Fillet Radius Impact of Rectangular Insulated Wires on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors

被引:1
|
作者
Naderiallaf, Hadi [1 ]
Degano, Michele [1 ]
Gerada, Chris [1 ]
Gerada, David [1 ]
机构
[1] Univ Nottingham, Power Elect & Machines & Control PEMC Res Grp, Nottingham NG7 2RD, England
关键词
Wires; Insulation; Partial discharges; Windings; Temperature measurement; Predictive models; Permittivity measurement; Fillet radius (FR); inverter-fed machines; partial discharge inception voltage (PDIV); partial discharges (PDs); rectangular wire; VOLTAGE; AC;
D O I
10.1109/TDEI.2024.3355032
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This contribution elucidates the impact of the fillet radius (FR), a geometric feature of rectangular insulated wires not commonly considered, on the partial discharge inception voltage (PDIV) in low-voltage machine turn-to-turn winding insulation. Initial PDIV tests involve edgewise-insulated wire samples with a reference FR. These measurements are performed under constant conditions: 30 degrees C temperature, 35% relative humidity (RH), and atmospheric pressure (1000 mbar). These tests are carried out under ac 50-Hz excitations, following IEC 60034-18-41 guidelines for inverter-fed motor insulation system qualification. Subsequently, a probabilistic PDIV predictive model is developed based on Schumann's streamer inception criterion (SCSIC). This expanded model then analyzes and forecasts the impact of the FR on PDIV and its associated dispersion level, within the context of the two-parameter Weibull distribution and the given environmental conditions. Furthermore, a novel method is presented to understand partial discharge (PD) phenomenology and its destructive potential in rectangular insulated wires with varying fillet radii. This approach employs SCSIC-derived streamer inception parameters (SIPs): critical field line length (CFLL), air effective ionization coefficient (alpha(eff)), PD inception field (E-inc), and firing voltage (V-firing). The developed probabilistic predictive model enables the selection of an optimal FR value, facilitating the creation of a reliable insulation system with maximum PDIV and minimal PD-related damage.
引用
收藏
页码:2084 / 2093
页数:10
相关论文
共 31 条
  • [21] Aging Characteristics of Inter-turn Insulation of Form-wound Stator Windings of Inverter-fed AC Motors
    Zhou, Kai
    Wan, Li
    Li, Xutao
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (13) : 1280 - 1293
  • [22] Electromagnetic Radiation Characteristics of PD in Inverter-fed Motor Inter-Turn Insulation
    Ma, Shijin
    Wang, Peng
    Cheng, Chizhou
    Huang, Wendong
    2023 IEEE ELECTRICAL INSULATION CONFERENCE, EIC, 2023,
  • [23] PD Characteristics and Microscopic Analysis of Polyimide Film Used as Turn Insulation in Inverter-fed Motor
    Luo, Yang
    Wu, Guangning
    Liu, Jiwu
    Zhu, Guangya
    Wang, Peng
    Peng, Jia
    Cao, Kaijang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (05) : 2237 - 2244
  • [24] Analytical determination of the turn-to-turn capacitances of a double-layer winding considering the intermediate slider for the prediction of the potential distribution in the stator winding of inverter-fed electrical machines
    Stockbruegger, Jan Ole
    Hoffmann, Alexander
    Knebusch, Benjamin
    Dittmann, Jochen
    Ponick, Bernd
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2021, 138 (02): : 117 - 124
  • [25] High-sensitive state perception method for inverter-fed machine turn insulation based on FrFT-Mel
    Fan, Ruitian
    Lei, Xing
    Jia, Tao
    Qin, Menglong
    Li, Hao
    Xiang, Dawei
    GLOBAL ENERGY INTERCONNECTION-CHINA, 2024, 7 (02): : 155 - 165
  • [26] High-sensitive state perception method for inverter-fed machine turn insulation based on FrFT-Mel
    Ruitian Fan
    Xing Lei
    Tao Jia
    Menglong Qin
    Hao Li
    Dawei Xiang
    Global Energy Interconnection, 2024, 7 (02) : 155 - 165
  • [27] Online Monitoring of Incipient Turn Insulation Degradation for Inverter-Fed Machine Using Sensitive Tail Component in PWM Switching Oscillations
    Xiang, Dawei
    Li, Hao
    Yan, Hao
    Zheng, Yan
    Zhao, Ning
    Liu, Bowen
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (08) : 8730 - 8742
  • [28] Study on aging characteristics for inverter-fed traction Motor inter-turn insulation based on analysis of dielectric characteristic parameters
    He, Jingyan
    Wu, Guangning
    Gao, Bo
    Wu, Jiandong
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 81 - 84
  • [29] Analysis of Stator Inter-turn Short-circuit Fault Signatures for Inverter-fed Permanent Magnet Synchronous Motors
    Cira, Ferhat
    Arkan, Muslum
    Gumus, Bilal
    Goktas, Taner
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 1453 - 1457
  • [30] Analysis of steep-fronted voltage distribution and turn insulation failure in inverter-fed form-wound AC motor
    Tang, YF
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (05) : 1088 - 1096