-2HL system, the fluorescence recovered rapidly due to the high affinity of GSH to Cu2+, meanwhile the color reverted back to former yellow. Based on fluorescence titration, the detection limits were calculated as 2.40 × 10−8 M and 1.29 × 10−7 M for Cu2+ and GSH, respectively. The combination mode of HL with Cu2+ was investigated in detail by Job plots, ESI-MS, FT-IR, and DFT studies. Probes HL and Cu2+-2HL showed relatively less toxicity and were employed for biological imaging in cells and zebrafish. Remarkably, the detection for endogenous GSH by this developed sensor platform implied great potential application prospect in cancer diagnosis. © 2019
引用
收藏
相关论文
共 50 条
  • [21] Antipyrine derived Schiff's base as a colorimetric probe for the rapid and selective detection of Cu2+ ions
    Shaji, Leyana K.
    Kumar, S. K. Ashok
    INORGANIC CHEMISTRY COMMUNICATIONS, 2021, 134
  • [22] Highly sensitive and selective chemosensor for Cu2+ based on a Schiff base
    Ben-nan Cao
    Qin Hu
    Yan Huang
    Chun-man Jia
    Qi Zhang
    Chemical Research in Chinese Universities, 2013, 29 : 419 - 423
  • [23] Highly Sensitive and Selective Chemosensor for Cu2+ Based on a Schiff Base
    Cao Ben-nan
    Hu Qin
    Huang Yan
    Jia Chun-man
    Zhang Qi
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2013, 29 (03) : 419 - 423
  • [24] An ultrasensitive colorimetric and fluorescent "turn-on" chemosensor based on Schiff base for the detection of Cu2+ in the aqueous medium
    Khan, Sikandar
    Muhammad, Mian
    Kamran, Abdul Waheed
    Al-Saidi, Hamed M.
    Alharthi, Salman S.
    Algethami, Jari S.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2023, 195 (06)
  • [25] Highly selective colorimetric sensing of Cu2+ using a Schiff base derivative immobilized on polyvinyl alcohol microspheres
    Bai, Xue
    Zhang, Xudong
    Gu, Haixin
    Li, Fengjie
    Huang, Wei
    Liang, Lu
    Ye, Zhengfang
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (14) : 11682 - 11688
  • [26] An ultrasensitive colorimetric and fluorescent “turn-on” chemosensor based on Schiff base for the detection of Cu2+ in the aqueous medium
    Sikandar Khan
    Mian Muhammad
    Abdul Waheed Kamran
    Hamed M. Al-Saidi
    Salman S. Alharthi
    Jari S. Algethami
    Environmental Monitoring and Assessment, 2023, 195
  • [27] A new Schiff-base type selective fluorescent chemosensor for Cu2+
    Li, Hong-Ge
    Yang, Zheng-Yin
    Qin, Dong-Dong
    INORGANIC CHEMISTRY COMMUNICATIONS, 2009, 12 (06) : 494 - 497
  • [28] Novel coumarin-Schiff base derived electronically distinct fluorescent probes: Synthesis and comparative investigations of their unique selective sensing properties with Cu2+ and Cu+ ions
    Niranjan, Raghvendra
    Prasad, G. Durga
    Arockiaraj, Mariyaraj
    Rajeshkumar, Venkatachalam
    Mahadevegowda, Surendra H.
    JOURNAL OF MOLECULAR STRUCTURE, 2025, 1321
  • [29] A novel imidazole-derived Schiff base as selective and sensitive colorimetric chemosensor for fluorescent detection of Cu2+ in methanol with mixed aqueous medium
    Slassi, Siham
    Aarjane, Mohammed
    Amine, Amina
    APPLIED ORGANOMETALLIC CHEMISTRY, 2021, 35 (11)
  • [30] Highly sensitive and selective fluorescent sensors for the detection of Cu2+
    Madawala, Rathnayaka M.
    Sinn, Ekkehard
    Ramakrishna, Guda
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243