Impact of overweight and obesity on radiation dose and outcome in patients undergoing pulmonary vein isolation by cryoballoon and pulsed field ablation

被引:0
|
作者
Jungen, Christiane [1 ]
Rattka, Manuel [2 ]
Bohnen, Jan [1 ]
Mavrakis, Evangelos [1 ]
Vlachopoulou, Dimitra [1 ]
Dorna, Sebastian [1 ]
Rudolph, Isabel [2 ]
Kohn, Christina [1 ]
Dobrev, Dobromir [3 ,4 ,5 ,6 ]
Rassaf, Tienush [1 ]
Mathew, Shibu [1 ]
机构
[1] Univ Duisburg Essen, West German Heart & Vasc Ctr Essen, Dept Cardiol & Vasc Med, Essen, Germany
[2] Tech Univ Munich, Univ Med Ctr, Dept Clin Med, Clin Dept Cardiol, Munich, Germany
[3] Univ Duisburg Essen, Inst Pharmacol, Fac Med, Essen, Germany
[4] Baylor Coll Med, Dept Integrat Physiol, Houston, TX USA
[5] Montreal Heart Inst, Dept Med, Montreal, PQ, Canada
[6] Univ Montreal, Montreal, PQ, Canada
来源
IJC HEART & VASCULATURE | 2024年 / 55卷
关键词
Pulmonary vein isolation; Pulsed field ablation; Obesity; Catheter ablation; Atrial fibrillation; ATRIAL-FIBRILLATION; INTERVENTIONAL CARDIOLOGISTS; WEIGHT;
D O I
10.1016/j.ijcha.2024.101516
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pulmonary vein isolation (PVI) using pulsed field ablation (PFA) or cryoballoon ablation (CBA) are commonly used single-shot techniques for the treatment of patients with atrial fibrillation (AF). The number of overweight (BMI 25-30 kg/m(2)) and obese (BMI>30 kg/m(2)) patients undergoing PVI is increasing, but data on this patient population is limited. Methods: Consecutive AF patients with a BMI >= 25 kg/m(2) undergoing PFA- or CBA-PVI were included in this retrospective analysis. Baseline characteristics, procedural parameters and 1-year AF-freedom were retrospectively analyzed and compared for both ablation modalities. Results: Of 115 patients (66 % men, 64 years [IQR: 58-71 years], 57 % overweight and 43 % obese) PFA- was performed in 68 % and CBA-PVI in 32 %. Contrast-dye volume (PFA: 80 ml [IQR: 60 - 117 ml] vs. CBA: 130 ml [IQR: 95 - 200 ml], P=0.001) and radiation exposure (PFA: 2196 cGy<middle dot>cm(2) [IQR: 1398 - 2973 cGy<middle dot>cm(2)] vs. CBA: 3239 cGy<middle dot>cm(2) [IQR: 1288 - 5062 cGy<middle dot>cm(2)], P=0.009) was lower in patients undergoing PFA-PVI. Logistic regression analysis identified obesity (OR: 5.58, 95 % CI: 1.63-19.06; P=0.006) and CBA-PVI (OR: 12.93, 95 % CI: 3.51-47.68; P<bold><</bold>0.001) to be associated with increased radiation exposure. Both techniques were comparably safe (PFA: 4 % vs. CBA: 0 %; P=0.3). The median follow-up time was 145 days [IQR: 103 - 294 days]. AF-freedom after 1-year was similar in overweight (82 %) and obese patients (67 %) (HR: 0.61; 95 % CI: 0.29-1.28; P=0.19) as well as in PFA- and CBA-PVI patients (76 % vs. 76 %, HR: 1.37; 95 % CI: 0.63-2.99; P=0.42). Conclusion: Overweight and obese patients undergoing PFA-PVI had lower contrast-dye volume compared to CBA-PVI. Obesity was associated with increased radiation exposure. Both techniques were comparably safe. The 1-year AF-freedom was similar in overweight and obese patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Impact of Pulmonary Vein Anatomy on Long-term Outcome of Cryoballoon Ablation for Atrial Fibrillation
    Shang-wei Huang
    Qi Jin
    Ning Zhang
    Tian-you Ling
    Wen-qi Pan
    Chang-jian Lin
    Qing-zhi Luo
    Yan-xin Han
    Li-qun Wu
    Current Medical Science, 2018, 38 : 259 - 267
