Lightning Current Measurement Method Using Rogowski Coil Based on Integral Circuit with Low-Frequency Attenuation Feedback

被引:0
|
作者
Xiao, Yiping [1 ,2 ]
Jiao, Hongjian [1 ]
Huo, Feng [3 ]
Shen, Zongtao [1 ]
机构
[1] Hubei Univ Technol, Sch Elect & Elect Engn, Wuhan 430068, Peoples R China
[2] Hubei Univ Technol, Hubei Key Lab High Efficiency Utilizat Solar Energ, Wuhan 430068, Peoples R China
[3] China Elect Power Res Inst Co Ltd, Wuhan 43007, Peoples R China
关键词
Rogowski coil; lightning current measurement; low-frequency distortion; integral correction; low-frequency attenuation feedback network; CURRENT SENSOR;
D O I
10.3390/s24154980
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A lightning current measurement method using a Rogowski coil based on an integral circuit with low-frequency attenuation feedback was proposed to address the issue of low-frequency distortion in the measurement of lightning currents on transmission lines using Rogowski coils. Firstly, the causes of low-frequency distortion in lightning current measurements using Rogowski coils were analyzed from the perspective of frequency domains. On this basis, an integration correction optimization circuit with a low-frequency attenuation feedback network was designed to correct the low-frequency distortion. The optimized integration circuit can also reduce the impact of low-frequency noise and the DC bias of the operational amplifier (op-amp) on the integration circuit due to the high low-frequency gain. Additionally, a high-pass filtering and voltage-divided sampling circuit has been added to ensure the normal operation of the integrator and improve the measurement range of the measurement system. Then, according to the relationship between the amplitude-frequency characteristics of the measurement system and the parameters of each component, the appropriate types of components and op-amp were selected to expand the measurement bandwidth. Finally, a simulation verification was conducted, and the simulation results show that this measurement method can effectively expand the lower measurement frequency limit to 20 Hz, correct the low-frequency distortion caused by Rogowski coils measuring lightning currents on transmission lines, and accurately restore the measured lightning current waveform.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Magnetometer Using Inductance Modulation of High-Critical-Temperature Superconducting Coil for Low-Frequency Field Measurement in Presence of Excitation Fields
    Enpuku, Keiji
    Matsuo, Masaaki
    Yoshida, Yujiro
    Yamashita, Shigeya
    Sasayama, Teruyoshi
    Yoshida, Takashi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (05)
  • [42] A digital low-frequency geophone based on 4th-order sigma-delta modulator and single-coil velocity feedback
    Zhang, Xiaopeng
    Wei, Xueyong
    Wang, Tongdong
    Li, Xin
    Xiao, Weiguo
    Wu, Zutang
    SENSORS AND ACTUATORS A-PHYSICAL, 2020, 312
  • [43] Localising low-level short-circuit faults on the windings of power transformers based on low-frequency response measurement of the transformer windings
    Mahvi, Mojtaba
    Behjat, Vahid
    IET ELECTRIC POWER APPLICATIONS, 2015, 9 (08) : 533 - 539
  • [44] Low-frequency oscillation suppression using flexible DC grid based on state feedback supplementary damping control
    Ni B.
    Xiang W.
    Lu X.
    Wen J.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (03): : 45 - 50and57
  • [45] Desert Seismic Low-Frequency Noise Attenuation Using Low-Rank Decomposition-Based Denoising Convolutional Neural Network
    Ma, Haitao
    Wang, Yuzhuo
    Li, Yue
    Zhao, Yuxing
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [46] Measurement of low-frequency base and collector current noise and coherence in SiGe heterojunction bipolar transistors using transimpedance amplifiers
    Bruce, SPO
    Vandamme, LKJ
    Rydberg, A
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1999, 46 (05) : 993 - 1000
  • [47] A stress defect state measurement method based on low-frequency ACMFL excitation and Hall sensor array collection
    Zhang, ShaoXuan
    Feng, Jian
    Lu, Senxiang
    Dong, Xu
    Zhang, Xinbo
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (08)
  • [48] Novel PMD measurement method based on OFDR using a frequency-shifted feedback fiber laser
    Yoshida, M
    Miyamoto, T
    Zou, NY
    Nakamura, K
    Ito, H
    OPTICS EXPRESS, 2001, 9 (04): : 207 - 211
  • [49] Methodology for Extracting Low-Frequency Input Impedance of Personal Computer During Operation Using Dual Current Probes Method
    Rhee, Jaewon
    Kim, Hyunwoong
    Chu, Kwanguk
    Ahn, Seungyoung
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2024, 66 (02) : 584 - 598
  • [50] Analysis of Low-frequency Dielectric Loss Characteristics of Oil-paper Insulation Based on Polarization and Depolarization Current Method
    Zhou K.
    Li M.
    Rao X.
    Chen S.
    Li, Mingzhi (daniellee66@163.com), 1600, Science Press (46): : 2830 - 2838