Assessment of 4D flow MRI for quantification of left-to-right shunt in pediatric patients with ventricular septal defect: comparison with right heart catheterization

被引:1
|
作者
Zamani-Aliabadi, Seyed Mohammad [1 ]
Qanadli, Salah D. [2 ]
Fatehi-Feyzabad, Seyed Hasan [3 ]
Ghasemnezhad, Mohsen [4 ]
Ghaemi, Hamidreza [4 ]
Azarine, Arshid [5 ]
Mohammadzadeh, Ali [3 ]
Bitarafan-Rajabi, Ahmad [1 ]
Mortezaeian, Hojjat [4 ]
Rezaei-Kalantari, Kiara [3 ]
机构
[1] Iran Univ Med Sci, Sch Med, Dept Med Phys, Tehran, Iran
[2] Lausanne Univ Hosp, Dept Diagnost & Intervent Radiol, Cardiothorac & Vasc Div, Lausanne, Switzerland
[3] Iran Univ Med Sci, Rajaie Cardiovasc & Med Res Ctr, Dept Radiol, Tehran, Iran
[4] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Dept Pediat Cardiol, Tehran, Iran
[5] Univ Paris Saclay, Hop Marie Lannelongue, Dept Radiol, Grp Hosp Paris St Joseph, Saclay, Paris, France
来源
关键词
right heart catheterization; cardiac magnetic resonance imaging; four-dimensional (4D) flow; two-dimensional (2D) flow; shunt fraction; ventricular septal defect (VSD); congenital heart disease (CHD); MAGNETIC-RESONANCE; CARDIAC-CATHETERIZATION; AMERICAN SOCIETY; BLOOD-FLOW; ECHOCARDIOGRAPHY; DISEASE; ADULT; LIMITATIONS; GUIDELINES;
D O I
10.3389/fcvm.2024.1399110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The percentage of shunt fraction significantly impacts the management of patients with congenital shunts, influencing strategic choices such as surgical or interventional procedures. This study compared the estimated shunt fraction (the ratio of pulmonary-to-systemic flow, Qp/Qs) for quantifying the left-to-right shunt in children with ventricular septal defect (VSD) using heart catheterization, four-dimensional (4D) flow, and two-dimensional (2D) flow magnetic resonance imaging (MRI). The goal was to establish a non-invasive and reliable measurement ratio between pulmonary and systemic blood flow in these patients.Methods Between July 2022 and June 2023, patients scheduled to undergo invasive right heart catheterization were included in this study. MRI was performed one hour before the catheterization procedure. The correlation of shunt fraction was assessed between all methods after calculating the Qp/Qs ratio from 2D and 4D flow MRI and catheterization.Results A total of 24 patients (aged 3-15 years, eight females) were ultimately included in the study. The Qp/Qs ratios obtained from 4D flow had a robust correlation (correlation coefficient r = 0.962) compared to those obtained during catheterization. Cardiac catheterization recorded the mean shunt fraction at 1.499 +/- 0.396, while 4D flow measured it at 1.403 +/- 0.344, with no significant difference between the two techniques. Moreover, there was a reasonable correlation (r = 0.894) between 2D flow measurements of Qp/Qs and the results obtained from catheterization, with a mean shunt fraction of 1.326 +/- 0.283.Conclusion 4D flow MRI has the potential to be a non-invasive method for accurately measuring the left-to-right shunt in children with VSD.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] DETECTION OF LEFT-TO-RIGHT SHUNT IN ATRIAL SEPTAL-DEFECT BY NEGATIVE CONTRAST ECHOCARDIOGRAPHY - A COMPARISON OF TRANSTHORACIC AND TRANSESOPHAGEAL APPROACH
    KONSTANTINIDES, S
    KASPER, W
    GEIBEL, A
    HOFMANN, T
    KOSTER, W
    JUST, H
    AMERICAN HEART JOURNAL, 1993, 126 (04) : 909 - 917
  • [32] 9 PATIENTS WITH PULMONIC STENOSIS, RIGHT-TO-LEFT SHUNT THROUGH A VENTRICULAR SEPTAL DEFECT, AND RIGHT VENTRICULAR PRESSURE ABOVE SYSTEMIC PRESSURE
    HOFFMAN, JIE
    RUDOLPH, AM
    NADAS, AS
    JOURNAL OF CLINICAL INVESTIGATION, 1959, 38 (06): : 1012 - 1012
  • [33] Quantification of left ventricular kinetic energy using 4D flow MRI
    Wåxnäs T.A.
    Heiberg E.
    Togert J.
    Larsson M.
    Arheden H.
    Carlsson M.
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [34] Large left-to-right shunts and congestive heart failure increase total energy expenditure in infants with ventricular septal defect
    Farrell, AG
    Schamberger, MS
    Olson, IL
    Leitch, CA
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (09): : 1128 - 1131
  • [35] DECREASED LEFT TO RIGHT SHUNT FLOW IN ACUTE VENTRICULAR SEPTAL-DEFECT (VSD) USING DOPAMINE AND DOBUTAMINE
    MIKELL, FL
    JORGENSEN, CR
    CARLYLE, PF
    COHN, JN
    CIRCULATION, 1979, 60 (04) : 15 - 15
  • [36] Non - invasive right ventricular efficiency using 4D flow MRI
    Alejandro Roldán-Alzate
    Scott W Grogan
    Heidi B Kellihan
    Alessandro Bellofiore
    Naomi C Chesler
    Oliver Wieben
    Christopher J Francois
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [37] Assessment of left and right atrial 3D hemodynamics in patients with atrial fibrillation: a 4D flow MRI study
    Markl, Michael
    Carr, Maria
    Ng, Jason
    Lee, Daniel C.
    Jarvis, Kelly
    Carr, James
    Goldberger, Jeffrey J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (05): : 807 - 815
  • [38] Assessment of left and right atrial 3D hemodynamics in patients with atrial fibrillation: a 4D flow MRI study
    Michael Markl
    Maria Carr
    Jason Ng
    Daniel C. Lee
    Kelly Jarvis
    James Carr
    Jeffrey J. Goldberger
    The International Journal of Cardiovascular Imaging, 2016, 32 : 807 - 815
  • [39] Relationships between Left Heart Chamber Dilatation on Echocardiography and Left-to-Right Ventricle Shunting Quantified by Cardiac Catheterization in Children with Ventricular Septal Defects
    Gokalp, Selman
    Eroglu, Ayse Guler
    Saltik, Levent
    Koca, Bulent
    PEDIATRIC CARDIOLOGY, 2014, 35 (04) : 691 - 698
  • [40] Relationships between Left Heart Chamber Dilatation on Echocardiography and Left-to-Right Ventricle Shunting Quantified by Cardiac Catheterization in Children with Ventricular Septal Defects
    Selman Gokalp
    Ayse Guler Eroglu
    Levent Saltik
    Bulent Koca
    Pediatric Cardiology, 2014, 35 : 691 - 698