  • [32] Pulmonary vein isolation with biphasic pulsed field ablation: A preclinical comparison with irrigated radiofrequency ablation
    Kuroki, Kenji
    Koruth, Jacob
    Iwasawa, Jin
    Buck, Eric
    Viswanathan, Raju
    Brose, Richard
    Dukkipati, Srinivas
    Whang, William
    Choudry, Subbarao
    Miller, Marc
    Sofi, Aamir
    Langan, Marie
    Gomez, Anthoniy
    Neuzil, Petr
    Reddy, Vivek
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1742 - 1742
  • [33] Atrioventricular conduction disturbance during pulmonary vein isolation using the second-generation cryoballoon - Vagal impact of cryoballoon ablation
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Watanabe, Tomonori
    Hada, Masahiro
    Yamao, Kazuya
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Tada, Hiroshi
    Hirao, Kenzo
    Iesaka, Yoshito
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 265 : 113 - 117
  • [34] Pulmonary vein isolation in patients with a left common pulmonary vein: Comparison between second-generation cryoballoon and radiofrequency ablation
    Yamaguchi, Masao
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Hada, Masahiro
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Iesaka, Yoshito
    JOURNAL OF CARDIOLOGY, 2019, 73 (3-4) : 292 - 298
  • [35] Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoon
    Aytemir, Kudret
    Gurses, Kadri Murat
    Yalcin, Muhammed Ulvi
    Kocyigit, Duygu
    Dural, Muhammet
    Evranos, Banu
    Yorgun, Hikmet
    Ates, Ahmet Hakan
    Sahiner, Mehmet Levent
    Kaya, Ergun Bans
    Oto, Mehmet Ali
    EUROPACE, 2015, 17 (03): : 379 - 387
  • [36] Impact of Pulsed-Field Ablation on Intrinsic Cardiac Autonomic Nervous System After Pulmonary Vein Isolation
    Tohoku, Shota
    Schmidt, Boris
    Schaack, David
    Bordignon, Stefano
    Hirokami, Jun
    Chen, Shaojie
    Ebrahimi, Ramin
    Efe, Tolga Han
    Urbanek, Lukas
    Chun, K. R. Julian
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (09) : 1864 - 1875
  • [37] LA strain analysis in patients undergoing atrial fibrillation ablation using cryoballoon or pulsed-field-ablation
    Jungen, C.
    Eitel, C.
    Mavrakis, E.
    Vlachopoulo, D.
    Rudolph, I
    Bohnen, J.
    Rattka, M.
    Rassaf, T.
    Mathew, S.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [38] Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome
    Van Belle, Yves
    Janse, Petter
    Rivero-Ayerza, Maximo J.
    Thornton, Andrew S.
    Jessurun, Emile R.
    Theuns, Dominic
    Jordaens, Luc
    EUROPEAN HEART JOURNAL, 2007, 28 (18) : 2231 - 2237
  • [39] Effectiveness of Simple Pulmonary Vein Isolation using Cryoballoon Ablation in Patients with Persistent Atrial Fibrillation. -A Comparison with Pulmonary Vein Antrum Isolation using Radiofrequency Catheter Ablation
    Tokano, Takashi
    Shiozawa, Tomoyuki
    Kimura, Yuki
    Odagiri, Fuminori
    Tabuchi, Haruna
    Hayuashi, Hidemori
    Sekita, Gaku
    Sumiyoshi, Masataka
    Nakazato, Yuji
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (03) : 789 - 789
  • [40] Pulsed-field ablation for pulmonary vein isolation in humans: Endoscopic observations of the esophagus
    Neuzil, Petr
    Petru, Jan
    Funosako, Moritoshi
    Chovanec, Milan
    Kralovec, Stepan
    Kuroki, Kenji
    Koruth, Jacob
    Pare, Michael
    Schneider, Christopher
    Eggert, Charles
    Reddy, Vivek
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1750 - 1750