Application of robust optimized spatiotemporal load management of data centers for renewable curtailment mitigation

被引:17
|
作者
Seyyedi, Abbas Zare Ghaleh [1 ]
Akbari, Ehsan [2 ]
Rashid, Sara Mahmoudi [3 ]
Nejati, Seyed Ashkan [4 ]
Gitizadeh, Mohsen [1 ]
机构
[1] Shiraz Univ Technol, Dept Elect & Elect Engn, Shiraz, Iran
[2] Mazandaran Univ Sci & Technol, Dept Elect Engn, Babol, Iran
[3] Univ Tabriz, Fac Elect & Comp Engn, Tabriz, Iran
[4] Newcastle Univ, Sch Engn, Newcastle Upon Tyne, England
来源
关键词
Electric power distribution; Forced curtailment of renewable energy; sources; Data centers; Data center load management; Uncertainty; Robust optimization; ENERGY; GREEN; POWER; OPERATION; COST;
D O I
10.1016/j.rser.2024.114793
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Renewable energy sources play a crucial role in the provision of power supply in active distribution networks. In networks that rely on renewable energy sources, it may become imperative to curtail the power generated by such units due to a variety of factors. The curtailment of renewable energy generation can be attributed to various factors such as overgeneration, voltage limitations at the network bus, and power limitations at the network line. As per the specified parameters, it is possible for the power generation of renewable units to exceed the load consumption at certain intervals throughout the operational duration. Hence, it is essential to devise a solution that mitigates the frequency and duration of power generation curtailments of renewable units. It is feasible to redistribute overgeneration of renewable energy sources from periods of excess to periods of insufficient capacity to meet demand. This study demonstrates that the provision of power to loads from the sub- distribution substation experiences a reduction in power supply and cost. It is feasible to transmit surplus power from a single bus to multiple other buses. The term used to refer to the ability to transfer power across different locations and time periods is known as spatiotemporal flexibility. The presence of data centers in distribution networks enables a reduction in costs and the frequency of power interruptions associated with renewable energy sources, through the utilization of spatiotemporal flexibility. The objective of this paper is to present a methodology for achieving temporal and spatial flexibility in data centers, with the aim of minimizing costs and curtailing the output generation of renewable energy units. Undoubtedly, this approach can also be executed by incorporating mobile batteries; however, it is noteworthy that mobile batteries entail additional costs on the network. Consequently, the implementation of the spatiotemporal flexibility approach in data centers has been adopted as a substitute for the utilization of mobile batteries. This approach, also referred to as virtual battery, effectively eliminates the costs associated with the use of mobile batteries. This study examines overgeneration of renewable units, bus voltage limitations, and line power restrictions on the standard IEEE 33- bus network. Three scenarios are considered, each involving changes in data center power in response to varying load profiles. The implementation of equitable power distribution across data centers, both in terms of temporal and spatial dimensions, as well as the adoption of flexible spatiotemporal flexibility scenario for data centers, have been observed. The findings of this study indicate that the approach employed in this paper leads to a decrease in costs and the output power of renewable units in the examined scenarios. The implementation of spatiotemporal flexibility mode has resulted in a reduction of power supply expenses ranging from 12 to 37 percent when compared to the basic case. Ultimately, the sensitivity analysis pertaining to the placement of data centers and the associated uncertainty index is presented.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] An optimized load-balancing scheduling method based on the WLC algorithm for cloud data centers
    Zhou, Lianying
    Cui, Xingping
    Wu, Shuyue
    Journal of Computational Information Systems, 2013, 9 (17): : 6819 - 6829
  • [22] Novel Renewable Energy Source in Standalone Microgrid Application with Island Load Management
    Teke M.
    Yatak M.Ö.
    Yaseen E.S.Y.
    Electronics, 2023, 27 (01) : 3 - 8
  • [23] Energy-efficient Management of Data Centers using a Renewable-aware Scheduler
    Peng, Xiaopu
    Bhattacharya, Tathagata
    Mao, Jianzhou
    Cao, Ting
    Jiang, Chao
    Qin, Xiao
    2022 IEEE INTERNATIONAL CONFERENCE ON NETWORKING, ARCHITECTURE AND STORAGE (NAS), 2022, : 133 - 140
  • [24] Integrated Management of Application Performance, Power and Cooling in Data Centers
    Chen, Yuan
    Gmach, Daniel
    Hyser, Chris
    Wang, Zhikui
    Bash, Cullen
    Hoover, Christopher
    Singhal, Sharad
    PROCEEDINGS OF THE 2010 IEEE-IFIP NETWORK OPERATIONS AND MANAGEMENT SYMPOSIUM, 2010, : 615 - 622
  • [25] Spatio-temporal load migration potential of data centers: Evaluation and application
    Zhu, Lei
    Wu, Shutan
    Liu, Haoyu
    Wang, Qi
    Tang, Yi
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [26] Energy-Efficient Task Scheduling for Data Centers with Unstable Renewable Energy: A Robust Optimization Approach
    Lu, Yiwen
    Wang, Ran
    Wang, Ping
    Cao, Yue
    Hao, Jie
    Zhu, Kun
    IEEE 2018 INTERNATIONAL CONGRESS ON CYBERMATICS / 2018 IEEE CONFERENCES ON INTERNET OF THINGS, GREEN COMPUTING AND COMMUNICATIONS, CYBER, PHYSICAL AND SOCIAL COMPUTING, SMART DATA, BLOCKCHAIN, COMPUTER AND INFORMATION TECHNOLOGY, 2018, : 455 - 462
  • [27] A Robust Algorithm for Capacity Management to Improve Response Time in Virtualized Data Centers
    Vishwakarma, Murli Manohar
    Manoria, Manish
    2015 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMMUNICATION NETWORKS (CICN), 2015, : 731 - 735
  • [28] AutoScale: Dynamic, Robust Capacity Management for Multi-Tier Data Centers
    Gandhi, Anshul
    Harchol-Balter, Mor
    Raghunathan, Ram
    Kozuch, Michael A.
    ACM TRANSACTIONS ON COMPUTER SYSTEMS, 2012, 30 (04):
  • [29] Robust Demand-side Plug-in Electric Vehicle Load Control for Renewable Energy Management
    Bashash, Saeid
    Fathy, Hosam K.
    2011 AMERICAN CONTROL CONFERENCE, 2011, : 929 - 934
  • [30] Spatio-temporal management of renewable energy consumption, carbon emissions, and cost in data centers
    Chen, Donglin
    Ma, Yifan
    Wang, Lei
    Yao, Mengdi
    SUSTAINABLE COMPUTING-INFORMATICS & SYSTEMS, 2024, 41