The analysis of tear meniscus parameters during daily soft contact lens wear using optical coherence tomography

被引:0
|
作者
Dogan, Levent [1 ]
Arslan, Gurcan Dogukan [1 ]
机构
[1] Tatvan State Hosp, Dept Ophthalmol, Bitlis, Turkiye
关键词
Soft contact lens; Ocular discomfort; Tear meniscus; Turbidity; Optic coherence tomography; DRY EYE; OSMOLARITY; DISCOMFORT; CYTOKINES; SYMPTOMS; CORNEAL; FILM;
D O I
10.1007/s00417-024-06606-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate tear meniscus parameters in soft contact lens wearers (SCL) using optical coherence tomography (OCT) and ImageJ software. Methods This prospective study included 50 soft contact lens wearers (group 1: 25 symptomatic SCL wearers (SCLW), group 2: 25 asymptomatic SCL wearers (ASCW)) and 25 healthy non-CL wearers (group 3 (NCLW)). SCLs were fitted on each eye of CL wearers, and the lower tear meniscus was imaged using OCT before CL insertion, immediately afterward, and reimaged 2, 5 and 10 h after insertion. Tear meniscus parameters, including tear meniscus height (TMH), depth (TMD), turbidity, and percentage area occupied by particles (PAOP) were measured in all groups. Results Turbidity and PAOP measurements at baseline in SCLW were significantly higher than in other groups (p < 0.05). There was no significant difference between TMH, TMD, turbidity, and PAOP parameters calculated at baseline visit and two hours after SCL insertion in all groups (p > 0.05 for 2 comparisons). The symptomatic SCL users had a significant decrease in TMH and TMD in the fifth hour. The turbidity and PAOP measurements of SCLW and ASCW at the fifth and tenth hours were significantly higher than those of NCLW (p < 0.05). Conclusion TMD and height TMH decrease throughout the day in all participants; however, a significant decrease in these parameters was observed only in symptomatic SCL users at the fifth hour, at the earliest. As the duration of CL wear increases, turbidity and PAOP even in asymptomatic SCL wearers become significantly higher than those in healthy non-CL wearers.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 50 条
  • [21] The effect of contact lens wear on retinal spectral domain optical coherence tomography
    Aviram, Talia
    Beeri, Idan
    Berkow, David
    Zayit-Soudry, Shiri
    Blumenthal, Eytan Z.
    Shapira, Yinon
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2020, 103 (06) : 792 - 797
  • [22] Agreement and Reproducibility of Tear Meniscus Parameters determined from Spectral Domain Optical Coherence Tomography
    Nagar, Saumya
    Tepelus, Tudor
    Baghdasaryan, Elmira
    Huang, Ping
    Marion, Ken
    Lee, Susan S.
    Lee, Olivia L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [23] Tear Menisci and Ocular Discomfort during Daily Contact Lens Wear in Symptomatic Wearers
    Chen, Qi
    Wang, Jianhua
    Shen, Meixiao
    Cui, Lele
    Cai, Chunyan
    Li, Ming
    Li, Kangjun
    Lu, Fan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2175 - 2180
  • [24] Automated contact lens measurement using optical coherence tomography
    Davidson, Bryan R.
    Barton, Jennifer K.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VII, 2009, 7169
  • [25] Macular parameters with and without scleral contact lens in keratoconus using Spectralis optical coherence tomography
    Pinheiro-Costa, Joao
    Ribeiro, Margarida
    Moura, Rodolfo
    Madeira, Dulce
    Falcao-Reis, Fernando
    Carneiro, Angela
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2023, 106 (08) : 930 - 932
  • [26] Lower tear meniscus height measured by optical coherence tomography in children
    Martin-Garcia, Beatriz
    Palomo-Alvarez, Catalina
    Piedrahita-Alonso, Elena
    Gomez-de-Liano, Rosario
    Ferrer, Manuel Enrique Fuentes
    Arriola-Villalobos, Pedro
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (05) : 1059 - 1064
  • [27] Tear Meniscus Height by Optical Coherence Tomography (OCT) and Ocular Itch
    Hom, Milton M.
    Nguyen, Andrew
    Bielory, Leonard
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2013, 131 (02) : AB113 - AB113
  • [28] Interexaminer Reproducibility of Optical Coherence Tomography for Measuring the Tear Film Meniscus
    Canan, Handan
    Altan-Yaycioglu, Rana
    Ulas, Burak
    Sizmaz, Selcuk
    Coban-Karatas, Muge
    CURRENT EYE RESEARCH, 2014, 39 (12) : 1145 - 1150
  • [29] The relationship of tear osmolarity with tear meniscus curvature and contact angles in healthy subjects: anterior segment optical coherence tomography study
    Yeter, Volkan
    Kocak, Nurullah
    Kalyoncu, Merve
    Can, Ertugrul
    Ariturk, Nursen
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (01) : 261 - 268
  • [30] The relationship of tear osmolarity with tear meniscus curvature and contact angles in healthy subjects: anterior segment optical coherence tomography study
    Volkan Yeter
    Nurullah Koçak
    Merve Kalyoncu
    Ertuğrul Can
    Nurşen Arıtürk
    International Ophthalmology, 2022, 42 : 261 - 268