Application of robust optimized spatiotemporal load management of data centers for renewable curtailment mitigation

被引:17
|
作者
Seyyedi, Abbas Zare Ghaleh [1 ]
Akbari, Ehsan [2 ]
Rashid, Sara Mahmoudi [3 ]
Nejati, Seyed Ashkan [4 ]
Gitizadeh, Mohsen [1 ]
机构
[1] Shiraz Univ Technol, Dept Elect & Elect Engn, Shiraz, Iran
[2] Mazandaran Univ Sci & Technol, Dept Elect Engn, Babol, Iran
[3] Univ Tabriz, Fac Elect & Comp Engn, Tabriz, Iran
[4] Newcastle Univ, Sch Engn, Newcastle Upon Tyne, England
来源
关键词
Electric power distribution; Forced curtailment of renewable energy; sources; Data centers; Data center load management; Uncertainty; Robust optimization; ENERGY; GREEN; POWER; OPERATION; COST;
D O I
10.1016/j.rser.2024.114793
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Renewable energy sources play a crucial role in the provision of power supply in active distribution networks. In networks that rely on renewable energy sources, it may become imperative to curtail the power generated by such units due to a variety of factors. The curtailment of renewable energy generation can be attributed to various factors such as overgeneration, voltage limitations at the network bus, and power limitations at the network line. As per the specified parameters, it is possible for the power generation of renewable units to exceed the load consumption at certain intervals throughout the operational duration. Hence, it is essential to devise a solution that mitigates the frequency and duration of power generation curtailments of renewable units. It is feasible to redistribute overgeneration of renewable energy sources from periods of excess to periods of insufficient capacity to meet demand. This study demonstrates that the provision of power to loads from the sub- distribution substation experiences a reduction in power supply and cost. It is feasible to transmit surplus power from a single bus to multiple other buses. The term used to refer to the ability to transfer power across different locations and time periods is known as spatiotemporal flexibility. The presence of data centers in distribution networks enables a reduction in costs and the frequency of power interruptions associated with renewable energy sources, through the utilization of spatiotemporal flexibility. The objective of this paper is to present a methodology for achieving temporal and spatial flexibility in data centers, with the aim of minimizing costs and curtailing the output generation of renewable energy units. Undoubtedly, this approach can also be executed by incorporating mobile batteries; however, it is noteworthy that mobile batteries entail additional costs on the network. Consequently, the implementation of the spatiotemporal flexibility approach in data centers has been adopted as a substitute for the utilization of mobile batteries. This approach, also referred to as virtual battery, effectively eliminates the costs associated with the use of mobile batteries. This study examines overgeneration of renewable units, bus voltage limitations, and line power restrictions on the standard IEEE 33- bus network. Three scenarios are considered, each involving changes in data center power in response to varying load profiles. The implementation of equitable power distribution across data centers, both in terms of temporal and spatial dimensions, as well as the adoption of flexible spatiotemporal flexibility scenario for data centers, have been observed. The findings of this study indicate that the approach employed in this paper leads to a decrease in costs and the output power of renewable units in the examined scenarios. The implementation of spatiotemporal flexibility mode has resulted in a reduction of power supply expenses ranging from 12 to 37 percent when compared to the basic case. Ultimately, the sensitivity analysis pertaining to the placement of data centers and the associated uncertainty index is presented.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Mitigating Curtailment and Carbon Emissions through Load Migration between Data Centers
    Zheng, Jiajia
    Chien, Andrew A.
    Suh, Sangwon
    JOULE, 2020, 4 (10) : 2208 - 2222
  • [2] Optimized Renewable Energy Use in Green Cloud Data Centers
    Xu, Minxian
    Toosi, Adel N.
    Bahrani, Behrooz
    Razzaghi, Reza
    Singh, Martin
    SERVICE-ORIENTED COMPUTING (ICSOC 2019), 2019, 11895 : 314 - 330
  • [3] ROBUST GEOGRAPHICAL LOAD BALANCING FOR SUSTAINABLE DATA CENTERS
    Chen, Tianyi
    Zhang, Yu
    Wang, Xin
    Giannakis, Georgios B.
    2016 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING PROCEEDINGS, 2016, : 3526 - 3530
  • [4] Robust Energy Management of Microgrid With Uncertain Renewable Generation and Load
    Xiang, Yue
    Liu, Junyong
    Liu, Yilu
    IEEE TRANSACTIONS ON SMART GRID, 2016, 7 (02) : 1034 - 1043
  • [5] Adaptive memory load management in cloud data centers
    Wu, H.
    Tantawi, A. N.
    Diao, Y.
    Wang, W.
    IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 2011, 55 (06)
  • [6] Load Management of Data Centers as Regulation Capacity in Denmark
    Clausen, Anders
    Ghatikar, Girish
    Jorgensen, Bo Norregaard
    2014 INTERNATIONAL GREEN COMPUTING CONFERENCE (IGCC), 2014,
  • [7] Robust Workload and Energy Management for Sustainable Data Centers
    Chen, Tianyi
    Zhang, Yu
    Wang, Xin
    Giannakis, Georgios B.
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2016, 34 (03) : 651 - 664
  • [8] Carbon-Aware Load Balance Control of Data Centers With Renewable Generations
    Lin, Wen-Ting
    Chen, Guo
    Li, Huaqing
    IEEE TRANSACTIONS ON CLOUD COMPUTING, 2023, 11 (02) : 1111 - 1121
  • [9] Adaptive Robust Optimization for Coordinated Capacity and Load Control in Data Centers
    Yin, Xiaoqi
    Sinopoli, Bruno
    2014 IEEE 53RD ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), 2014, : 5674 - 5679
  • [10] Coordinated Planning of Multiple Energy Hubs Considering the Spatiotemporal Load Regulation of Data Centers
    Zhang, Shenxi
    Lyu, Jiawei
    Jin, Wenguang
    Cheng, Haozhong
    Li, Canbing
    Wang, Xu
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2024, 39 (02) : 4193 - 4207