Crack pattern investigation of hybrid fibre reinforced concrete under uniaxial tension

被引:0
|
作者
Akçay B. [1 ]
机构
[1] Kocaeli Üniversitesi, İnşaat Mühendisliği Bölümü, Kocaeli
关键词
Crack pattern; Digital image analysis; Fibre geometry; Fibre volume; Hybrid fibre reinforced concrete; Uniaxial tensile test;
D O I
10.18400/TEKDERG.419819
中图分类号
学科分类号
摘要
The effect of size and volume of fibres on the fracture of hybrid fibre reinforced concrete was determined by applying uniaxial tensile test. The bone shaped specimens were loaded under uniaxial tension by using freely rotated support loading test setup. The test results showed that the increase in fibre volume results in an increase in both tensile strength and the area under the load displacement curve, which is the measure of the material toughness. It was shown that the use of short fibres not only increased the peak load but also affected the post-peak behaviour and increased the toughness especially when they were used together with long fibres. The image analyses pointed out that in hybrid fibre reinforced concrete the crack patterns are not in general linear. Instead, the cracks propagate inside the samples forming multiple cracks and crack branches as well as developing bridging, though these features are not observed on the surface of the samples. The results showed that with increasing amount of short fibres the average crack area was increased, while the use of long fibres in more abundance increased the width of the largest crack. © 2020 Turkish Chamber of Civil Engineers. All rights reserved.
引用
收藏
页码:9773 / 9787
页数:14
相关论文
共 50 条
  • [41] Developing an integrated technique to evaluate crack formation in reinforced concrete under uniaxial compression
    T. V. Fursa
    M. V. Petrov
    D. D. Dann
    A. E. Lykov
    Russian Journal of Nondestructive Testing, 2017, 53 : 457 - 463
  • [42] Modified the smeared crack constitutive model of fiber reinforced concrete under uniaxial loading
    Bi, Jihong
    Huo, Linying
    Zhao, Yun
    Qiao, Haoyue
    Construction and Building Materials, 2022, 250
  • [43] Developing an integrated technique to evaluate crack formation in reinforced concrete under uniaxial compression
    Fursa, T. V.
    Petrov, M. V.
    Dann, D. D.
    Lykov, A. E.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2017, 53 (06) : 457 - 463
  • [44] Tension stiffening and cracking behaviour of hybrid fibre reinforced ternary blend geopolymer concrete
    Sathish Kumar, V.
    Indira, P.V.
    Ganesan, N.
    Journal of Structural Engineering (India), 2019, 46 (04): : 257 - 266
  • [45] Thermal conductivity of hybrid fibre reinforced concrete under varying temperature
    Jeyanthi, J.
    MATERIALS TODAY-PROCEEDINGS, 2022, 64 : 598 - 604
  • [46] Modified the smeared crack constitutive model of fiber reinforced concrete under uniaxial loading
    Bi, Jihong
    Huo, Linying
    Zhao, Yun
    Qiao, Haoyue
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 250
  • [47] Microcrack characterization in concrete under uniaxial tension
    Li, ZJ
    MAGAZINE OF CONCRETE RESEARCH, 1996, 48 (176) : 219 - 228
  • [48] LOCALIZATION OF MICROCRACKING IN CONCRETE UNDER UNIAXIAL TENSION
    LI, ZJ
    SHAH, SP
    ACI MATERIALS JOURNAL, 1994, 91 (04) : 372 - 381
  • [49] Water permeability of concrete under uniaxial tension
    Yuan, Yong
    Chi, Yang
    STRUCTURAL CONCRETE, 2014, 15 (02) : 191 - 201
  • [50] Experimental investigation of reinforced concrete and hybrid fibre reinforced concrete shield tunnel segments subjected to elevated temperature
    Yan, Zhi-guo
    Shen, Yi
    Zhu, He-hua
    Li, Xiao-jun
    Lu, Yong
    FIRE SAFETY JOURNAL, 2015, 71 : 86 - 99